- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT07789665
Auditory Intranerve Stimulation Perceptual Study (ANI-NIH)
Scientific Assessment of Auditory Intranerve Stimulation Loudness and Pitch Percepts
Tutkimuksen yleiskatsaus
Yksityiskohtainen kuvaus
The auditory nerve implant (ANI) targets the auditory nerve directly between the cochlea and the brainstem, whereas current implants like the cochlear and brainstem implants stimulate the cochlea or brainstem, respectively. By providing direct stimulation within the auditory nerve, a nerve implant offers a better electrode-nerve interface and may achieve improved hearing compared to a cochlear or brainstem implant. Preliminary results in animals, computer simulations, and acute clinical studies showed significantly better performance compared to other hearing aidsoptions. This study aims to investigate the extent to which these benefits are perceptible in the human auditory nerve.
The primary goal of this study is to gain scientific insight into the hearing experience with the direct auditory nerve stimulation. However, the results could contribute to the development of new hearing implants that directly stimulate the auditory nerve.
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskeluyhteys
- Nimi: Hubert Lim, Prof.
- Puhelinnumero: +16126264565
- Sähköposti: Hlim@umn.edu
Opiskelupaikat
-
-
-
Hanover, Saksa, 30625
- Rekrytointi
- Hannover Medical School
-
Ottaa yhteyttä:
- Karl-Heinz Dyballa
- Puhelinnumero: +4917615328589
- Sähköposti: dybala.karl-heinz@mh-hannover.de
-
Alatutkija:
- Rolf Salcher, Dr.
-
Alatutkija:
- Max Timm, Dr
-
Alatutkija:
- Waldo Nogueira, Prof.
-
Alatutkija:
- Karl-Heinz Dyballa, Dr.
-
Päätutkija:
- Thomas Lenarz, Prof.
-
Hanover, Saksa, 30625
- Aktiivinen, ei rekrytointi
- Service provider for the performance of surgical procedures: International Neuroscience Institute
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
- Vanhempi Aikuinen
Hyväksyy terveitä vapaaehtoisia
Kuvaus
Inclusion Criteria:
- Age ≥18 and ≤85 years
- Written informed consent
- Bilateral deafness with cochlea that does not allow the implantation of a cochlear implant (CI). This can include ossification, malformation of cochlea; poor CI performers (lowest quartile of CI performance); and patientparticipants with facial nerve stimulation using a CI which is not manageable without reduction of performance
- Eligible for routine auditory brainstem implant (ABI) where patientparticipants would undergo more invasive brainstem surgery than the ANI surgery
- Functional auditory nerve and central auditory pathway
- Post-linguistic onset of ipsilateral severe-to-profound hearing loss
- The contralateral ear has sufficient vestibular function
Women not able to become pregnant*
Women not able to become pregnant defined as follows:
- at least 6 weeks after surgical sterilization by bilateral tubal ligation or bilateral oophorectomy or
- hysterectomy or uterine agenesis or
- ≥ 50 years and in postmenopausal state > 1 year or
- < 50 years and in postmenopausal state > 1 year with serum FSH > 40 IU/l and serum estrogen < 30 ng/l or a negative estrogen test, both at screening
Exclusion Criteria:
- Medical, neurological, or psychological conditions that would contraindicate undergoing surgery, e.g. depression, acute cardiac infarction, history of stroke, dementia, epilepsy
- Additional handicaps that would prevent participation in evaluations
- Women able to become pregnant
- Pregnant women
- Persons who are deprived of their liberty on the basis of an official order or a court order or authorization
- Known allergies to one of the components of the implant (medical grade silicone, Parylene-C, Iridium oxide, Platinum-Iridium alloy (PtIr 10) and (PtIr 20) )
- Other active devices with potential interference with the auditory nerve implant
- Presence of anatomic abnormalities that would prevent appropriate placement of the stimulator housing in the bone of the skull
- Additionally, in the event of other health issues, the investigators will decide on a case-by-case basis whether to enroll the patientparticipant in the study
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Laitteen toteutettavuus
- Jako: Ei käytössä
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Kokeellinen: Experimental: Direct Auditory Nerve Stimulation
Patients Participants will be implanted with an Auditory Nerve Implant (ANI) for one year to evaluate key perceptual measures of temporary direct auditory nerve stimulation.
Safety and efficacy will also be evaluated, as well as different speech perception capabilities.
|
The investigational research device consists of a speech processor worn on the ear and an implant body with an electrode array.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Pitch perception performance of ANI
Aikaikkuna: 12 months
|
Systematic place pitch ordering maintained on month 12
|
12 months
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Loudness perception performance of ANI
Aikaikkuna: 12 months
|
Collection of loudness growth functions (LGFs) across single electrodes that have a dynamic range greater than 6 dB and maintained on month 12
|
12 months
|
Muut tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Frequency Resolution
Aikaikkuna: 12 months
|
Minimum frequency specificity (i.e., current spread) of electrodes is narrower than 0.8 mm in bandwidth maintained on month 12
|
12 months
|
|
Position of ANI electrode array in auditory nerve
Aikaikkuna: 12 months
|
Evaluation of the final position of the ANI electrode array.
The number of electrodes eliciting auditory activation will be measured.
The stability of the percepts elicited will also be measured.
Both of these measurements provide the stability of the electrode array implanted within the auditory nerve.
|
12 months
|
|
Collection of adverse events
Aikaikkuna: 12 months
|
Collection of adverse events during the evaluation period
|
12 months
|
Yhteistyökumppanit ja tutkijat
Sponsori
Tutkijat
- Päätutkija: Thomas Lenarz, Prof., Hannover Medical School
- Päätutkija: Amir Samii, Prof., International Neuroscience Institute Hannover
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Arvioitu)
Ensisijainen valmistuminen (Arvioitu)
Opintojen valmistuminen (Arvioitu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- 0000509678
- No.11979-BO-MPDG-M-2025 (Muu tunniste: Ethics committee Hannover Medical School)
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .