Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Comparison of a Short Modified Metal Stent Versus Plastic Stent as a Bridge to Surgery in Pancreatic Cancer With Malignant Biliary Obstruction (BRIDGE-8)

18 de mayo de 2026 actualizado por: Il Sang Shin, Soonchunhyang University Hospital

Multicenter Randomized Trial of a Short Modified 8-mm-diameter Fully Covered Metal Stent Versus Plastic Stent as a Bridge to Surgery in Pancreatic Cancer With Malignant Biliary Obstruction

This study is a multicenter, randomized clinical trial designed to compare the effectiveness and safety of a modified 8-mm fully covered self-expandable metal stent (FCSEMS) with a conventional plastic stent for preoperative biliary drainage in patients with pancreatic cancer and malignant biliary obstruction.

In patients who require biliary drainage before surgery, stent placement is commonly performed using endoscopic retrograde cholangiopancreatography (ERCP). However, the optimal stent type remains uncertain.

Participants will be randomly assigned to receive either the modified FCSEMS or a plastic stent. The primary objective is to evaluate the rate of stent-related complications requiring reintervention before surgery. Secondary outcomes include stent patency, adverse events, and surgical outcomes.

The results of this study are expected to help determine the most appropriate stent strategy for patients undergoing surgery for pancreatic cancer.

Descripción general del estudio

Descripción detallada

Pancreatic cancer is a highly aggressive malignancy with a poor prognosis, and many patients present with malignant biliary obstruction at the time of diagnosis. Preoperative biliary drainage is frequently required in patients undergoing neoadjuvant chemotherapy or delayed surgery to relieve jaundice and prevent complications such as cholangitis.

Endoscopic retrograde cholangiopancreatography (ERCP) with stent placement is the standard approach for biliary drainage. Plastic stents (PS) are widely used due to their low cost and ease of removal; however, they are associated with a relatively short patency and frequent occlusion, often necessitating repeated interventions. Fully covered self-expandable metal stents (FCSEMS) have demonstrated longer patency, but concerns remain regarding adverse events and potential impact on subsequent surgical procedures.

A modified non-flared 8-mm diameter FCSEMS has been developed to reduce complications while maintaining adequate patency. Its design includes a dumbbell-shaped structure with a narrower central portion to prevent migration, a fully covered membrane to reduce tissue ingrowth, and a retrieval lasso to facilitate removal. This design may offer advantages over both conventional FCSEMS and plastic stents in the preoperative setting.

This study is a prospective, multicenter, open-label, randomized controlled trial designed to compare a modified 8-mm FCSEMS with a plastic stent for preoperative biliary drainage in patients with pancreatic cancer and malignant biliary obstruction. Eligible patients will be randomly assigned in a 1:1 ratio to receive either the modified FCSEMS or a plastic stent.

The primary endpoint is the stent-related non-event rate at the time of surgery, defined as the proportion of patients who do not require reintervention due to stent-related complications before surgery. Secondary endpoints include the incidence of recurrent biliary obstruction, time to recurrent biliary obstruction, stent-related adverse events, technical success, surgical outcomes, and overall survival.

All procedures will be performed using standard ERCP techniques by experienced endoscopists. Patients will be followed until surgery and throughout the postoperative period to assess clinical outcomes.

The findings of this study are expected to provide evidence to guide optimal stent selection for preoperative biliary drainage in patients with pancreatic cancer, particularly in the context of neoadjuvant treatment strategies.

Tipo de estudio

Intervencionista

Inscripción (Estimado)

116

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

  • Nombre: Il Sang Shin, Assistant Professor
  • Número de teléfono: +82-10-4658-8794
  • Correo electrónico: ilsang.shin@schmc.ac.kr

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria:

  1. Age ≥ 18 years
  2. Patients with resectable, borderline resectable, or locally advanced pancreatic cancer with distal malignant biliary obstruction requiring endoscopic biliary drainage
  3. Biliary stricture located ≥ 2 cm below the hepatic hilum
  4. Serum bilirubin ≥ 3 mg/dL
  5. Eastern Cooperative Oncology Group (ECOG) performance status ≤ 2
  6. Ability to provide written informed consent

Exclusion Criteria:

  1. Presence of distant metastasis
  2. Prior biliary stent placement for biliary obstruction
  3. Requirement for duodenal stent placement due to gastric outlet obstruction
  4. Estimated life expectancy < 3 months
  5. Inability to undergo ERCP
  6. Any condition that, in the opinion of the investigator, would make participation unsafe or interfere with study outcomes

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: M-FCSEMS group
Participants in this arm will undergo endoscopic retrograde cholangiopancreatography (ERCP) with placement of a modified 8-mm fully covered self-expandable metal stent (FCSEMS) for preoperative biliary drainage.
A modified non-flared 8-mm fully covered self-expandable metal stent designed for preoperative biliary drainage. The stent features a dumbbell-shaped structure with a narrower central portion to reduce migration, a fully covered membrane to prevent tissue ingrowth, and a retrieval lasso to facilitate removal. It is deployed via ERCP across the malignant biliary stricture.
Otros nombres:
  • M-FCSEMS
Comparador activo: PS group
Participants in this arm will undergo endoscopic retrograde cholangiopancreatography (ERCP) with placement of a plastic stent (PS) for preoperative biliary drainage.
A conventional 8.5-Fr plastic biliary stent used for preoperative biliary drainage. The stent is placed via ERCP across the malignant biliary stricture and represents the standard treatment option, although it is associated with shorter patency and a higher risk of occlusion compared to metal stents.
Otros nombres:
  • PD

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Stent-Related Non-Event Rate at Surgery
Periodo de tiempo: From stent placement to the time of surgery
The proportion of patients who do not require reintervention due to stent-related complications from stent placement until the time of surgery.
From stent placement to the time of surgery

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Recurrent Biliary Obstruction Rate
Periodo de tiempo: From stent placement to RBO, assessed up to 24 months
The proportion of patients who develop recurrent biliary obstruction requiring reintervention
From stent placement to RBO, assessed up to 24 months
Time to Recurrent Biliary Obstruction
Periodo de tiempo: From stent placement to first RBO, assessed up to 24 months
Time from stent placement to the occurrence of recurrent biliary obstruction
From stent placement to first RBO, assessed up to 24 months
Stent-Related Adverse Events
Periodo de tiempo: Within 30 days after procedure
Incidence of adverse events related to stent placement, including pancreatitis, cholangitis, cholecystitis, bleeding, perforation, or stent migration
Within 30 days after procedure
Technical Success Rate
Periodo de tiempo: During the index procedure
Successful placement of the stent across the target biliary stricture in the intended position
During the index procedure
Surgery Completion Rate
Periodo de tiempo: Up to surgery
The proportion of patients who undergo planned surgical resection after biliary drainage
Up to surgery
Overall Survival
Periodo de tiempo: From procedure to death from any cause, assessed up to 24 months
Time from stent placement to death from any cause
From procedure to death from any cause, assessed up to 24 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de mayo de 2026

Finalización primaria (Estimado)

31 de diciembre de 2028

Finalización del estudio (Estimado)

31 de diciembre de 2029

Fechas de registro del estudio

Enviado por primera vez

6 de mayo de 2026

Primero enviado que cumplió con los criterios de control de calidad

18 de mayo de 2026

Publicado por primera vez (Actual)

26 de mayo de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

26 de mayo de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

18 de mayo de 2026

Última verificación

1 de mayo de 2026

Más información

Términos relacionados con este estudio

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Descripción del plan IPD

A plan for sharing individual participant data has not been finalized. Any future data sharing will be considered in accordance with institutional policies, ethical standards, and regulatory requirements.

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir