- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT00407693
PET Whole Body Imaging Using a Peripheral Benzodiazepine Receptor Ligand [C-11]PBR28
Aperçu de l'étude
Description détaillée
The peripheral benzodiazepine receptor (PBR) is distinct from central benzodiazepine receptors associated with GABA(A) receptors. Although PBR was initially identified in peripheral organs such as kidneys, endocrine glands and lungs, later studies identified PBR in the central nervous system. In normal conditions, PBR is expressed in low levels in some neurons and glial cells. PBR can be a clinically useful marker to detect neuroinflammation because activated microglial cells in inflammatory areas express much greater levels of PBR than in microglial cells in resting conditions.
PBR has been imaged with positron emission tomography (PET) using [(11)C]1-(2-chlorophenyl-N-methylpropyl)-3-isoquinoline carboxamide (PK11195). However, this classical ligand provides only low levels of specific signals and is not sensitive to detect changes that occurred in vivo. Recently we developed a new ligand, N-acetyl-N-(2-[(11)C]methoxybenzyl)-2-phenoxy-5-pyridinamine [(11)C]PBR28), which showed much greater specific signals than [(11)C]PK11195 in non-human primates. Therefore, [(11)C]PBR28 is a promising PET ligand. However, radiation absorbed doses have not been estimated from human whole body imaging.
The initial purpose of this protocol is to estimate radiation absorbed doses of [11C]PBR28 by performing whole body imaging studies on ten healthy human subjects. The radiation absorbed doses are required to apply this PET ligand in various neurological and psychiatric disorders in the future.
Under the current and other protocols using [(11)C]PBR28, we found that some healthy subjects and patients have very low to no binding of [(11)C]PBR28. We studied approximately 188 subjects in total under protocols using [11C]PBR28 and found that 8.5% (16/188) had almost no binding of [(11)C]PBR28. Several published ligands have been tested and all of the tested ligands recently developed show low affinity to a subset of humans. By using [(11)C]PBR28, we need to exclude PBR28 nonbinders from the data to study changes in PBR. By using a PET ligand that binds equally to PBR28 binders and nonbinders, we would be able to study all subjects. We also confirmed that PBR28 nonbinders determined by PET do not show binding in in vitro binding assays using blood cells.
We wish to test new ligands currently being developed in our chemistry group by obtaining blood samples from additional PBR28 nonbinders (= low affinity binders) and by performing in vitro binding assays. Because our preliminary analysis of whole body imaging has shown that the differences between PBR28 binders and nonbinders might somewhat vary among organs and the cause of the nonbinding phenomenon is not fully understood, after identifying PBR28 nonbinders by binding assays, we will perform whole body imaging using [(11)C]PBR28.
Type d'étude
Inscription (Réel)
Phase
- La phase 1
Contacts et emplacements
Lieux d'étude
-
-
Maryland
-
Bethesda, Maryland, États-Unis, 20892
- National Institutes of Health Clinical Center, 9000 Rockville Pike
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
- INCLUSION CRITERIA:
All subjects must be healthy and aged 18-65 years.
EXCLUSION CRITERIA:
- Current psychiatric disease, substance abuse or severe systemic disease based on history and physical exam.
- Laboratory tests with clinically significant abnormalities.
- Prior participation in other research protocols or clinical care in the last year such that radiation exposure including that from this protocol would exceed the guidelines set by the Radiation Safety Committee (RSC).
- Pregnancy and breast feeding.
- Positive HIV test.
- Cannot lie flat for 2 - 3 h.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: Non randomisé
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
|---|
|
Biodistribution of [C-11]PBR28
|
Collaborateurs et enquêteurs
Publications et liens utiles
Publications générales
- Anholt RR, De Souza EB, Oster-Granite ML, Snyder SH. Peripheral-type benzodiazepine receptors: autoradiographic localization in whole-body sections of neonatal rats. J Pharmacol Exp Ther. 1985 May;233(2):517-26.
- Anholt RR, Murphy KM, Mack GE, Snyder SH. Peripheral-type benzodiazepine receptors in the central nervous system: localization to olfactory nerves. J Neurosci. 1984 Feb;4(2):593-603. doi: 10.1523/JNEUROSCI.04-02-00593.1984.
- Anholt RR, Pedersen PL, De Souza EB, Snyder SH. The peripheral-type benzodiazepine receptor. Localization to the mitochondrial outer membrane. J Biol Chem. 1986 Jan 15;261(2):576-83.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- 070035
- 07-M-0035
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .