- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT03341546
Estimating Patient Size From a Single Radiograph (VocMepAdar)
Validation of a Computational Model to Estimate Patient Anterior-posterior Dimension From an Abdominal Radiograph
A computational model has been created to estimate the abdominal depth of a patient from a single x-ray image. The model has been tested using phantoms and found to be accurate; this study aims to test the accuracy of the model with patients and in a clinical setting.
This will be achieved by enrolling patient's who have already been referred for an anterior-posterior abdomen x-ray examination to the trial, taking a physical measurement of their anterior-posterior abdominal depth and then comparing this measured value with a value as estimated using the computational model based on the patient's x-ray image.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
A non-commercial computational model has been developed in-house to estimate the patient's anterior-posterior or lateral depth using the radiographic image and the known exposure factors with which it was undertaken. This model has been tested using single composition phantoms and found to be accurate. If it was found to be accurate for real clinical examinations, this would automate the measurement of patient size and give institutions the estimate of patient size required for local paediatric patient dose audit. In turn, this would provide the national data required to propose national reference values for paediatric x-ray examinations, which would give all institutions an important comparator for their performance. This would lead to optimisation in those sites most requiring it; nationally, paediatric x-ray imaging would improve in time.
This pilot study is necessary to determine if the computational model is accurate enough to be relied upon. Accuracy will be determined by comparing the estimate made by the computational model for each patient with an actual measurement of the patient's anterior-posterior abdomen depth made at the time of the examination.
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
Angus
-
Dundee, Angus, Royaume-Uni, DD1 9SY
- NHS Tayside
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Adult
- Referred to Ninewells Hospital for an anterior-posterior abdomen x-ray examination
Exclusion Criteria:
- Patients unable to give consent
- Patients who have had a contrast injection in the previous 24 hours
- Patients suffering abdominal pain at the time of the examination
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
Patient cohort
20 patients referred to Ninewells Hospital radiology department for an anterior-posterior abdomen x-ray examination.
All of these patients will have a measurement of their anterior-posterior depth before undergoing their x-ray examination.
An estimate of their anterior-posterior depth will then be made from their x-ray image using the computational model.
|
A single measurement of the patient's anterior-posterior abdominal depth
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Accuracy of the Computational Model
Délai: 2 months
|
The computational model was used to estimate the patient's anterior-posterior abdominal depth using the digital radiographic image, the exposure factors with which it was acquired and a priori knowledge relating to the x-ray unit and digital detector. The outcome measure was the accuracy with which the computational model estimates the patient's anterior-posterior abdominal depth. It was determined by comparing the estimate to measured anterior-posterior abdominal depth (measured at the time of the x-ray examination). Results are expressed as a percentage deviation; a low % deviation is more accurate, a high % deviation less accurate. |
2 months
|
Collaborateurs et enquêteurs
Parrainer
Collaborateurs
Les enquêteurs
- Chaise d'étude: Sarah Vinnicombe, MD, University of Dundee
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Autres numéros d'identification d'étude
- 2017RA01
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .