Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Intraoperative Analysis of Knee Kinematics During ACL Reconstruction - an Exploratory Study (CINEGEN)

Reconstruction of anterior cruciate ligament (ACL) is a common procedure in orthopaedic surgery, aimed at restoring stability to your knee. This procedure involves performing an anterior cruciate ligament (ACL) graft and an anterolateral ligament (ALL) graft.

Despite technological advances and improvements in surgical techniques, failure rates remain high. In this context, a better understanding of knee movements (the position of the femur and tibia, as well as the ligaments) during flexion whilst reconstructing your ACL could improve the precision of reconstructions and reduce the long-term failure rate.

Using a surgical navigation system, it is possible to record data on the positioning of the femur and tibia during flexion and extension. This type of morpho-functional analysis of knee kinematics during ACL reconstruction has never been carried out before.

Aperçu de l'étude

Statut

Pas encore de recrutement

Intervention / Traitement

Description détaillée

Anterior cruciate ligament reconstruction is a common procedure in orthopaedic surgery, aimed at restoring knee stability following a ligament rupture. Despite technological advances and improvements in surgical techniques, failure rates remain a cause for concern.

There are many causes of ligament reconstruction failure, including biological factors (e.g. poor graft integration), repeated trauma and technical errors. Among the latter, poor tunnel positioning is the main cause, accounting for up to 29% of errors, the majority of which (75%) involve the femoral tunnel. Biomechanical studies have confirmed that inadequate positioning of the femoral tunnel alters knee kinematics, increasing stress on the graft and predisposing it to secondary rupture. In this context, a better understanding of intra-articular knee movements and the tension/relaxation profiles of the knee ligaments during flexion movements in surgery could improve the accuracy of reconstructions and reduce the long-term failure rate.

Using a surgical navigation system, it is possible to record data on the dynamic positioning of the femur and tibia during flexion and extension. MRI imaging also makes it possible to generate a digital twin of the patient's knee, including the patient's ligaments and their bony attachments. Aligning this digital twin with the positions of the femur and tibia recorded using intraoperative navigation makes it possible to determine, at different angles of flexion, the position of the digital twin and thus to measure the distance between the ligament insertions in the knee. This type of morpho-functional analysis of the 3D kinematics of the knee has not been published. This is why this research is initiated.

Type d'étude

Interventionnel

Inscription (Estimé)

30

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Lieux d'étude

      • Lyon, France, 69008
        • Hôpital privé Jean Mermoz
        • Contact:

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte

Accepte les volontaires sains

Non

La description

Inclusion Criteria:

  • Patient, male or female, aged between 18 and 40
  • Patient eligible for ACL and LAL reconstruction
  • Patient who is member of or covered by a social security scheme
  • Patient who speaks French and has signed an informed consent form

Exclusion Criteria:

  • Patient with a contraindication to MRI
  • Patient with osteoarthritis of the joint
  • Patient with a BMI > 30
  • Patient with history of trauma or previous knee surgery
  • Patient with knee trauma other than a sprain
  • Patient under legal guardianship: an adult under guardianship, curatorship or other legal protection, or deprived of liberty by judicial or administrative order
  • Pregnant or breastfeeding woman

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Science basique
  • Répartition: N / A
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Knee cinematics
Intraoperative morpho-functional analysis of the injured knee
The pins used for ACL reconstruction will serve as a mount for the optical markers used to record the position data of the femur and tibia during ACL reconstruction.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Knee cinematics
Délai: Day 0

The kinematic changes in the knee resulting from ACL reconstruction in flexion (at 90° and 45°) and in extension will be assessed intraoperatively, based on the following distances measured before and after placement of the ACL graft:

  • Femoro-tibial distance for the insertion of the LLE
  • Femoro-tibial distance for the insertion of the LLI
  • Femoro-tibial distance for the insertion of the ACL (before graft placement)
  • Distance between the centres of the intra-articular openings of the femoral and tibial tunnels (after graft placement)
  • Femoro-tibial distance for the insertion of the PCL
Day 0

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

1 juillet 2027

Achèvement primaire (Estimé)

1 mars 2028

Achèvement de l'étude (Estimé)

1 mars 2028

Dates d'inscription aux études

Première soumission

13 juin 2026

Première soumission répondant aux critères de contrôle qualité

13 juin 2026

Première publication (Réel)

18 juin 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

18 juin 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

13 juin 2026

Dernière vérification

1 juin 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • 2026-A00868-43

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner