R Wave Sensing After VT Ablation (RASA-VT)

18 de diciembre de 2018 actualizado por: Ivan Zeljkovic, University Hospital "Sestre Milosrdnice"

R Wave Sensing After Radiofrequency Ablation of Ventricular Tachycardia Substrate in Patients With Structural Heart Disease

Sustained, monomorphic ventricular tachycardia (VT) is most commonly encountered in patients with structural heart disease, usually with ischemic aetiology. It has been proven that repeated episodes of sustained VT contribute to the mortality of patients with structural heart disease. These patients are usually implanted with implantable cardioverter defibrillator without (ICD) or with cardiac resynchronisation therapy (CRT-D). According to the current guidelines 3D mapping with radiofrequency (RF) ablation of the tachycardia substrate is an established therapeutic option. As part of the clinical follow-up of patients implanted with cardiac implantable electronic devices (CIED), CIED function parameters are monitored every 6 months, which is always done before and after any procedure involving RF ablation. Furthermore, a transient drop of R wave sensing has been demonstrated after the atrioventricular (AV) node ablation in patients with single-chamber pacemakers and fast atrial fibrillation. The aim of this study is to assess the change in R wave sensing after the RF ablation of VT substrate.

This study will be performed as a clinical, prospective, multi-centre, observational cohort study with a structured follow-up period of 12 months. All consecutive patients with sustained VT implanted with ICD or CRT-D undergoing RF ablation procedure of myocardial substrate, who are able to understand and sign informed consent, will be enrolled. Primary objective is a R wave sensing drop > 30% after VT substrate ablation procedure. Recruiting should not exceed 12 months with the minimal follow-up period of 12 months (24 months in total). Standardized statistical methods and test will be done using SPSS Software Version 22.0 or newer.

This unique study offers the possibility to show the impact of RF ablation on short-term and long-term R wave sensing change assessed by ICD or CRT-D's ventricle electrode in patients with sustained VT and structural heart disease undergoing ablation procedure. This observational data is needed to further refine the treatment of these patients and to prevent possible ICD/CRT-D dysfunction which could endanger this patient population.

Descripción general del estudio

Descripción detallada

Sustained, monomorphic ventricular tachycardia (VT) is most commonly encountered in patients with structural heart disease, usually with ischemic aetiology. It has been proven that repeated episodes of sustained VT contribute to the mortality of patients with structural heart disease. These patients are usually implanted with implantable cardioverter defibrillator without (ICD) or with cardiac resynchronisation therapy (CRT-D) as part of sudden cardiac death (SCD) prevention and have had activation of the device due to the sustained VT episodes. According to the current guidelines 3D mapping with radiofrequency (RF) ablation of the tachycardia substrate is an established therapeutic option. As part of the clinical follow-up of patients implanted with cardiac implantable electronic devices (CIED), including ICDs and CRT-Ds, function parameters are monitored every 6 months. The same check-up is done before and after any procedure involving RF ablation. Furthermore, a transient drop of R wave sensing has been demonstrated after the RF ablation of the atrioventricular (AV) node in patients with uncontrollable fast atrial fibrillation implanted with single-chamber pacemakers. The above mentioned have not been studied yet in patients ablated due to sustained VT. Hence, the aim of this study is to assess the change in R wave sensing after the RF ablation of VT substrate in patients with structural heart disease.

This study will be performed as a clinical, prospective, multi-centre, observational (analytic, longitudinal) cohort study with patient enrolment in 4 electrophysiology centres in Croatia and Switzerland and a structured follow-up period of 12 months.

All consecutive patients with sustained VT implanted with ICD or CRT-D undergoing RF ablation procedure of myocardial substrate, who are able to understand and sign informed consent, will be enrolled.

Exclusion criteria:

  • Patients with combined mechanical aortic and mitral valve prostheses
  • Patients with RF ablation of VT done in the last 12 months
  • Patients with known damaged ICD/CRT-D electrode or battery
  • Patients undergoing VT ablation who have not been implanted with ICD or CRT-D
  • Patients not willing or able to undergo clinical follow-up of ICD/CRT-D device
  • Patients with life expectancy < 1 year
  • Not able to understand or willing to sign informed consent
  • Age < 18 years Primary objective is a R wave sensing drop > 30% after VT substrate ablation procedure.

Specific (secondary) end-points:

  • incidence of VT recurrence after the ablation procedure;
  • risk factors for R wave sensing drop (> 30%) after the RF ablation of VT substrate;
  • time needed for R wave sensing recovery after the RF ablation procedure. Recruiting should not exceed 12 months with the minimal follow-up period of 12 months (24 months in total).

The risk categorisation of the study was done and the study was awarded a risk category A.

Sample size was chosen according to annual procedure volumes in Croatia and Switzerland. In addition, it is confirmed by power test (number needed to recruit: 52). Recruiting should not exceed 12 months. Categorical variables will be presented by contingency tables in absolute values and percentages. Categorical variables will be compared by the chi-square with Yates corrections or Fisher's exact test. Continuous data will be expressed as means and standard deviations or median with corresponding interquartile range. The differences in quantitative variables will be tested by Mann-Whitney U-test (non-parametric test for independent samples). Logistic regression will be used to analyse the association between all variables of interest and the R wave sensing drop. Multivariate logistic regression will be used to adjust for confounding factors. Predictors of the R wave sensing drop will be assessed in a univariate and multivariate Cox proportional hazards model. The statistical analysis will be done using SPSS Software Version 22.0 or newer (IBM SPSS Statistics, New York, USA).

This unique study offers the possibility to show the impact of RF ablation on short-term and long-term R wave sensing change assessed by ICD or CRT-D's ventricle electrode in patients with sustained VT and structural heart disease undergoing ablation procedure. This observational data is needed to further refine the treatment of these patients and to prevent possible ICD/CRT-D dysfunction which could endanger this patient population. Despite a high number of cohort registries for cardiovascular diseases (e.g. Danish heart registry, ORBIT-AF, GARFIELD AF registry, Swiss AF registry), there are scarce data on patients with structural VT and no data regarding R wave sensing changes influenced by RF energy application in ventricles. In addition, this could influence obligatory rhythm-monitoring duration and consequently hospitalization duration of patients with VT undergoing RF ablation procedures. Apart from the above mentioned, in those patients with non-optimal preprocedural R wave sensing, this could mean contraindication for procedure or having the need to do postprocedural defibrillation testing. It is likely, that data from our study will lead to future changes in periprocedural planning and modalities.

This study will be conducted in compliance with the current version of the Declaration of Helsinki, the ICH-GCP or ISO EN 14155 (as far as applicable) as well as all national legal and regulatory requirements. According to ethical regulations, the study plan with the proposed participant information and consent form as well as other project-specific documents will be submitted to Ethic committee of the participating centres.

Tipo de estudio

De observación

Inscripción (Anticipado)

100

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Rijeka, Croacia, 51000
        • University Hospital Rijeka
      • Zagreb, Croacia, 10000
        • University Hospital Sestre Milosrdnice
      • Basel, Suiza, 4031
        • University Hospital Basel
      • Bern, Suiza, 3012
        • University Hospital Bern

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Método de muestreo

Muestra no probabilística

Población de estudio

Patients with structural heart disease (ischemic and non-ischemic aetiology) implanted with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy cardioverter defibrillator (CRT-D) and recurrent, sustained, monomorphic ventricular tachycardia, who are, according to their cardiologist, planned for 3D mapping and radiofrequency ablation of ventricular tachycardia myocardial substrate.

Descripción

Inclusion Criteria:

  • patients with recurrent, sustained ventricular tachycardia
  • patients implanted with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy cardioverter defibrillator (CRT-D)
  • patients planned for 3D mapping and radiofrequency ablation of ventricular tachycardia myocardial substrate
  • patients who are able to understand and sign informed consent

Exclusion Criteria:

  • Patients with combined mechanical aortic and mitral valve prostheses
  • Patients with RF ablation of VT done in the last 12 months
  • Patients with known damaged ICD/CRT-D electrode or battery
  • Patients undergoing VT ablation who have not been implanted with ICD or CRT-D
  • Patients not willing or able to undergo clinical follow-up of ICD/CRT-D device
  • Patients with life expectancy < 1 year
  • Not able to understand or willing to sign informed consent
  • Age < 18 years

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
R wave sensing change
Periodo de tiempo: immediately after the ablation procedure
R wave sensing drop > 30% after RF ablation of VT substrate in left and/or right ventricle assessed by ventricular electrode of the CIED
immediately after the ablation procedure

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
R wave sensing change 24h follow-up
Periodo de tiempo: 24 hours after ablation procedure
R wave sensing drop > 30% after RF ablation of VT substrate in left and/or right ventricle assessed by ventricular electrode of the CIED
24 hours after ablation procedure
R wave sensing change 3-6 month follow-up
Periodo de tiempo: 3-6 months after ablation procedure
R wave sensing drop > 30% after RF ablation of VT substrate in left and/or right ventricle assessed by ventricular electrode of the CIED
3-6 months after ablation procedure
R wave sensing change 9-12 month follow-up
Periodo de tiempo: 9-12 months after the ablation procedure
R wave sensing drop > 30% after RF ablation of VT substrate in left and/or right ventricle assessed by ventricular electrode of the CIED
9-12 months after the ablation procedure
Incidence of VT recurrence after the ablation procedure
Periodo de tiempo: 12 months after the ablation procedure
Assessing the VT recurrence after the ablation procedure by ICD or CRT-D interrogation adn function testing
12 months after the ablation procedure
Risk factors for R wave sensing change after the RF ablation of VT substrate
Periodo de tiempo: 12 months
assessing risk factors for R wave sensing drop after the RF ablation of VT substrate
12 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Investigador principal: Ivan Zeljkovic, MD, University Hospital "Sestre Milosrdnice"

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Anticipado)

1 de diciembre de 2018

Finalización primaria (Anticipado)

1 de diciembre de 2019

Finalización del estudio (Anticipado)

1 de diciembre de 2020

Fechas de registro del estudio

Enviado por primera vez

17 de diciembre de 2018

Primero enviado que cumplió con los criterios de control de calidad

17 de diciembre de 2018

Publicado por primera vez (Actual)

19 de diciembre de 2018

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

20 de diciembre de 2018

Última actualización enviada que cumplió con los criterios de control de calidad

18 de diciembre de 2018

Última verificación

1 de diciembre de 2018

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • ZAPSA01
  • UTN U1111-1223-2331 (Otro identificador: Universal Trial Number - World Health Organization)

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir