- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07606430
Comparison of a Short Modified Metal Stent Versus Plastic Stent as a Bridge to Surgery in Pancreatic Cancer With Malignant Biliary Obstruction (BRIDGE-8)
Multicenter Randomized Trial of a Short Modified 8-mm-diameter Fully Covered Metal Stent Versus Plastic Stent as a Bridge to Surgery in Pancreatic Cancer With Malignant Biliary Obstruction
This study is a multicenter, randomized clinical trial designed to compare the effectiveness and safety of a modified 8-mm fully covered self-expandable metal stent (FCSEMS) with a conventional plastic stent for preoperative biliary drainage in patients with pancreatic cancer and malignant biliary obstruction.
In patients who require biliary drainage before surgery, stent placement is commonly performed using endoscopic retrograde cholangiopancreatography (ERCP). However, the optimal stent type remains uncertain.
Participants will be randomly assigned to receive either the modified FCSEMS or a plastic stent. The primary objective is to evaluate the rate of stent-related complications requiring reintervention before surgery. Secondary outcomes include stent patency, adverse events, and surgical outcomes.
The results of this study are expected to help determine the most appropriate stent strategy for patients undergoing surgery for pancreatic cancer.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Pancreatic cancer is a highly aggressive malignancy with a poor prognosis, and many patients present with malignant biliary obstruction at the time of diagnosis. Preoperative biliary drainage is frequently required in patients undergoing neoadjuvant chemotherapy or delayed surgery to relieve jaundice and prevent complications such as cholangitis.
Endoscopic retrograde cholangiopancreatography (ERCP) with stent placement is the standard approach for biliary drainage. Plastic stents (PS) are widely used due to their low cost and ease of removal; however, they are associated with a relatively short patency and frequent occlusion, often necessitating repeated interventions. Fully covered self-expandable metal stents (FCSEMS) have demonstrated longer patency, but concerns remain regarding adverse events and potential impact on subsequent surgical procedures.
A modified non-flared 8-mm diameter FCSEMS has been developed to reduce complications while maintaining adequate patency. Its design includes a dumbbell-shaped structure with a narrower central portion to prevent migration, a fully covered membrane to reduce tissue ingrowth, and a retrieval lasso to facilitate removal. This design may offer advantages over both conventional FCSEMS and plastic stents in the preoperative setting.
This study is a prospective, multicenter, open-label, randomized controlled trial designed to compare a modified 8-mm FCSEMS with a plastic stent for preoperative biliary drainage in patients with pancreatic cancer and malignant biliary obstruction. Eligible patients will be randomly assigned in a 1:1 ratio to receive either the modified FCSEMS or a plastic stent.
The primary endpoint is the stent-related non-event rate at the time of surgery, defined as the proportion of patients who do not require reintervention due to stent-related complications before surgery. Secondary endpoints include the incidence of recurrent biliary obstruction, time to recurrent biliary obstruction, stent-related adverse events, technical success, surgical outcomes, and overall survival.
All procedures will be performed using standard ERCP techniques by experienced endoscopists. Patients will be followed until surgery and throughout the postoperative period to assess clinical outcomes.
The findings of this study are expected to provide evidence to guide optimal stent selection for preoperative biliary drainage in patients with pancreatic cancer, particularly in the context of neoadjuvant treatment strategies.
Tipo de estudio
Inscripción (Estimado)
Fase
- No aplica
Contactos y Ubicaciones
Estudio Contacto
- Nombre: Il Sang Shin, Assistant Professor
- Número de teléfono: +82-10-4658-8794
- Correo electrónico: ilsang.shin@schmc.ac.kr
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Descripción
Inclusion Criteria:
- Age ≥ 18 years
- Patients with resectable, borderline resectable, or locally advanced pancreatic cancer with distal malignant biliary obstruction requiring endoscopic biliary drainage
- Biliary stricture located ≥ 2 cm below the hepatic hilum
- Serum bilirubin ≥ 3 mg/dL
- Eastern Cooperative Oncology Group (ECOG) performance status ≤ 2
- Ability to provide written informed consent
Exclusion Criteria:
- Presence of distant metastasis
- Prior biliary stent placement for biliary obstruction
- Requirement for duodenal stent placement due to gastric outlet obstruction
- Estimated life expectancy < 3 months
- Inability to undergo ERCP
- Any condition that, in the opinion of the investigator, would make participation unsafe or interfere with study outcomes
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: M-FCSEMS group
Participants in this arm will undergo endoscopic retrograde cholangiopancreatography (ERCP) with placement of a modified 8-mm fully covered self-expandable metal stent (FCSEMS) for preoperative biliary drainage.
|
A modified non-flared 8-mm fully covered self-expandable metal stent designed for preoperative biliary drainage.
The stent features a dumbbell-shaped structure with a narrower central portion to reduce migration, a fully covered membrane to prevent tissue ingrowth, and a retrieval lasso to facilitate removal.
It is deployed via ERCP across the malignant biliary stricture.
Otros nombres:
|
|
Comparador activo: PS group
Participants in this arm will undergo endoscopic retrograde cholangiopancreatography (ERCP) with placement of a plastic stent (PS) for preoperative biliary drainage.
|
A conventional 8.5-Fr plastic biliary stent used for preoperative biliary drainage.
The stent is placed via ERCP across the malignant biliary stricture and represents the standard treatment option, although it is associated with shorter patency and a higher risk of occlusion compared to metal stents.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Stent-Related Non-Event Rate at Surgery
Periodo de tiempo: From stent placement to the time of surgery
|
The proportion of patients who do not require reintervention due to stent-related complications from stent placement until the time of surgery.
|
From stent placement to the time of surgery
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Recurrent Biliary Obstruction Rate
Periodo de tiempo: From stent placement to RBO, assessed up to 24 months
|
The proportion of patients who develop recurrent biliary obstruction requiring reintervention
|
From stent placement to RBO, assessed up to 24 months
|
|
Time to Recurrent Biliary Obstruction
Periodo de tiempo: From stent placement to first RBO, assessed up to 24 months
|
Time from stent placement to the occurrence of recurrent biliary obstruction
|
From stent placement to first RBO, assessed up to 24 months
|
|
Stent-Related Adverse Events
Periodo de tiempo: Within 30 days after procedure
|
Incidence of adverse events related to stent placement, including pancreatitis, cholangitis, cholecystitis, bleeding, perforation, or stent migration
|
Within 30 days after procedure
|
|
Technical Success Rate
Periodo de tiempo: During the index procedure
|
Successful placement of the stent across the target biliary stricture in the intended position
|
During the index procedure
|
|
Surgery Completion Rate
Periodo de tiempo: Up to surgery
|
The proportion of patients who undergo planned surgical resection after biliary drainage
|
Up to surgery
|
|
Overall Survival
Periodo de tiempo: From procedure to death from any cause, assessed up to 24 months
|
Time from stent placement to death from any cause
|
From procedure to death from any cause, assessed up to 24 months
|
Colaboradores e Investigadores
Patrocinador
Publicaciones y enlaces útiles
Publicaciones Generales
- Povoski SP, Karpeh MS Jr, Conlon KC, Blumgart LH, Brennan MF. Association of preoperative biliary drainage with postoperative outcome following pancreaticoduodenectomy. Ann Surg. 1999 Aug;230(2):131-42. doi: 10.1097/00000658-199908000-00001.
- Shin IS, Moon JH, Lee YN, Chung JC, Jeong J, Choi SY, Lee TH, Yang JK, Cha SW, Cho YD, Park SH. Modified non-flared fully covered self-expandable metal stent for preoperative biliary drainage in pancreatic cancer. J Gastroenterol Hepatol. 2022 Jan;37(1):225-232. doi: 10.1111/jgh.15733. Epub 2021 Nov 19.
- Lee HW, Moon JH, Lee YN, Chung JC, Lee TH, Choi MH, Cha SW, Cho YD, Park SH. Modified non-flared fully covered self-expandable metal stent versus plastic stent for preoperative biliary drainage in patients with resectable malignant biliary obstruction. J Gastroenterol Hepatol. 2019 Sep;34(9):1590-1596. doi: 10.1111/jgh.14600. Epub 2019 Feb 27.
- Neoptolemos JP, Kleeff J, Michl P, Costello E, Greenhalf W, Palmer DH. Therapeutic developments in pancreatic cancer: current and future perspectives. Nat Rev Gastroenterol Hepatol. 2018 Jun;15(6):333-348. doi: 10.1038/s41575-018-0005-x.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Estimado)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 2025-08-001
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Descripción del plan IPD
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .