Ultrasonographic Effects of Fascia Correction Kinesiotaping
Investigation of the Physiological Effects of Fascia Correction Kinesiotaping in Healthy Adults: An Ultrasonographic Study
Single-center, within-subject repeated-measures study The aim of the present study was to investigate the acute effects of kinesiotaping applied using the fascia correction technique with different tension levels on fascial layers and associated musculature in healthy individuals.
Outcome measurements. The primary outcome was the ultrasonographically measured thickness of the fascial layers, while secondary outcomes included the thickness of the superficial and deep flexor muscle layers and the subcutaneous tissue.
Visão geral do estudo
Descrição detalhada
The fascial system plays an important role in force transmission, movement coordination, and interaction between musculoskeletal structures. Kinesiotaping is a commonly used therapeutic approach in rehabilitation, and the fascia correction technique has been proposed to influence fascial mobility and mechanical properties. However, the acute effects of different kinesiotape tension levels applied with the fascia correction technique on fascial and underlying musculoskeletal structures remain unclear.This single-center, within-subject repeated-measures study aims to investigate the immediate effects of kinesiotaping applied using the fascia correction technique with different tension levels on fascial layers and associated soft tissues in healthy individuals.
Healthy volunteers aged 18 years or older will be included. Participants will undergo kinesiotape application with different tension levels according to the study protocol. Ultrasonographic assessments will be performed to evaluate changes in fascial layer thickness as the primary outcome. Secondary outcomes will include ultrasonographic measurements of superficial and deep flexor muscle thickness and subcutaneous tissue thickness.
The study is designed to provide objective ultrasonographic measurements of acute tissue responses following kinesiotaping application and to improve understanding of the potential mechanical effects of the fascia correction technique on fascial and musculoskeletal structures.
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Istanbul, Turquia (Türkiye)
- Haydarpasa Numune Training and Research Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
A total of 80 healthy volunteers aged 18 years or older were included in the study. Participants had no current or previous serious musculoskeletal injury, pain, or neurological disorder affecting the upper extremity within the past six months
Exclusion Criteria:
Individuals were excluded if they were pregnant; regularly participated in high-level athletic training or competitive sports, had a history of skin allergy to adhesive materials; or had previous kinesiotaping application within the last month.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Triagem
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Healthy Volunteers
Participants received kinesiotaping using the fascia correction technique at different tension levels according to the study protocol.
Each participant underwent all intervention conditions, and ultrasonographic measurements were performed before and after each application.
|
Fascia correction technique kinesiotaping
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
The superficial antebrachial fascia thickness
Prazo: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
ultrasonographic measurements were obtained from the dominant forearm at the mid-forearm level.
the hyperechoic linear structure separating the subcutaneous tissue from the superficial flexor muscles was defined as superficial antebrachial fascia thickness
|
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
|
The deep antebrachial fascia thickness
Prazo: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Ultrasonographic measurements were obtained from the dominant forearm at the mid-forearm level.
the hyperechoic linear structure separating the superficial and deep flxor muscles was defined as superficial antebrachial fascia thickness
|
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
the subcutaneous tissue thickness
Prazo: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Subcutaneous tissue thickness measured by B-mode ultrasonography (millimeters)
|
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
|
Forearm Superficial Flexor Muscle Thickness
Prazo: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Forearm superficial flexor muscle thickness measured by B-mode ultrasonography (millimeters)
|
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
|
Forearm deep flexor muscle thickness measured by B-mode ultrasonography (millimeters)
Prazo: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Forearm deep flexor muscle thickness measured by B-mode ultrasonography (millimeters)
|
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Cadeira de estudo: Elem Yorulmaz, Prof, Haydarpasa Numune Training and Research Hospital
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
- HNEAH-KAEK 2024/44
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .