Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Fluid Responsiveness Evaluation by AbdomiNal Compression in Kids Based on the STARLING Concept (FRANCK)

25 décembre 2016 mis à jour par: Matthias Jacquet-Lagrèze, Hopital Louis Pradel

Purpose:

Fluid responsiveness in a context of circulatory failure can be predicted by different way. Dynamic criteria such as pulse pressure variation, stroke volume variation during an end-expiratory occlusion maneuver or a passive leg raising have been reported to predict fluid responsiveness. Only aortic velocity peak variation measured with transthoracic echocardiography during mechanical ventilation has been reported to predict fluid responsiveness in children. Besides some physician use a maneuver of abdominal compression to predict fluid responsiveness in children with circulatory failure. This strategy has never been formally evaluated.

The investigators will study the diagnosis accuracy of the stroke volume variation induced by an abdominal compression to predict stroke volume variation after 10 ml/kg fluid load in children with circulatory failure.

Thirty-eight pediatric patients under eight years old in circulatory failure, for whom the attending physician has decided a fluid load will be included. Hemodynamic parameters: arterial pressure, heart rate, stroke volume measured with echocardiography; will be recorded. This data collection will be performed before, after abdominal compression and after a fluid load of 10 ml/kg.

Patients will be aposteriori sorted in two groups: Fluid responders and Fluid non-responders. Fluid responders are defined as patients that show an increase greater than 15 % in stroke volume. The diagnosis ability of the Stroke volume variation after an abdominal compression to predict fluid responsiveness will be investigate and receiving operative characteristic (ROC) curve will be built. The correlation between the variation of stroke volume during abdominal compression and during the fluid load will be studied. Other parameters such as arterial pressure and heart rate will also be investigated.

Aperçu de l'étude

Type d'étude

Observationnel

Inscription (Réel)

40

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Lyon, France
        • Intensive care and anesthesiology department, Hôpital Louis Pradel.
      • Lyon, France
        • Pediatric Intensive care, Hôpital Femme Mère Enfant

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

Pas plus vieux que 8 ans (Enfant)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Patient hospitalized in the intensive care unit of the hospital " feme mère enfant " or the cardiologic hospital of BRON who suffer from circulatory failure and for whom the attending physiscian has decided to administer a 10 ml/kg cristalloïd infusion.

La description

Inclusion Criteria:

  • Age < 8 years old
  • Patient with a circulatory failure defined as follow :

Treatment including vasopressor or inotrope

OR macrocirculatory failure

  • Heart rate > 2 Standard Deviation (SD)
  • Systolic arterial pressure < 2 SD
  • Mean arterial pressure < 2 SD
  • Diastolic arterial pressure < 2 SD

WITH signs of microcirculatory failure

  • Capillary refill time > 2 secondes
  • Blotch
  • Organ dysfunction due to the circulatory failure (Oliguria < 0,5 ml/kg/h, acute lung injury, encephalopathy)

Exclusion Criteria:

  • Opposition from the parents or the one who holds the parental authority
  • Cardiogenic acute pulmonary edema,
  • Extreme hemodynamic instability,
  • Intra-abdominal hypertension,
  • Recent abdominal surgery that does not permit an abdominal compression without causing pain.
  • Patient with mechanical circulatory support, such as Extra Corporal Life Support or Berlin-Heart
  • Patient with congenital cardiopathy with a palliative correction or an incomplete correction
  • Open thorax
  • Prone position
  • Investigators not available
  • No security number registration.
  • Moribund patient

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Ability of the stroke volume variation after abdominal compression to predict fluid responsiveness
Délai: 30 minutes
Stroke volume will be measured before and after a calibrated abdominal compression and after a fluid load. Patient will then be sorted in two groups. Responders defined as patient that show an increase in stroke volume after a 10ml/kg fluid load and Fluid non responders, defined as patient that show an increase of less than 15 % in stroke volume. The ROC curve will investigate the ability of stroke volume variation after abdominal compression to predict fluid responsiveness.
30 minutes

Mesures de résultats secondaires

Mesure des résultats
Délai
Ability of the pulse pressure variation after abdominal compression to predict fluid responsiveness
Délai: 30 minutes
30 minutes
Ability of the heart rate variation after abdominal compression to predict fluid responsiveness
Délai: 30 minutes
30 minutes
Correlation between stroke volume variation, heart rate variation, pulse pressure variation between the abdominal compression and the fluid load
Délai: 30 minutes
30 minutes

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Directeur d'études: Jean-Luc Fellahi, MD, PhD, Hôpital Louis Pradel, Hospice Civil de Lyon

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 juillet 2015

Achèvement primaire (Réel)

1 décembre 2016

Achèvement de l'étude (Réel)

1 décembre 2016

Dates d'inscription aux études

Première soumission

16 juillet 2015

Première soumission répondant aux critères de contrôle qualité

21 juillet 2015

Première publication (Estimation)

22 juillet 2015

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Estimation)

28 décembre 2016

Dernière mise à jour soumise répondant aux critères de contrôle qualité

25 décembre 2016

Dernière vérification

1 décembre 2016

Plus d'information

Termes liés à cette étude

Termes MeSH pertinents supplémentaires

Autres numéros d'identification d'étude

  • EudraCT/ANSM 2015-A00388-41

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner