Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Ultrasonographic Effects of Fascia Correction Kinesiotaping

9 de julio de 2026 actualizado por: Elem Yorulmaz, Haydarpasa Numune Training and Research Hospital

Investigation of the Physiological Effects of Fascia Correction Kinesiotaping in Healthy Adults: An Ultrasonographic Study

Single-center, within-subject repeated-measures study The aim of the present study was to investigate the acute effects of kinesiotaping applied using the fascia correction technique with different tension levels on fascial layers and associated musculature in healthy individuals.

Outcome measurements. The primary outcome was the ultrasonographically measured thickness of the fascial layers, while secondary outcomes included the thickness of the superficial and deep flexor muscle layers and the subcutaneous tissue.

Descripción general del estudio

Estado

Terminado

Condiciones

Intervención / Tratamiento

Descripción detallada

The fascial system plays an important role in force transmission, movement coordination, and interaction between musculoskeletal structures. Kinesiotaping is a commonly used therapeutic approach in rehabilitation, and the fascia correction technique has been proposed to influence fascial mobility and mechanical properties. However, the acute effects of different kinesiotape tension levels applied with the fascia correction technique on fascial and underlying musculoskeletal structures remain unclear.This single-center, within-subject repeated-measures study aims to investigate the immediate effects of kinesiotaping applied using the fascia correction technique with different tension levels on fascial layers and associated soft tissues in healthy individuals.

Healthy volunteers aged 18 years or older will be included. Participants will undergo kinesiotape application with different tension levels according to the study protocol. Ultrasonographic assessments will be performed to evaluate changes in fascial layer thickness as the primary outcome. Secondary outcomes will include ultrasonographic measurements of superficial and deep flexor muscle thickness and subcutaneous tissue thickness.

The study is designed to provide objective ultrasonographic measurements of acute tissue responses following kinesiotaping application and to improve understanding of the potential mechanical effects of the fascia correction technique on fascial and musculoskeletal structures.

Tipo de estudio

Intervencionista

Inscripción (Actual)

80

Fase

  • No aplica

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

      • Istanbul, Turquía (Türkiye)
        • Haydarpasa Numune Training and Research Hospital

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto

Acepta Voluntarios Saludables

Sí

Descripción

Inclusion Criteria:

A total of 80 healthy volunteers aged 18 years or older were included in the study. Participants had no current or previous serious musculoskeletal injury, pain, or neurological disorder affecting the upper extremity within the past six months

Exclusion Criteria:

Individuals were excluded if they were pregnant; regularly participated in high-level athletic training or competitive sports, had a history of skin allergy to adhesive materials; or had previous kinesiotaping application within the last month.

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Poner en pantalla
  • Asignación: N / A
  • Modelo Intervencionista: Asignación de un solo grupo
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Experimental: Healthy Volunteers
Participants received kinesiotaping using the fascia correction technique at different tension levels according to the study protocol. Each participant underwent all intervention conditions, and ultrasonographic measurements were performed before and after each application.
Fascia correction technique kinesiotaping

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
The superficial antebrachial fascia thickness
Periodo de tiempo: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
ultrasonographic measurements were obtained from the dominant forearm at the mid-forearm level. the hyperechoic linear structure separating the subcutaneous tissue from the superficial flexor muscles was defined as superficial antebrachial fascia thickness
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
The deep antebrachial fascia thickness
Periodo de tiempo: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Ultrasonographic measurements were obtained from the dominant forearm at the mid-forearm level. the hyperechoic linear structure separating the superficial and deep flxor muscles was defined as superficial antebrachial fascia thickness
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
the subcutaneous tissue thickness
Periodo de tiempo: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Subcutaneous tissue thickness measured by B-mode ultrasonography (millimeters)
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Forearm Superficial Flexor Muscle Thickness
Periodo de tiempo: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Forearm superficial flexor muscle thickness measured by B-mode ultrasonography (millimeters)
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Forearm deep flexor muscle thickness measured by B-mode ultrasonography (millimeters)
Periodo de tiempo: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Forearm deep flexor muscle thickness measured by B-mode ultrasonography (millimeters)
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Investigadores

  • Silla de estudio: Elem Yorulmaz, Prof, Haydarpasa Numune Training and Research Hospital

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

1 de mayo de 2024

Finalización primaria (Actual)

30 de agosto de 2024

Finalización del estudio (Actual)

30 de agosto de 2024

Fechas de registro del estudio

Enviado por primera vez

9 de julio de 2026

Primero enviado que cumplió con los criterios de control de calidad

9 de julio de 2026

Publicado por primera vez (Actual)

15 de julio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

15 de julio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

9 de julio de 2026

Última verificación

1 de julio de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • HNEAH-KAEK 2024/44

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir