Magnetic Resonance-Guided High Intensity Focused Ultrasound for Palliation of Painful Skeletal Metastases

28 août 2012 mis à jour par: Philips Healthcare

Magnetic Resonance-Guided High Intensity Focused Ultrasound for Palliation of Painful Skeletal Metastases - A Pilot Study

This study is to confirm the safety and technical of MRI guided High Intensity Focused Ultrasound (HIFU) for Palliation for Pain of Skeletal Metastases.

MRI guided high intensity focused ultrasound uses ultrasound to heat and thermally ablate tissue. The MRI system identifies the ultrasound path and monitors heat rise in the tissue. The goal of the study is to show treatment safety and effectiveness. MR-guided HIFU will be performed in patients who pass inclusion/exclusion criteria.

Aperçu de l'étude

Statut

Complété

Les conditions

Description détaillée

Bone metastases are common among patients with advanced cancer and have been reported in up to 85% of cancer patients at autopsy. Complications of bone metastases include pain, functional limitation, decreased quality of life, pathological fracture, spinal cord compression and cauda equina syndrome.

External beam radiotherapy is the current standard treatment for patients with painful uncomplicated bone metastases. Unfortunately up to 30 % of patients treated with radiotherapy do not respond to therapy, and 30% of responders have their pain recur at some point after treatment. Radiotherapy re-treatment is also limited by cumulative doses delivered to sensitive structures. Ablative techniques such as cryotherapy and percutaneous radiofrequency ablation are not similarly limited by cumulative effects, however, they are invasive procedures that place patients at risk of complications.

MR-guided high intensity focused ultrasound (MR-HIFU) is a non-invasive, outpatient modality being investigated for the treatment of cancer. In MR-HIFU, a specially designed transducer is used to focus a beam of ultrasound energy into a small volume at a specific target site in the body. The focused beam produces therapeutic hyperthermia in the target field but only harmlessly warms the immediately surrounding tissue. Magnetic resonance (MR) imaging is used both to focus the ultrasound beam on the target field in the bone (the metastatic lesion and adjacent periosteum containing the nerves and vasculature for the tumor) and to perform real-time thermal mapping at and around the target. The mechanism of action of pain response is thought to be thermal periosteal denervation and / or thermal ablation of the tumor mass that diminishes pressure on the surrounding tissue.

Type d'étude

Interventionnel

Inscription (Réel)

10

Phase

  • Phase 2
  • La phase 1

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Ontario
      • Toronto, Ontario, Canada, M4N 3M5
        • Sunnybrook Health Sciences Centre

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Age ≥18 years
  • Able to give informed consent
  • Weight <140kg
  • Radiologic evidence of bone metastases from any solid tumor
  • Able to characterize pain specifically at the site of interest (target lesion)
  • Pain score related to target lesion of ≥4 on a 0-10 point scale irrespective of medications
  • Target lesion accessible for MR-HIFU procedure
  • Target lesion maximum dimension ≤8cm
  • Target lesion is uncomplicated (i.e.: no fracture / spinal cord compression / cauda equina syndrome / soft tissue component)
  • Target lesion visible by non-contrast MRI
  • Interface between bone and skin lies ≥1cm from surface
  • Able to communicate sensation during MR-HIFU treatment
  • MR-HIFU treatment date ≥2 weeks from most recent treatment of primary tumor or any chemotherapy.

Exclusion Criteria:

  • Prior radiotherapy / surgery / ablative therapy / other local therapy to target lesion.
  • Unable to characterize pain specifically at the site of interest (target lesion)
  • Pregnant / Nursing woman
  • Target lesion is complicated (i.e.: presence of one of fracture / spinal cord compression / cauda equina syndrome / soft tissue component).
  • Target lesion <1cm from nerve bundles / bladder / bowel
  • Target lesion in contact with hollow viscera
  • Target lesion located in skull, spine (excluding sacrum which is allowed) or sternum
  • Scar along proposed HIFU beam path
  • Orthopaedic implant along proposed HIFU beam path or at site of target lesion.
  • Serious cardiovascular, neurological, renal or hematological chronic disease
  • Active infection
  • Unable to tolerate required stationary position during treatment
  • Allergy to MRI contrast agent or sedation

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: N / A
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Patients with painful bone metastasis
Patients with bone metastasis causing pain
HIFU is the use of focused ultrasound energy to penetrate through soft tissue and causes localized high temperatures (55°C to 70°C) for a few seconds within the target producing well defined regions of protein and nerve denaturation, irreversible cell damage, and coagulative necrosis.
Autres noms:
  • HIFU
  • Ablation
  • Ultrasons focalisés à haute intensité

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Reduction of Pain Score
Délai: 90 Days
Determine the efficacy of MR-Guided HIFU in reducing pain scores related to the site treated as measured on the Brief Pain Inventory (BPI).
90 Days
Reduction of Pain Medication
Délai: 90 Days
Determine the efficacy of MR-Guided HIFU in reducing pain medication usage
90 Days
Complications and Adverse Events
Délai: 90 Days
Document complications and adverse events as well as the number of unintended lesions that occur as a result of treatment with MR-Guided HIFU.
90 Days

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Changes in bone density
Délai: 90 Days
Measure changes in bone density between X-ray and CT images taken prior to and following treatment.
90 Days
Quality of Life
Délai: 90 Days
Measure patient quality of life using both the EORTC QLQ-BM22 and FACT-BP scales
90 Days

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Les enquêteurs

  • Chercheur principal: Greg Czarnota, M.D., Radiation Oncology, Sunnybrook Health Sciences Centre

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 janvier 2011

Achèvement primaire (Réel)

1 juin 2012

Achèvement de l'étude (Réel)

1 juin 2012

Dates d'inscription aux études

Première soumission

2 mars 2011

Première soumission répondant aux critères de contrôle qualité

3 mars 2011

Première publication (Estimation)

4 mars 2011

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Estimation)

29 août 2012

Dernière mise à jour soumise répondant aux critères de contrôle qualité

28 août 2012

Dernière vérification

1 août 2012

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • 02082011

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner