- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT03842059
Computer-aided Detection for Colonoscopy
Computer-aided Detection With Deep Learning for Colorectal Adenoma During Colonoscopic Examination
Tutkimuksen yleiskatsaus
Tila
Interventio / Hoito
Yksityiskohtainen kuvaus
Colonoscopy is a primary screening and follow-up tool to detect colorectal cancer, a third leading cause of cancer death in Taiwan. Most colorectal cancers (CRCs) arise from preexisting adenomas, and the adenoma-carcinoma sequence offers an opportunity for the screening and prevention of CRCs. The removal of adenomatous polyps can lower the incidence of CRCs and result in reduced motality from CRCs. The adenoma detection rate, the proportion of screening colonoscopies performed by a endoscopist that detect at least one colorectal adenoma or adenocarcinoma, has been recommended as a quality indicator. The adenoma detection rate was inversely associated with the risks of interval colorectal cancer, advanced-stage interval cancer, and fatal interval cancer. However, adenoma detection rates vary widely among endoscopists in both academic and community settings. Polyp miss rates as high as 20% have been reported for high definition resolution colonoscopy. An improvement in adenoma detection rate at screening colonoscopy, translates into reduced risks of interval colorectal cancer and colorectal cancer death. Computer-aided detection of polyps might assist endoscopists to reduce the miss rate and enhance screening performance during colonoscopy. Computer-aided diagnosis and computer-aided detection are computerized systems that learn and inference in medical fields. Computer-aided diagnosis has been developed in colon polyp classification.
Computer-assisted image analysis has the potential to further aid adenoma detection but has remained underdeveloped. A notable benefit of such a system is that no alteration of the colonoscope or procedure is necessary. Machine learning with a deep neural network has been successfully applied to many areas of science and technology, such as object recognition and detection of computer vision, speech recognition, natural language processing. We developed an artificial intelligent computer system (PX-1) with a deep neural network to analyze real-time video signals from the endoscopy station. This randomised controlled trial compared ADR between computer-assisted colonoscopy and standard colonoscopy.
Opintotyyppi
Ilmoittautuminen (Odotettu)
Vaihe
- Ei sovellettavissa
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
Patients aged ≥20 years, scheduled for colonoscopy for one of the following indications for colonoscopy, were invited to participate in this study: polyp surveillance, changed bowel habits and/or bloody stools, bowel complaints, a positive family history for CRC, a positive FOBT, abdominal pain, diarrhoea, post-polypectomy surveillance.
Exclusion Criteria:
We excluded patients from this study if: (1) they had known colonic neoplasia or inflammatory or other significant colonic disease, such as patients specifically presenting for polypectomy; (2) there was open bleeding or they were receiving an emergency colonoscopy; (3) they had previously previous colonic resection; (4) they were in poor general condition (more than American Society of Anesthesiologists grade III); (5) they were receiving anticoagulant medication; (6) they had severe comorbidity, including end-stage cardiovascular, pulmonary, liver or renal disease); (7) they were not able or refused to give informed written consent; (8) following enrolment and randomisation to one of the arms, those subjects who had inadequate colon preparation or in whom the caecum could not be reached were also excluded.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Seulonta
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Kaksinkertainen
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Kokeellinen: Computer-aided detection
|
We developed an artificial intelligent computer system with a deep neural network (PX-1) to analyze real-time video signals from the endoscopy station
|
|
Placebo Comparator: Standard colonoscopy
|
Normaali kolonoskopia
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Adenoma detection rate
Aikaikkuna: During colonoscopic examination procedure
|
Adenoma detection rate
|
During colonoscopic examination procedure
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
adenomas detected per subject
Aikaikkuna: During colonoscopic examination procedure
|
adenomas detected per subject
|
During colonoscopic examination procedure
|
Yhteistyökumppanit ja tutkijat
Sponsori
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Odotettu)
Ensisijainen valmistuminen (Odotettu)
Opintojen valmistuminen (Odotettu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muut tutkimustunnusnumerot
- 107-2314-B-016 -011-MY2
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .