- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT05140447
Temperature Change of the Pulpal Floor and Restoration With Preheated Resin Composite (A Randomized Clinical Trial)
clinical evaluation of the effect of preheating BIS-GMA free resin composite at different temperatures on temperature change of the pulpal floor and restorations and compare it with BIS-GMA containing resin composite.
Hypothesis: Could the preheated composite affect the temperature of the pulpal floor
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Minya, Egypte, 61519
- Faculty of Dentistry - Minia University
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Healthy men and women patients of 25-45 years.
- They should have a good oral hygiene level.
- Presence of at least two posterior class I or II carious lesions to be restored with two different composite resin restorations.
- All carious lesions in selected patients didn't close to the pulp in the preoperative radiograph.
- No preoperative pain.
- Normal occlusal contact with opposing teeth.
- No history of periodontal treatment, including periodontal surgery, in the past year.
- All patients had to sign a written consent before being included.
- A good likelihood of recall availability.
Exclusion Criteria:
- patient with severe periodontitis or severe erosion damage.
- patients with a compromised medical history or had received therapeutic irradiation to the head and neck region.
- If analgesics or antibiotics had administered by the patient during the past 12 hours preoperatively as it might alter their pain perception.
- patients reported bruxism or clenching.
- Greater than grade I mobility or pocket depth greater than 5mm.
- Non-restorable teeth or hopeless teeth.
- Immature teeth.
- Radiographic evidence of external or internal root resorption.
- Alcoholic and smoker patients.
- Pregnant or breastfeeding ladies.
- Patients who had physical disabilities, or who are unable to brush their teeth.
- Individuals who had sensitive teeth but with one of the following conditions was excluded from the study, teeth with large restoration, abutment of teeth of removable partial dentures, dental restorations, abutment of teeth of removable partial dentures, enamel cracks, leakage of fillings or other restorations teeth, dental pulp lesions, dental abscesses, pulpitis, and atypical facial pain.
- Patients who had non-carious lesions like attrition, erosion, abrasion or abfraction.
- Patients had participated in a clinical trial within 6 months before commencement of this trial.
- Patients unable to return for a recall appointment.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Autre
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Comparateur actif: Admira 50º C
in this subgroup the patient's teeth was restored with Admira fusion extra resin composite preheated to 50º C
|
evaluate the effect of preheating BIS-GMA free resin composite at different temperatures on temperature change of the pulpal floor and restorations and compare it with BIS-GMA containing resin composite.
Autres noms:
|
|
Comparateur actif: Admira 70º C
in this subgroup the patient's teeth was restored with Admira fusion extra resin composite preheated to 70º C
|
evaluate the effect of preheating BIS-GMA free resin composite at different temperatures on temperature change of the pulpal floor and restorations and compare it with BIS-GMA containing resin composite.
Autres noms:
|
|
Comparateur actif: Viscalor 50º C
in this subgroup the patient's teeth was restored with Viscalor resin composite preheated to 50º C
|
evaluate the effect of preheating BIS-GMA free resin composite at different temperatures on temperature change of the pulpal floor and restorations and compare it with BIS-GMA containing resin composite.
Autres noms:
|
|
Comparateur actif: Viscalor 70º C
in this subgroup the patient's teeth was restored with Viscalor resin composite preheated to 70º C
|
evaluate the effect of preheating BIS-GMA free resin composite at different temperatures on temperature change of the pulpal floor and restorations and compare it with BIS-GMA containing resin composite.
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
pulpal floor temperature and restoration temperature
Délai: one year
|
evaluation the effect of preheating BIS GMA free resin composite at different temperature on temperature change of pulpal floor and restoration and compare it with BIS GMA containing resin composite All readings were taken with the presence of a rubber dam and recorded in Celsius (°C). Five temperature readings were measured for each tooth; (C0): pulpal floor temperature before beginning the restorative procedure. (C1): pulpal floor temperature during placement of preheated composite. (C2): top composite surface after packing and before curing. (C3): pulpal floor temperature after curing of the preheated composite. (C4): top composite surface after curing. The pulpal floor and the restoration temperature of each tooth was measured by a K-type temperature Probe attached to portable mini type thermometer device |
one year
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
The effect of different preheating temperatures on restoration temperature and pulpal floor temperature
Délai: one year
|
Five temperature readings were measured for each tooth; (C0): pulpal floor temperature before beginning the restorative procedure.
(C1): pulpal floor temperature during placement of preheated composite.
(C2): top composite surface after packing and before curing.
(C3): pulpal floor temperature after curing of the preheated composite.
(C4): top composite surface after curing.
The pulpal floor and the restoration temperature of each tooth was measured by a K-type temperature Probe attached to portable mini type thermometer device
|
one year
|
Autres mesures de résultats
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
The difference in restoration and pulpal floor temperatures before and after curing of preheated resin composite
Délai: one year
|
Five temperature readings were measured for each tooth; (C0): pulpal floor temperature before beginning the restorative procedure.
(C1): pulpal floor temperature during placement of preheated composite.
(C2): top composite surface after packing and before curing.
(C3): pulpal floor temperature after curing of the preheated composite.
(C4): top composite surface after curing.
The pulpal floor and the restoration temperature of each tooth was measured by a K-type temperature Probe attached to portable mini type thermometer device
|
one year
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Directeur d'études: Mona I Riad, Professor, Professor at Faculty of Dentistry Cairo University
- Directeur d'études: Nermin A Mahmoud, Lecturer, Lecturer at Faculty of Dentistry Minia University
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- 490
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .