Ankle - Brachial Index Measurement in Atrial Fibrillation (AFABI)
Ankle - Brachial Index Measurement in Patients With Atrial Fibrillation Before and After Electrical Cardioversion
Consecutive patients with atrial fibrillation will be admitted to the hospital for electrical cardioversion. Ankle brachial index will be measured three times with oscillometric method and three times with doppler method. Two study sessions will be performed: the first before and the second after electrical cardioversion. The first session will be ended before anesthesia. The second session will be started before a conscious patient will be transported from intensive care unit to general ward.
All the measurements will be taken in the intensive care unit at an ambient temperature of 21° C, after patients will give their written informed consent to participate in the study. All patients will be awake, fasting and in the supine position. ABI will be measured according to the guidelines issued by AHA. Systolic blood pressure will be measured using a Doppler device (Echo Sounder ES-101EX, Hadeco, Japan) and a validated and calibrated aneroid sphygmomanometer (Minimus II, Rister, Germany). Measurement of ABI using oscillometric method will be performed using WatchBP Office ABI system (Microlife WatchBP AG, Widnau, Switzerland). The appropriate cuff size will be used with the width of the cuff being at least 40% of the limb circumference. The arm with higher systolic blood pressure will be used to calculate the ABI. Higher systolic blood pressure measured on the posterior tibial or dorsalis pedis artery will be used to calculate the ABI. During both study sessions ABI measurements will be repeated 3 times with each method in the reverse order of the preceding measurement e.g., in the case of the initial counterclockwise sequence: right arm, right popliteal, right dorsalis pedis, left popliteal, left dorsalis pedis, left arm, right arm, the clockwise sequence will be used, starting and ending with the left arm. The same sequence of limb pressure measurements will be used used during the study.
A sample size calculation was based on the preliminary observations made by the study team. It was calculated that the study sample size of 79 subjects would be needed to detect a difference of 0.1 in the ABI measured in sinus rhythm and during atrial fibrillation, with a two-tailed α of 0.05 and a (1-β) of 0.90. The investigators initial estimate of sample size of 115 patients incorporated an assumption of dropout due to non-effective electrical cardioversion, patient decision to quit study or failure to obtain adequate ABI.
The measurements will be repeated three times with each method and for the each method the mean will be used for the calculations. Investigator - study nurse, trained at the vascular department, will perform all ABI measurements.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Patients undergoing electrical cardioversion due to atrial fibrillation
Exclusion Criteria:
- Circulatory instability
- Use of vasoconstrictive agents
- Limb trauma
- Upper limb artery stenosis
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Autre: Single arm
Interventions - repeated ankle - brachial index measurement before and after electrical cardioversion in patients with atrial fibrillation
|
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Difference Between ABI (Ankle - Brachial Index) Before Electrical Cardioversion Using Two Methods (Doppler and Oscillometric).
Délai: Through the study
|
3 ABI measurements using both methods (doppler and oscillometric) were performed per participant and the Mean value was considered for each participant, and then a Median value was calculated across participants.
|
Through the study
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Difference Between ABI Measured Before and After Electrical Cardioversion Using Doppler Method.
Délai: Through the study period
|
3 ABI measurements using doppler method were performed per participant and the Mean value was considered for each participant, and then a Median value was calculated across participants
|
Through the study period
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Maciej Sinski, M.D., Ph.D., Medical University of Warsaw
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- AFABI
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .