Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Pancreatic Endoscopic Ultrasound-guided RadioFrequency for Inoperable Carcinoma Treatment (PERFECT)

24 de septiembre de 2026 actualizado por: Bojan Kovacevic

Pancreatic Endoscopic Ultrasound-guided RadioFrequency for Inoperable Carcinoma Treatment (PERFECT Study)

The purpose of this study is to evaluate whether endoscopic ultrasound-guided radiofrequency ablation (EUS-RFA) affects survival in patients with inoperable pancreatic carcinoma. By using a prospective single-arm design with historical controls, this study aims to generate clinically relevant data while minimizing the number of patients exposed to experimental treatment. The findings may support future integration of EUS-RFA into standard care for this high-need patient population.

Descripción general del estudio

Tipo de estudio

Intervencionista

Inscripción (Estimado)

56

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Estudio Contacto

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

18 años y mayores (Adulto, Adulto Mayor)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  • Adult habile patients with a signed informed consent
  • Histologically confirmed pancreatic carcinoma ≤5 cm in largest diameter
  • ECOG performance status 0-2
  • Patients not eligible for curative-intended surgical treatment due to:

Advanced (unresectable) disease, or Unsuitability for surgery due to comorbidities or poor performance status, or Patient preference to decline surgery

Exclusion Criteria:

  • Metastatic disease
  • Uncorrected coagulopathy (INR ≥1.5 or thrombocyte count < 50 mia/L)
  • Altered anatomy or interposition of major vessels precluding safe EUS-RFA
  • Active untreated infection or pancreatitis
  • Life expectancy <3 months
  • Prior local ablative treatment interfering with outcome

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: EUS-RFA plus standard oncological treatment

Participants receive endoscopic ultrasound-guided radiofrequency ablation (EUS-RFA) using a 19G RFA needle (EUSRA, STARMed, Gyeonggi-do, South Korea) connected to an RF generator, as a supplement to standard palliative oncological treatment. EUS-RFA is performed under deep sedation or general anesthesia and may be repeated at approximately 4-week intervals contingent on patient condition. All participants continue standard oncological follow-up, including systemic therapy and regular cross-sectional imaging, in parallel with the study intervention.

A 19G RFA needle (EUSRA, STARMed, Gyeonggi-do, South Korea) is introduced through the working channel of an echoendoscope and advanced into the pancreatic tumor under real-time ultrasound guidance.

The needle is connected to a dedicated RF generator delivering a current of 400-500 kHz, which induces coagulative necrosis in the targeted tissue. Treatment is continued until complete ablation is confirmed ultrasonographically, or until an impedance value of 800 Ω is reached, at which point the generator automatically terminates power output to limit further tissue damage. A cooling pump circulates chilled saline through the needle to reduce charring at the ablation site. The procedure is performed transgastrically or transduodenally under deep sedation or general anesthesia, and may involve one or more ablation cycles per session. Treatment may be repeated at approximately 4-week intervals, depending on radiological response and patient tolerance.

Otros nombres:
  • EUS-RFA

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Overall survival
Periodo de tiempo: From index date until death from any cause, assessed up to 4 years

Time from index date (first day of systemic oncological therapy or first visit at the Department of Oncology (for patients who do not receive systemic therapy)) to death from any cause. Participants alive at the time of last follow-up will be censored at that date.

From index date until death from any cause, assessed up to 4 years

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Progression- and metastatic-free survival
Periodo de tiempo: From index date until progression, metastasis, or last follow-up, assessed up to approximately 4 years

Time from index date to radiological progression of the primary tumor or development of distant metastases, assessed according to RECIST 1.1 on cross-sectional imaging.

From index date until progression, metastasis, or last follow-up, assessed up to approximately 4 years
Local tumor control at 6 and 12 months
Periodo de tiempo: At 6 and 12 months after index date

Proportion of participants with local tumor control (absence of local progression) on cross-sectional imaging at 6 and 12 months, assessed according to RECIST 1.1.

At 6 and 12 months after index date
Procedure-related adverse events
Periodo de tiempo: At 30 days after each EUS-RFA procedure

Adverse events occurring within 30 days of each EUS-RFA treatment, graded according to the AGREE classification.

At 30 days after each EUS-RFA procedure
Time to biliary/duodenal intervention
Periodo de tiempo: From index date until intervention or last follow-up, assessed up to approximately 4 years

Time from index date to first biliary or duodenal intervention (e.g., stenting)

From index date until intervention or last follow-up, assessed up to approximately 4 years
Pain score change compared to baseline
Periodo de tiempo: Baseline and at 6, 12 and 18 months after inclusion

Change from baseline in pain severity, measured using a Numeric Rating Scale (NRS, 0-10)

Baseline and at 6, 12 and 18 months after inclusion
Opioid consumption change compared to baseline
Periodo de tiempo: Baseline and at 6, 12 and 18 months after inclusion

Change in opioid consumption, converted to total daily oral morphine milligram equivalent (MME).

Baseline and at 6, 12 and 18 months after inclusion
Quality of Life change compared to baseline (EORTC QLQ-C30)
Periodo de tiempo: Baseline and at 6, 12 and 18 months

Change from baseline in the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaire Core 30 (EORTC QLQ-C30), Global Health Status/Quality of Life scale, ranging from 0 (worst) to 100 (best), with higher scores indicating better quality of life.

Baseline and at 6, 12 and 18 months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Investigadores

  • Investigador principal: Bojan Kovacevic, MD, PhD, Herlev Hospital

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Estimado)

1 de octubre de 2026

Finalización primaria (Estimado)

1 de diciembre de 2030

Finalización del estudio (Estimado)

1 de diciembre de 2030

Fechas de registro del estudio

Enviado por primera vez

17 de septiembre de 2026

Primero enviado que cumplió con los criterios de control de calidad

24 de septiembre de 2026

Publicado por primera vez (Actual)

30 de septiembre de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

30 de septiembre de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

24 de septiembre de 2026

Última verificación

1 de julio de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • 16-0302-148

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

INDECISO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

producto fabricado y exportado desde los EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir