Tämä sivu käännettiin automaattisesti, eikä käännösten tarkkuutta voida taata. Katso englanninkielinen versio lähdetekstiä varten.

Macular Resurfacing Using Autologous ILM Patch Transposition for Idiopathic Epiretinal Membrane

lauantai 15. elokuuta 2026 päivittänyt: Peiquan Zhao, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine

Macular Resurfacing With Non-Inverted Autologous Internal Limiting Membrane Patch Transposition for Idiopathic Epiretinal Membrane: A Multidimensional Evaluation of Efficacy and Foveal Microstructural Remodeling

Idiopathic epiretinal membrane is a condition in which abnormal tissue grows on the surface of the retina and can cause blurred vision and distortion. The standard surgical treatment is removal of this membrane, but some patients may not achieve complete visual recovery because the normal structure of the central retina may not fully restore after surgery.

This study is a prospective randomized controlled trial designed to evaluate a new surgical technique called macular resurfacing using an autologous internal limiting membrane patch transposition. The technique uses a patient's own retinal tissue to cover the macular area after epiretinal membrane removal, with the aim of promoting more natural healing of the retinal surface.

Patients with idiopathic epiretinal membrane will be randomly assigned to receive either the new surgical technique or conventional epiretinal membrane peeling. Visual function and retinal structural changes will be evaluated using visual examinations and multimodal retinal imaging during follow-up. The study aims to determine whether this new technique can improve visual outcomes and promote better restoration of macular microstructure.

Tutkimuksen yleiskatsaus

Opintotyyppi

Interventio

Ilmoittautuminen (Arvioitu)

90

Vaihe

  • Ei sovellettavissa

Osallistumiskriteerit

Tutkijat etsivät ihmisiä, jotka sopivat tiettyyn kuvaukseen, jota kutsutaan kelpoisuuskriteereiksi. Joitakin esimerkkejä näistä kriteereistä ovat henkilön yleinen terveydentila tai aiemmat hoidot.

Kelpoisuusvaatimukset

Opintokelpoiset iät

  • Aikuinen
  • Vanhempi Aikuinen

Hyväksyy terveitä vapaaehtoisia

Ei

Kuvaus

Inclusion Criteria:

  • Diagnosis of epiretinal membrane confirmed by Spectral-domain Optical Coherence Tomography
  • Best corrected visual acuity <= 0.8 (equivalent to 0.1 LogMAR)
  • Presence of metamorphopsia confirmed by Amsler grid testing
  • Ability to understand the study information and provide written informed consent voluntarily

Exclusion Criteria:

  • History of intraocular surgery, with the exception of uncomplicated cataract surgery
  • Presence of any of the following ocular diseases: retinal vascular diseases (including diabetic retinopathy, retinal hemangioma, retinal vascular occlusion, Coats' disease, etc.), uveitis, macular degeneration, macular hole, retinal detachment, retinoschisis, pathologic myopia, ocular trauma, intraocular tumor and neurofibromatosis.

Opintosuunnitelma

Tässä osiossa on tietoja tutkimussuunnitelmasta, mukaan lukien kuinka tutkimus on suunniteltu ja mitä tutkimuksella mitataan.

Miten tutkimus on suunniteltu?

Suunnittelun yksityiskohdat

  • Ensisijainen käyttötarkoitus: Hoito
  • Jako: Satunnaistettu
  • Inventiomalli: Rinnakkaistehtävä
  • Naamiointi: Kolminkertaistaa

Aseet ja interventiot

Osallistujaryhmä / Arm
Interventio / Hoito
Kokeellinen: Non-Inverted Autologous ILM Patch Transposition Group
After standard pars plana vitrectomy and epiretinal membrane removal, the internal limiting membrane (ILM) was peeled from the central fovea to the vascular arcades. A piece of healthy ILM free of ERM from the paramacular region was prepared as a patch for subsequent coverage, while its pedicle remained anchored to the paramacular site. A perfluorocarbon liquid bubble was injected into the vitreous cavity to flatten the ILM patch and facilitate manipulation. The patch was then detached and carefully transposed to resurface the macular area.
Active Comparator: Conventional ERM/ILM Peeling Group
After standard pars plana vitrectomy and epiretinal membrane removal, the ILM was peeled from the central fovea to the vascular arcades, without additional ILM patch transplantation.

Mitä tutkimuksessa mitataan?

Ensisijaiset tulostoimenpiteet

Tulosmittaus
Aikaikkuna
Best Corrected Visual Acuity
Aikaikkuna: From baseline to 12 months
From baseline to 12 months

Yhteistyökumppanit ja tutkijat

Täältä löydät tähän tutkimukseen osallistuvat ihmiset ja organisaatiot.

Opintojen ennätyspäivät

Nämä päivämäärät seuraavat ClinicalTrials.gov-sivustolle lähetettyjen tutkimustietueiden ja yhteenvetojen edistymistä. National Library of Medicine (NLM) tarkistaa tutkimustiedot ja raportoidut tulokset varmistaakseen, että ne täyttävät tietyt laadunvalvontastandardit, ennen kuin ne julkaistaan ​​julkisella verkkosivustolla.

Opi tärkeimmät päivämäärät

Opiskelun aloitus (Arvioitu)

Torstai 10. syyskuuta 2026

Ensisijainen valmistuminen (Arvioitu)

Maanantai 9. elokuuta 2027

Opintojen valmistuminen (Arvioitu)

Keskiviikko 9. elokuuta 2028

Opintoihin ilmoittautumispäivät

Ensimmäinen lähetetty

Keskiviikko 12. elokuuta 2026

Ensimmäinen toimitettu, joka täytti QC-kriteerit

Keskiviikko 12. elokuuta 2026

Ensimmäinen Lähetetty (Todellinen)

Maanantai 17. elokuuta 2026

Tutkimustietojen päivitykset

Viimeisin päivitys julkaistu (Todellinen)

Tiistai 18. elokuuta 2026

Viimeisin lähetetty päivitys, joka täytti QC-kriteerit

Lauantai 15. elokuuta 2026

Viimeksi vahvistettu

Lauantai 1. elokuuta 2026

Lisää tietoa

Tähän tutkimukseen liittyvät termit

Muut tutkimustunnusnumerot

  • XH-2026-042

Lääke- ja laitetiedot, tutkimusasiakirjat

Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta

Ei

Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta

Ei

Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .

Tilaa