- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT07860346
Development of an Improved Method of Measuring Total Body Bone Perfusion Using Total-body PET/CT
Broken bones (fractures) are a common problem in several serious health conditions, such as osteoporosis, kidney failure, and sickle cell disease. To better understand and treat these diseases, researchers need a reliable way to measure how much blood flows through our bones.
In animal studies, a special scan called PET (Positron Emission Tomography) has been used successfully to measure bone blood flow. This scan uses a safe, low dose of a radioactive substance called sodium fluoride, which helps show how blood moves through the bones. However, using this method in people has been difficult in the past because older PET scanners were not sensitive enough to give accurate results.
Recently, St Thomas' Hospital in London has received two new, state-of-the-art PET scanners. These scanners can take pictures of the whole body at once and are much more sensitive than older models. They can also take images of the heart during the scan, which is important because it allows researchers to measure how much of the radioactive tracer is being delivered to the bones through the bloodstream. This is a big improvement over older, more invasive methods that required taking many blood samples.
The main goal of this pilot study is to develop a better, more reliable way to measure bone blood flow in healthy volunteers using these new PET scanners. The researchers also want to check if measuring the tracer in the heart is as good as, or better than, the previous method of taking frequent blood samples.
To do this, the researchers will invite ten healthy volunteers-men and postmenopausal women over the age of 50-to take part in our study. Each volunteer will have a one-hour PET/CT scan, which takes images from the head down to the upper thighs after a small injection of the radioactive tracer. To compare the new method with the old one, the researchers will also take five small blood samples from the volunteer's arm at different times during the scan.
The research team hope that this study will lead to better ways of studying and treating bone diseases in the future, making the process easier and less invasive for patients.
Tutkimuksen yleiskatsaus
Tila
Yksityiskohtainen kuvaus
This is a prospective single centre non-randomised exploratory pilot study. Ten healthy volunteers aged over 50 years will be recruited via the King's College London (KCL) research recruitment page and circular email sent to KCL staff. Each healthy volunteer will have a 1-hour dynamic TB-PET/CT scan from vertex to mid-thighs following a bolus injection of 90 MBq of [18F]-sodium fluoride ([18F]-NaF) to measure bone perfusion (K1) and regional bone plasma clearance (Ki). Five venous blood samples will be collected at 5, 15, 30, 45, and 60 minutes after injection. These will be used to verify the left ventricle (LV) measurements of the arterial input function (AIF) from the image of the heart, and correct the whole blood measurements in the LV to measurements of plasma concentration.
Opintotyyppi
Ilmoittautuminen (Arvioitu)
Yhteystiedot ja paikat
Opiskeluyhteys
- Nimi: Amelia Moore, PhD
- Puhelinnumero: +44 0207 188 4092
- Sähköposti: amelia.moore@kcl.ac.uk
Opiskelupaikat
-
-
-
London, Yhdistynyt kuningaskunta, SE1 9RT
- Rekrytointi
- King's College London
-
Ottaa yhteyttä:
- Amelia Moore, PhD
- Sähköposti: amelia.moore@kcl.ac.uk
-
Päätutkija:
- Prof. Gary Cook
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Näytteenottomenetelmä
Tutkimusväestö
Ten healthy volunteers aged over 50 years old
Kuvaus
Inclusion Criteria:
- 5 male and 5 female healthy volunteers aged over 50 years
- No metabolic bone disease (e.g. osteoporosis)
- No metastatic bone disease
- Good venous access
- Must be able to lie flat and remain motionless for the duration of the scan (60 minutes)
- Good bladder control
Exclusion Criteria:
- Over 1.85 metres (6.1 feet) in height to ensure adequate skeletal coverage
- Over 95 kg (15 stone) in weight to ensure image quality
- Claustrophobia
- Uncontrolled high blood pressure
- Presence of any metal in the body or heart pacemaker
- Pregnant women
- Not currently or previously been involved within the last 12 months on trials investigating other imaging methods involving ionising radiation
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Havaintomallit: OTHER
- Aikanäkymät: PROSPECTIVE
Kohortit ja interventiot
Ryhmä/Kohortti |
Interventio / Hoito |
|---|---|
|
Healthy volunteers aged over 50 years
Will undergo 1-hour PET/CT scan |
Each volunteer will have a 1-hour dynamic TB-PET/CT scan from vertex to mid-thighs following a bolus injection of 90 MBq of [18F]-sodium fluoride ([18F]-NaF) to measure bone perfusion (K1) and regional bone plasma clearance (Ki). |
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
To measure bone perfusion (K1) and bone plasma clearance (Ki) with [18F]-sodium fluoride TB-PET/CT at multiple sites across the whole skeleton in 10 healthy volunteers, both are measured in units of mL per min per mL.
Aikaikkuna: 1 month
|
Dynamic [18F]-sodium fluoride PET/CT scans can measure both effective bone plasma flow (K1), and bone plasma clearance (Ki), the latter reflecting regional bone formation. Both are measured in units of mL per min per mL (or mL min-¹ mL-¹), which signifies the volume of plasma cleared of the tracer per minute per unit volume of tissue. |
1 month
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
To develop an improved method of measuring the arterial input function (AIF) by using a volume of interest (VOI) in the left ventricle (LV) of the heart in the same 10 healthy volunteers.
Aikaikkuna: 1 month
|
This is an important secondary outcome because both K1 and Ki require knowing the arterial input function (AIF), which is essentially how much tracer is available to the bone. Previously, the only accurate way of measuring this was by direct arterial blood sampling, which is an invasive procedure, and an alternative technique was to derive a semi-population input function. However, the new scanners include the heart in the field of view enabling the AIF to be measured more reliably, and the researchers hope that this will significantly improve the measurement of bone blood flow and bone formation in the future. |
1 month
|
Yhteistyökumppanit ja tutkijat
Sponsori
Yhteistyökumppanit
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Arvioitu)
Opintojen valmistuminen (Arvioitu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muut tutkimustunnusnumerot
- 368515
- OPP1122 (Muu apuraha/rahoitusnumero: National PET imaging platform research pilot funding (MRC))
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
IPD-suunnitelman kuvaus
This is a pilot study only in healthy volunteers
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .