Diese Seite wurde automatisch übersetzt und die Genauigkeit der Übersetzung wird nicht garantiert. Bitte wende dich an die englische Version für einen Quelltext.

Comparison of a Short Modified Metal Stent Versus Plastic Stent as a Bridge to Surgery in Pancreatic Cancer With Malignant Biliary Obstruction (BRIDGE-8)

18. Mai 2026 aktualisiert von: Il Sang Shin, Soonchunhyang University Hospital

Multicenter Randomized Trial of a Short Modified 8-mm-diameter Fully Covered Metal Stent Versus Plastic Stent as a Bridge to Surgery in Pancreatic Cancer With Malignant Biliary Obstruction

This study is a multicenter, randomized clinical trial designed to compare the effectiveness and safety of a modified 8-mm fully covered self-expandable metal stent (FCSEMS) with a conventional plastic stent for preoperative biliary drainage in patients with pancreatic cancer and malignant biliary obstruction.

In patients who require biliary drainage before surgery, stent placement is commonly performed using endoscopic retrograde cholangiopancreatography (ERCP). However, the optimal stent type remains uncertain.

Participants will be randomly assigned to receive either the modified FCSEMS or a plastic stent. The primary objective is to evaluate the rate of stent-related complications requiring reintervention before surgery. Secondary outcomes include stent patency, adverse events, and surgical outcomes.

The results of this study are expected to help determine the most appropriate stent strategy for patients undergoing surgery for pancreatic cancer.

Studienübersicht

Detaillierte Beschreibung

Pancreatic cancer is a highly aggressive malignancy with a poor prognosis, and many patients present with malignant biliary obstruction at the time of diagnosis. Preoperative biliary drainage is frequently required in patients undergoing neoadjuvant chemotherapy or delayed surgery to relieve jaundice and prevent complications such as cholangitis.

Endoscopic retrograde cholangiopancreatography (ERCP) with stent placement is the standard approach for biliary drainage. Plastic stents (PS) are widely used due to their low cost and ease of removal; however, they are associated with a relatively short patency and frequent occlusion, often necessitating repeated interventions. Fully covered self-expandable metal stents (FCSEMS) have demonstrated longer patency, but concerns remain regarding adverse events and potential impact on subsequent surgical procedures.

A modified non-flared 8-mm diameter FCSEMS has been developed to reduce complications while maintaining adequate patency. Its design includes a dumbbell-shaped structure with a narrower central portion to prevent migration, a fully covered membrane to reduce tissue ingrowth, and a retrieval lasso to facilitate removal. This design may offer advantages over both conventional FCSEMS and plastic stents in the preoperative setting.

This study is a prospective, multicenter, open-label, randomized controlled trial designed to compare a modified 8-mm FCSEMS with a plastic stent for preoperative biliary drainage in patients with pancreatic cancer and malignant biliary obstruction. Eligible patients will be randomly assigned in a 1:1 ratio to receive either the modified FCSEMS or a plastic stent.

The primary endpoint is the stent-related non-event rate at the time of surgery, defined as the proportion of patients who do not require reintervention due to stent-related complications before surgery. Secondary endpoints include the incidence of recurrent biliary obstruction, time to recurrent biliary obstruction, stent-related adverse events, technical success, surgical outcomes, and overall survival.

All procedures will be performed using standard ERCP techniques by experienced endoscopists. Patients will be followed until surgery and throughout the postoperative period to assess clinical outcomes.

The findings of this study are expected to provide evidence to guide optimal stent selection for preoperative biliary drainage in patients with pancreatic cancer, particularly in the context of neoadjuvant treatment strategies.

Studientyp

Interventionell

Einschreibung (Geschätzt)

116

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienkontakt

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

  • Erwachsene
  • Älterer Erwachsener

Akzeptiert gesunde Freiwillige

Nein

Beschreibung

Inclusion Criteria:

  1. Age ≥ 18 years
  2. Patients with resectable, borderline resectable, or locally advanced pancreatic cancer with distal malignant biliary obstruction requiring endoscopic biliary drainage
  3. Biliary stricture located ≥ 2 cm below the hepatic hilum
  4. Serum bilirubin ≥ 3 mg/dL
  5. Eastern Cooperative Oncology Group (ECOG) performance status ≤ 2
  6. Ability to provide written informed consent

Exclusion Criteria:

  1. Presence of distant metastasis
  2. Prior biliary stent placement for biliary obstruction
  3. Requirement for duodenal stent placement due to gastric outlet obstruction
  4. Estimated life expectancy < 3 months
  5. Inability to undergo ERCP
  6. Any condition that, in the opinion of the investigator, would make participation unsafe or interfere with study outcomes

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Behandlung
  • Zuteilung: Zufällig
  • Interventionsmodell: Parallele Zuordnung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: M-FCSEMS group
Participants in this arm will undergo endoscopic retrograde cholangiopancreatography (ERCP) with placement of a modified 8-mm fully covered self-expandable metal stent (FCSEMS) for preoperative biliary drainage.
A modified non-flared 8-mm fully covered self-expandable metal stent designed for preoperative biliary drainage. The stent features a dumbbell-shaped structure with a narrower central portion to reduce migration, a fully covered membrane to prevent tissue ingrowth, and a retrieval lasso to facilitate removal. It is deployed via ERCP across the malignant biliary stricture.
Andere Namen:
  • M-FCSEMS
Aktiver Komparator: PS group
Participants in this arm will undergo endoscopic retrograde cholangiopancreatography (ERCP) with placement of a plastic stent (PS) for preoperative biliary drainage.
A conventional 8.5-Fr plastic biliary stent used for preoperative biliary drainage. The stent is placed via ERCP across the malignant biliary stricture and represents the standard treatment option, although it is associated with shorter patency and a higher risk of occlusion compared to metal stents.
Andere Namen:
  • PS

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Stent-Related Non-Event Rate at Surgery
Zeitfenster: From stent placement to the time of surgery
The proportion of patients who do not require reintervention due to stent-related complications from stent placement until the time of surgery.
From stent placement to the time of surgery

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Recurrent Biliary Obstruction Rate
Zeitfenster: From stent placement to RBO, assessed up to 24 months
The proportion of patients who develop recurrent biliary obstruction requiring reintervention
From stent placement to RBO, assessed up to 24 months
Time to Recurrent Biliary Obstruction
Zeitfenster: From stent placement to first RBO, assessed up to 24 months
Time from stent placement to the occurrence of recurrent biliary obstruction
From stent placement to first RBO, assessed up to 24 months
Stent-Related Adverse Events
Zeitfenster: Within 30 days after procedure
Incidence of adverse events related to stent placement, including pancreatitis, cholangitis, cholecystitis, bleeding, perforation, or stent migration
Within 30 days after procedure
Technical Success Rate
Zeitfenster: During the index procedure
Successful placement of the stent across the target biliary stricture in the intended position
During the index procedure
Surgery Completion Rate
Zeitfenster: Up to surgery
The proportion of patients who undergo planned surgical resection after biliary drainage
Up to surgery
Overall Survival
Zeitfenster: From procedure to death from any cause, assessed up to 24 months
Time from stent placement to death from any cause
From procedure to death from any cause, assessed up to 24 months

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Publikationen und hilfreiche Links

Die Bereitstellung dieser Publikationen erfolgt freiwillig durch die für die Eingabe von Informationen über die Studie verantwortliche Person. Diese können sich auf alles beziehen, was mit dem Studium zu tun hat.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Geschätzt)

1. Mai 2026

Primärer Abschluss (Geschätzt)

31. Dezember 2028

Studienabschluss (Geschätzt)

31. Dezember 2029

Studienanmeldedaten

Zuerst eingereicht

6. Mai 2026

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

18. Mai 2026

Zuerst gepostet (Tatsächlich)

26. Mai 2026

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

26. Mai 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

18. Mai 2026

Zuletzt verifiziert

1. Mai 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

UNENTSCHIEDEN

Beschreibung des IPD-Plans

A plan for sharing individual participant data has not been finalized. Any future data sharing will be considered in accordance with institutional policies, ethical standards, and regulatory requirements.

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Klinische Studien zur Bauchspeicheldrüsenkrebs

Klinische Studien zur Modified 8-mm Fully Covered Self-Expandable Metal Stent

Abonnieren