Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Ultrasonographic Effects of Fascia Correction Kinesiotaping

9 июля 2026 г. обновлено: Elem Yorulmaz, Haydarpasa Numune Training and Research Hospital

Investigation of the Physiological Effects of Fascia Correction Kinesiotaping in Healthy Adults: An Ultrasonographic Study

Single-center, within-subject repeated-measures study The aim of the present study was to investigate the acute effects of kinesiotaping applied using the fascia correction technique with different tension levels on fascial layers and associated musculature in healthy individuals.

Outcome measurements. The primary outcome was the ultrasonographically measured thickness of the fascial layers, while secondary outcomes included the thickness of the superficial and deep flexor muscle layers and the subcutaneous tissue.

Обзор исследования

Статус

Завершенный

Условия

Вмешательство/лечение

Подробное описание

The fascial system plays an important role in force transmission, movement coordination, and interaction between musculoskeletal structures. Kinesiotaping is a commonly used therapeutic approach in rehabilitation, and the fascia correction technique has been proposed to influence fascial mobility and mechanical properties. However, the acute effects of different kinesiotape tension levels applied with the fascia correction technique on fascial and underlying musculoskeletal structures remain unclear.This single-center, within-subject repeated-measures study aims to investigate the immediate effects of kinesiotaping applied using the fascia correction technique with different tension levels on fascial layers and associated soft tissues in healthy individuals.

Healthy volunteers aged 18 years or older will be included. Participants will undergo kinesiotape application with different tension levels according to the study protocol. Ultrasonographic assessments will be performed to evaluate changes in fascial layer thickness as the primary outcome. Secondary outcomes will include ultrasonographic measurements of superficial and deep flexor muscle thickness and subcutaneous tissue thickness.

The study is designed to provide objective ultrasonographic measurements of acute tissue responses following kinesiotaping application and to improve understanding of the potential mechanical effects of the fascia correction technique on fascial and musculoskeletal structures.

Тип исследования

Интервенционный

Регистрация (Действительный)

80

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Места учебы

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

  • Взрослый

Принимает здоровых добровольцев

Да

Описание

Inclusion Criteria:

A total of 80 healthy volunteers aged 18 years or older were included in the study. Participants had no current or previous serious musculoskeletal injury, pain, or neurological disorder affecting the upper extremity within the past six months

Exclusion Criteria:

Individuals were excluded if they were pregnant; regularly participated in high-level athletic training or competitive sports, had a history of skin allergy to adhesive materials; or had previous kinesiotaping application within the last month.

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Скрининг
  • Распределение: Н/Д
  • Интервенционная модель: Одногрупповое задание
  • Маскировка: Нет (открытая этикетка)

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: Healthy Volunteers
Participants received kinesiotaping using the fascia correction technique at different tension levels according to the study protocol. Each participant underwent all intervention conditions, and ultrasonographic measurements were performed before and after each application.
Fascia correction technique kinesiotaping

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
The superficial antebrachial fascia thickness
Временное ограничение: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
ultrasonographic measurements were obtained from the dominant forearm at the mid-forearm level. the hyperechoic linear structure separating the subcutaneous tissue from the superficial flexor muscles was defined as superficial antebrachial fascia thickness
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
The deep antebrachial fascia thickness
Временное ограничение: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Ultrasonographic measurements were obtained from the dominant forearm at the mid-forearm level. the hyperechoic linear structure separating the superficial and deep flxor muscles was defined as superficial antebrachial fascia thickness
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
the subcutaneous tissue thickness
Временное ограничение: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Subcutaneous tissue thickness measured by B-mode ultrasonography (millimeters)
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Forearm Superficial Flexor Muscle Thickness
Временное ограничение: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Forearm superficial flexor muscle thickness measured by B-mode ultrasonography (millimeters)
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Forearm deep flexor muscle thickness measured by B-mode ultrasonography (millimeters)
Временное ограничение: Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications
Forearm deep flexor muscle thickness measured by B-mode ultrasonography (millimeters)
Baseline and 30 minutes after two different interventions (different tensions). A one-week washout period was implemented between applications

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Следователи

  • Учебный стул: Elem Yorulmaz, Prof, Haydarpasa Numune Training and Research Hospital

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

1 мая 2024 г.

Первичное завершение (Действительный)

30 августа 2024 г.

Завершение исследования (Действительный)

30 августа 2024 г.

Даты регистрации исследования

Первый отправленный

9 июля 2026 г.

Впервые представлено, что соответствует критериям контроля качества

9 июля 2026 г.

Первый опубликованный (Действительный)

15 июля 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

15 июля 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

9 июля 2026 г.

Последняя проверка

1 июля 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Другие идентификационные номера исследования

  • HNEAH-KAEK 2024/44

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕТ

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться