Functional Assessment of Coronary Artery Disease by CTA Flow Encoding
Aperçu de l'étude
Statut
Les conditions
Description détaillée
The purpose of this pilot study is to test the ability of Transluminal Flow Encoding (TAFE) to evaluate vessel specific ischemia in patients with a clinical indication for invasive coronary angiography (ICA) with fractional flow reserve (FFR) measurements for suspected coronary disease. TAFE is a novel method that derives coronary blood flow from easily obtainable non-invasive coronary CT angiograms.
Participants will undergo a rest coronary CTA, a regadenoson stress CT, and a clinically indicated invasive coronary angiogram. The study aims to determine the accuracy of TAFE compared to invasive fractional flow reserve.
We hypothesize that TAFE-derived coronary blood flow, coronary flow reserve, and myocardial CT perfusion imaging can accurately diagnose an abnormal FFR (<0.80) measured in vessels in patients undergoing invasive coronary angiography.
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
Maryland
-
Baltimore, Maryland, États-Unis, 21287
- Johns Hopkins University
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Inclusion Criteria A. Male or female patients, age 40 years and older. Women of child bearing potential must demonstrate a negative pregnancy test within 24 hours of the study CT.
B. Referral for invasive coronary angiography for a suspicion of coronary artery disease with possible percutaneous intervention planned.
C. Able to understand and willing to sign the Informed Consent Form.
Exclusion Criteria:
A. Patients with a known history of coronary artery bypass surgery. B. Current or previous ST elevation myocardial infarction (MI), prior MI (confirmed by persistent pathologic Q waves on ECG, clinical reports of CPK-MB or Troponin > three times the upper limit of normal or a fixed perfusion defect on nuclear imaging) C. Current evidence of acute myocardial ischemia, unstable angina, or cardiovascular instability including troponin > than the limit of detection (≥0.06 ng/ml), new ST depression > 1 mm, hypotension with a systolic pressure <90 mm Hg.
D. Known allergy to iodinated contrast media
E. Known or suspected intolerance or contraindication to beta-blockers including:
- Known allergy to beta-blockers
- History of moderate to severe bronchospastic lung disease (including moderate to severe asthma) F. Known allergy to regadenoson or aminophylline. G. Any patient not deemed medically stable by a physician. F. Known or suspected severe symptomatic aortic stenosis. G. Severe hypertrophic obstructive cardiomyopathy. H. Evidence of severe symptomatic heart failure (NYHA Class III or IV) at the time of the scan.
I. Inability to lie flat. J. Atrial fibrillation or uncontrolled tachyarrhythmia, or advanced atrioventricular block (second or third degree heart block) K. Elevated serum creatinine (> 1.5mg/dl) OR calculated creatinine clearance of < 60 ml/min (using the Cockcroft-Gault formula) L. History of contrast-induced nephropathy M. Severe pulmonary disease or other disorder that does not allow patient to hold breath for 10 seconds or more.
N. History of organ transplantation O. Acute myocarditis or pericarditis. P. Recent history of illicit drug use (past 3 months) Q. Recent use of dipyridamole containing medications. R. Current pregnancy.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Diagnostic Accuracy of Coronary Computed Tomography Angiography (CTA), myocardial CT perfusion and TAFE to predict invasive FFR
Délai: 2 years
|
We will test the diagnostic accuracy of Coronary CTA, myocardial CT perfusion, and transluminal attenuation flow encoding (TAFE) to predict fractional flow reserve (FFR). Coronary CTA and myocardial CT perfusion results will be dichotomous, either normal or abnormal. Coronary CTA will be defined as abnormal when there is a > or = 50% diameter stenosis in a coronary vessel. Myocardial CT perfusion will be defined as abnormal when there is a visually determined myocardial perfusion deficit. TAFE will be a continuous variable in units of ml/min. The reference standard will be invasive fractional flow reserve (FFR). FFR will be defined as abnormal when it is less than 0.80. |
2 years
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Diagnostic Accuracy of TAFE-derived coronary blood flow to predict invasive FFR
Délai: 2 years
|
We will test the diagnostic accuracy of TAFE derived coronary blood flow in ml/min to predict and abnormal FFR (<0.80)
|
2 years
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Armin R Zadeh, MD, Johns Hopkins University
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- NA_00091805
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .