- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT07703943
Ultrasonographic Effects of Fascia Correction Kinesiotaping
Investigation of the Physiological Effects of Fascia Correction Kinesiotaping in Healthy Adults: An Ultrasonographic Study
Single-center, within-subject repeated-measures study The aim of the present study was to investigate the acute effects of kinesiotaping applied using the fascia correction technique with different tension levels on fascial layers and associated musculature in healthy individuals.
Outcome measurements. The primary outcome was the ultrasonographically measured thickness of the fascial layers, while secondary outcomes included the thickness of the superficial and deep flexor muscle layers and the subcutaneous tissue.
Tutkimuksen yleiskatsaus
Yksityiskohtainen kuvaus
The fascial system plays an important role in force transmission, movement coordination, and interaction between musculoskeletal structures. Kinesiotaping is a commonly used therapeutic approach in rehabilitation, and the fascia correction technique has been proposed to influence fascial mobility and mechanical properties. However, the acute effects of different kinesiotape tension levels applied with the fascia correction technique on fascial and underlying musculoskeletal structures remain unclear.This single-center, within-subject repeated-measures study aims to investigate the immediate effects of kinesiotaping applied using the fascia correction technique with different tension levels on fascial layers and associated soft tissues in healthy individuals.
Healthy volunteers aged 18 years or older will be included. Participants will undergo kinesiotape application with different tension levels according to the study protocol. Ultrasonographic assessments will be performed to evaluate changes in fascial layer thickness as the primary outcome. Secondary outcomes will include ultrasonographic measurements of superficial and deep flexor muscle thickness and subcutaneous tissue thickness.
The study is designed to provide objective ultrasonographic measurements of acute tissue responses following kinesiotaping application and to improve understanding of the potential mechanical effects of the fascia correction technique on fascial and musculoskeletal structures.
Opintotyyppi
Ilmoittautuminen (Todellinen)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
-
Istanbul, Turkki (Türkiye)
- Haydarpasa Numune Training and Research Hospital
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
Hyväksyy terveitä vapaaehtoisia
Kuvaus
Inclusion Criteria:
A total of 80 healthy volunteers aged 18 years or older were included in the study. Participants had no current or previous serious musculoskeletal injury, pain, or neurological disorder affecting the upper extremity within the past six months
Exclusion Criteria:
Individuals were excluded if they were pregnant; regularly participated in high-level athletic training or competitive sports, had a history of skin allergy to adhesive materials; or had previous kinesiotaping application within the last month.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Seulonta
- Jako: Ei käytössä
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Kokeellinen: Healthy Volunteers
Participants received kinesiotaping using the fascia correction technique at different tension levels according to the study protocol.
Each participant underwent all intervention conditions, and ultrasonographic measurements were performed before and after each application.
|
Fascia correction technique kinesiotaping
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
The superficial antebrachial fascia thickness
Aikaikkuna: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
ultrasonographic measurements were obtained from the dominant forearm at the mid-forearm level.
the hyperechoic linear structure separating the subcutaneous tissue from the superficial flexor muscles was defined as superficial antebrachial fascia thickness
|
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
|
The deep antebrachial fascia thickness
Aikaikkuna: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Ultrasonographic measurements were obtained from the dominant forearm at the mid-forearm level.
the hyperechoic linear structure separating the superficial and deep flxor muscles was defined as superficial antebrachial fascia thickness
|
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
the subcutaneous tissue thickness
Aikaikkuna: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Subcutaneous tissue thickness measured by B-mode ultrasonography (millimeters)
|
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
|
Forearm Superficial Flexor Muscle Thickness
Aikaikkuna: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Forearm superficial flexor muscle thickness measured by B-mode ultrasonography (millimeters)
|
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
|
Forearm deep flexor muscle thickness measured by B-mode ultrasonography (millimeters)
Aikaikkuna: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Forearm deep flexor muscle thickness measured by B-mode ultrasonography (millimeters)
|
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Yhteistyökumppanit ja tutkijat
Tutkijat
- Opintojen puheenjohtaja: Elem Yorulmaz, Prof, Haydarpasa Numune Training and Research Hospital
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muut tutkimustunnusnumerot
- HNEAH-KAEK 2024/44
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .