- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT02540135
Fluorescein vs. iMRI in Resection of Malignant High Grade Glioma
Fluorescein vs. Intraoperative MRI in the Resection of Malignant High Grade Glioma
This study plans to learn more about if fluorescein with intraoperative Magnetic Resonance Imaging (MRI) is as good as intraoperative MRI (iMRI) alone in detecting the presence of tumor tissue during surgery.
Both fluorescein and intraoperative MRI have been studied and routinely used to aid the neurosurgeon in distinguishing normal brain from tumor, helping the neurosurgeon to safely resect more tumor tissue during surgery.
This study will enroll patients with malignant high grade glioma who are going to have a surgery to remove their brain tumor.
For half of the patients, fluorescein and intraoperative MRI will be used together during surgery. For half of the patients, only intraoperative MRI will be used during surgery. iMRI is used as final verification of complete, safe resection in both arms.
Aperçu de l'étude
Statut
Intervention / Traitement
Description détaillée
Extent of surgical resection of malignant high grade glioma has been established as one of the most important predictors of overall survival and six-month progression free survival. Unfortunately, it is often difficult in surgery to distinguish between tumor and normal brain. Various technologies have been developed to help the surgeon more readily safely increase extent of resection in order to achieve an improved survival after glioblastoma resection. Fluorescein has been used at some institutions for a number of years to improve visualization of high-grade gliomas enabling their better resection. Intraoperative MRI has also been developed with similar intent, allowing the patient to be imaged intraoperatively to determine extent of resection and any need for further resection prior to leaving the operating room. While there is some evidence these technologies improve extent of resection in comparison to historical controls, they have never been tested against each other in any prospective fashion.
Intraoperative MRI has significant cost and significantly increases operative time. Fluorescein is a very inexpensive injectable agent and, if as good at achieving gross total resection as intraoperative MRI, would offer patients similar surgical outcomes with less anesthetic time and cost than intraoperative MRI. This study aims to investigate the value of fluorescein or intraoperative MRI in malignant glioma patients' extent of tumor resection in a prospectively randomized manner.
Type d'étude
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
Colorado
-
Aurora, Colorado, États-Unis, 80045
- University of Colorado Anschutz Medical Campus
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Presents with presumed or pathologically proven enhancing primary or secondary high grade glioma for surgical resection
- Eligible for gross total resection of enhancing component of tumor
- Karnofsy performance status >/= 70%
Exclusion Criteria:
- Presence of multi-focal disease
- Disease that crosses the mid-line
- History of adverse reaction to flourescein
- Known ongoing pregnancy
- Inability to grant consent
- Contraindication to perform iMRI
- Contraindication to flourescein
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Autre
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Seul
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Arm A
Flourescein plus intraoperative MRI
|
fluorescein and conventional neuro-navigation
conventional neuro-navigation and iMRI
Autres noms:
|
|
Comparateur actif: Arm B
intraoperative MRI alone
|
conventional neuro-navigation and iMRI
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Extent of resection
Délai: 36 hours
|
This outcome will utilize tumor volumetry of residual enhancing tumor after resection.
|
36 hours
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Surgical time difference
Délai: 36 hours
|
This outcome will evaluate the difference in length of surgery time between each arm.
|
36 hours
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: David R Ormond, MD, University of Colorado, Denver
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Anticipé)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 15-1313
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .