Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Hyperpolarized MR Imaging With Carbon-13 Pyruvate in the Human Body (POLARIC-13)

12 novembre 2026 mis à jour par: National Heart Centre Singapore

Positron emission tomography with 18F fluorodeoxyglucose (FDG) is the conventional imaging technique to provide information regarding tissue glucose uptake and has been highly clinically successful. However, it cannot assess downstream metabolism, which may be useful in the diagnosis and assessment of treatment response in a variety of diseases. Patients will also be exposed to ionizing radiation, the amount of exposure can vary depending on the dose of tracer administered, frequency of scans and duration of each scan. Carbon-13 (13C) magnetic resonance imaging (MRI) is particularly attractive for metabolic imaging because carbon serves as the backbone of nearly all organic molecules in the body. With this technique, the polarization increases to approximately 30%-40%, an increase of over 10,000 to 100,000-fold, thereby dramatically increasing the MRI signal . Whilst the role of 13C imaging has been demonstrated in many sites around the world, we aim to demonstrate the feasibility and application of 13C hyperpolarized imaging in healthy Singapore residents and patients with cardiovascular and/or cardiometabolic diseases.

Aperçu de l'étude

Description détaillée

Positron emission tomography with 18F fluorodeoxyglucose (FDG) is the conventional imaging technique to provide information regarding tissue glucose uptake and has been highly clinically successful. However, it cannot assess downstream metabolism, which may be useful in the diagnosis and assessment of treatment response in a variety of diseases. Patients will also be exposed to ionizing radiation, the amount of exposure can vary depending on the dose of tracer administered, frequency of scans and duration of each scan.

Carbon 13 (13C) magnetic resonance imaging (MRI) is particularly attractive for metabolic imaging because carbon serves as the backbone of nearly all organic molecules in the body. However, the low natural abundance of the 13C isotope at ~1.1% has made in vivo imaging extremely challenging. To improve the MR signal 13C nuclei, probes are synthetically enriched to increase the concentration of the 13C label in a molecule. MRI signal can be further increased by the process of hyperpolarization. At low temperature and high magnetic field, electrons have a very high level of polarization (ie, nearly all the electrons are aligned in the same direction). This high level of polarization can be transferred to 13C-labeled probes, increasing their MRI signals. This transfer of polarization is accomplished by mixing radicals (a source of free electrons) with the 13C-labeled probe(s) to be hyperpolarized and placing the mixture in a polarizer at a magnetic field typically of 3.0-5.0 T and at a low temperature (approximately 1 K). Microwave irradiation is then applied to transfer the polarization from unpaired electrons in a trityl radical to the 13C-labeled probe. The final solution retains a high level of polarization and can be formulated to be at physiologic pH, osmolarity, and temperature for in vivo injection and metabolic investigations.

With this technique, the polarization increases to approximately 30%-40%, an increase of over 10,000 to 100,000-fold, thereby dramatically increasing the MRI signal (Figure 1). The enhanced signal, however, is typically available only for a short period of time (1-2 minutes), as the polarization decays back to its thermal equilibrium level. Therefore, rapid imaging is needed to acquire high signal-to-noise ratio metabolic data with minimal polarization loss and to measure fast metabolic processes.

To date, hyperpolarized imaging technique has been performed in more than 800 healthy volunteers and patients; and in more than 1,200 studies in various clinical conditions.

HYPOTHESIS AND OBJECTIVES:

This proof-of-concept study to demonstrate feasibility and application of 13C hyperpolarized imaging in healthy Singapore residents and patients with cardiovascular/cardiometabolic diseases.

  1. To establish reference ranges in the metabolic products of hyperpolarized 13C-pyruvate (lactate, alanine and bicarbonate) in healthy volunteers and examine repeatability of the 13C hyperpolarized imaging sequences.
  2. To develop the application of 13C hyperpolarized imaging in patients with cardiovascular and cardiometabolic diseases.

Type d'étude

Interventionnel

Inscription (Estimé)

200

Phase

  • Phase 2

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

  • Nom: Calvin WL Chin
  • Numéro de téléphone: 6568449055
  • E-mail: CAMI@nhcs.com.sg

Lieux d'étude

      • Singapore, Singapour, 169609
        • Recrutement
        • National Heart Centre Singapore

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

21 ans à 99 ans (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Oui

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

Healthy Volunteers:

  1. Age 21 years and above
  2. No significant medical co-morbidities (such as chronic kidney disease, diabetes mellitus, heart failure, ischemic heart disease, previous strokes)
  3. No history of cancer
  4. Able and willing to comply with study procedures and provide signed informed consent

Patients with cardiovascular/cardiometabolic diseases:

  1. Age 21 years and above
  2. Physician diagnosed cardiovascular conditions: ischemic heart disease, inherited cardiomyopathies (hypertrophic, dilated or infiltrative cardiomyopathies) and stable heart failure; and/or
  3. Cardiometabolic conditions (such as diabetes on medications, hypertension, central obesity, fatty liver disease)
  4. Able and willing to comply with study procedures and provide signed informed consent

Exclusion Criteria:

  1. Standard contraindications for magnetic resonance procedures (such as implantable medical devices, suspected presence of surgical apparatus or shrapnel, severe claustrophobia)
  2. Unstable medical conditions (such as symptomatic heart failure, unstable hypertension/glucose levels as determined by investigators, symptomatic arrhythmias, angina)
  3. Pregnant or nursing women
  4. Known allergies to pyruvate or any of its components

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Diagnostique
  • Répartition: N / A
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Hyperpolarized Pyruvate [13C] Injection

Hyperpolarized 13C-pyruvate is injected intravenously at a dose of 0.43 mL/kg body weight, and at a rate of 5 mL/second followed by a 20 mL saline flush at 5 mL/second when the patient is already in the MRI scanner.

Hyperpolarized 13C-pyruvate is injected intravenously at a dose of 0.43 mL/kg body weight, and at a rate of 5 mL/second followed by a 20 mL saline flush at 5 mL/second when the patient is already in the MRI scanner

Autres noms:
  • Pyruvate de carbone C 13 hyperpolarisé
  • (13C) pyruvate

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Feasibility and reproducibility of Imaging Technique
Délai: 30 - 45 minutes post dose

Feasibility and reproducibility of the imaging technique in healthy volunteers and patients with cardiovascular and/or cardiometabolic diseases

30 - 45 minutes post dose

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

17 octobre 2024

Achèvement primaire (Estimé)

31 mai 2028

Achèvement de l'étude (Estimé)

31 mai 2028

Dates d'inscription aux études

Première soumission

2 octobre 2024

Première soumission répondant aux critères de contrôle qualité

15 octobre 2024

Première publication (Réel)

17 octobre 2024

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

17 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

12 novembre 2026

Dernière vérification

1 novembre 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner