A PROSPECTIVE, RANDOMIZED, TWO-ARM, CONTROLLED, SINGLE-BLIND, MULTI-CENTER STUDY TO EVALUATE THE SAFETY AND EFFICACY OF ARTIFIX® DURAL REPAIR SEALANT GRAFT IN CRANIAL AND SPINE SURGERY (NEOFIX STUDY) (NEOFIX)

10 de agosto de 2026 actualizado por: Nurami Medical Ltd
The purpose of the NEOFIX study is to evaluate the safety and efficacy of ArtiFix® dural sealant graft in comparison to usual treatment for Dural repair (membrane that covers the brain and spinal cord) following cranial and spine surgeries. The investigated device will be implanted during the neurosurgical procedure and participants will be evaluated at 16, 36 and 120 days after the procedure.

Descripción general del estudio

Tipo de estudio

Intervencionista

Inscripción (Estimado)

228

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Copia de seguridad de contactos de estudio

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Descripción

Inclusion Criteria:

Pre-operative inclusion criteria:

  1. Male or female aged ≥18 and <80 years.
  2. Subject is scheduled for an elective cranial or spine surgery with a potential[EG4.1] dural defect that can be repaired by ArtiFix® graft or Control. The maximal estimated dural defect is 25cm2 with an intact dural margins of at least 5 mm surrounding the defect.
  3. Subject has undergone MRI or CT that includes the planned implantation area in the past 6 months before screening.
  4. Surgical wound is expected to be Class I/clean.
  5. Subject understands the study requirements and procedures and provides written Informed Consent before any study-specific tests or procedures. Subject is able and willing to adhere to the follow-up visits and tests.

    Intra-operative Inclusion criteria:

  6. CSF leakage is observed from the dural defect, either spontaneously or during a Valsalva maneuver.
  7. The ArtiFix® or control can cover a maximum dural defect size of 25 cm². The dural defect must be suitable for coverage with at least 5 mm of intact dural surface surrounding the defect.

Exclusion Criteria:

Pre-operative exclusion criteria:

  1. Dural gap is ≤ 2 mm in cranial procedures. In spine procedures the minimal dural gap is not limited.
  2. Subject is unable to undergo MRI after the surgery (only closed bore MRI is allowed; open bore is not allowed).
  3. Subject is an acute cranial or spine traumatic surgical case or diagnosed as nontraumatic hemorrhagic CVA that requires urgent craniectomy.
  4. Subject is operated to repair Chiari malformation, or with a transsphenoidal approach, or that their surgery involves penetration of air cells, of any kind.
  5. Subject had a previous surgery in the same anatomical site.
  6. Subject has known hydrocephalus or other CSF obstruction disorder or has been treated for hydrocephalus with shunt insertion in the past 10 years.
  7. Subject is currently or was diagnosed in the past 5 years with malignancy, excluding basal cell carcinoma or low-grade tumors (i.e., meningioma, ependymoma, schwannoma, hemangioblastoma and other tumors defined as low grade, are eligible to participate).
  8. Intra-operative Valsalva maneuver poses a risk to the subject, as determined by the surgeon or the anesthesiologist.
  9. Subject has a local or systemic infection (e.g. urinary tract infection, active pneumonia) or evidence of any surgical site infection, fever > 38.3℃, or positive blood culture.
  10. Subject has a compromised immune system or an active autoimmune disease, or is on immunosuppressant agents, long term anti-inflammatory biological agents or is on chronic systemic steroid treatment (excluding peri-operative steroid treatment).
  11. Subjected is diagnosed with sepsis, or systemic collagen disease.
  12. Subject at high risk of delayed or failed wound healing due to past treatments or conditions.
  13. Subject has been diagnosed with kidney failure regardless of grade, as evident by serum creatinine levels >1.3 mg/dL.
  14. Subject was diagnosed with liver disease evident by any of the following test results: ALT > 55 U/L, AST > 48 U/L, ALP > 129 U/L, GGT > 61 U/L, Total bilirubin > 1.3 mg/dL, Albumin < 3.5 g/Dl, INR > 1.2, or PT > 15 sec.
  15. Subject has been diagnosed with an uncontrolled diabetes mellitus, as evident by HbA1c > 7%, or suffered recurrent episodes of hypoglycemia in the past 2 months.
  16. Subject had chemotherapy and/or radiotherapy in the past 8 weeks before surgery or is planned to have chemotherapy or radiotherapy less than 8 weeks after surgery.
  17. Subject requires an external ventricular or lumbar CSF drain that must be left in place after surgery.
  18. Subject has congenital or acquired coagulopathy.
  19. The subject was classified as exhibiting drug abuse.
  20. Subject has any condition that, in the Principal Investigator's judgment, may compromise the subject's safety or preclude compliance with the study investigation plan and/or device instructions.
  21. Subject is participating in another clinical trial that tests any other drug or device.
  22. Subject is pregnant or breast-feeding at screening or intends to become pregnant during the study period.
  23. Subject has known history of sensitivity or allergy to any component of the ArtiFix®.

    Intra-operative Exclusion criteria:

  24. Dural gap is ≤ 2 mm in cranial procedures. In spine procedures the minimal dural gap is not limited.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación paralela
  • Enmascaramiento: Doble

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Comparador activo: Tratamiento estándar de atención
Standard-of-care for dural repair in spine or cranial procedures (only FDA cleared graft devices and approved sealants will be used)
Experimental: ArtiFix the investigational device
ArtiFix® is a sterile, synthetic, single use, adhesive, resorbable sealant graft intended to seal and repair dural defects following cranial or spinal surgeries.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Periodo de tiempo
The absence of device-related CSF leakage or re-operation of the implantation site within 120 days after implantation.
Periodo de tiempo: at 120 days after ArtiFix® or control implantation
at 120 days after ArtiFix® or control implantation
The absence of device-related CSF leakage or re-operation of the implantation site within 120 days after implantation.
Periodo de tiempo: at 120 days after ArtiFix® implantation.
at 120 days after ArtiFix® implantation.

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Director de estudio: Joseph Milbaum, MD, Nurami Medical

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de enero de 2027

Finalización primaria (Estimado)

1 de enero de 2029

Finalización del estudio (Estimado)

1 de enero de 2029

Fechas de registro del estudio

Enviado por primera vez

10 de agosto de 2026

Primero enviado que cumplió con los criterios de control de calidad

10 de agosto de 2026

Publicado por primera vez (Actual)

14 de agosto de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

14 de agosto de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

10 de agosto de 2026

Última verificación

1 de agosto de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • PLN-0000265

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

producto fabricado y exportado desde los EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .