Ezt az oldalt automatikusan lefordították, és a fordítás pontossága nem garantált. Kérjük, olvassa el a angol verzió forrásszöveghez.

Comparison of Three Airway Intubation Devices for First-Attempt Success in General Anesthesia Patients

2026. szeptember 5. frissítette: Fu Jiacheng, Guangzhou University of Chinese Medicine

Application of SPHJ-II, Visual Lighted Stylet, and Visual Intubation Fiberscope in Endotracheal Intubation in Patients Under General Anesthesia

The goal of this clinical trial is to compare three airway intubation devices in adult patients undergoing general anesthesia who require tracheal intubation. The main questions it aims to answer are:

  • Does the SPHJ-II video-assisted adjustable red-light fluoroscopic tracheal intubation scope improve first-attempt intubation success compared with a visual lighted stylet and a visual intubation fiberscope?
  • How do the three devices compare in intubation efficiency, intubation-related complications, and peri-intubation physiological responses?

Researchers will compare the SPHJ-II, the visual lighted stylet, and the visual intubation fiberscope to evaluate their performance during tracheal intubation.

Participants will be randomly assigned to one of the three device groups and undergo tracheal intubation during general anesthesia using the assigned device.

A tanulmány áttekintése

Részletes leírás

Tracheal intubation is an essential procedure for airway management during general anesthesia. Several visualized intubation devices are used in clinical practice, but each has different advantages and limitations in visualization, maneuverability, and ease of endotracheal tube placement. The SPHJ-II is a novel video-assisted adjustable red-light fluoroscopic tracheal intubation scope designed to improve visualization and facilitate intubation.

This study is a prospective, randomized, single-center, single-blind, parallel-group clinical trial designed to compare the clinical performance of the SPHJ-II, a visual lighted stylet, and a visual intubation fiberscope in adult patients undergoing general anesthesia requiring tracheal intubation. Participants will be randomly assigned in a 1:1:1 ratio to one of the three device groups. All tracheal intubations will be performed by experienced anesthesiologists using standardized operating procedures. The study is designed to evaluate whether the SPHJ-II provides advantages in first-attempt intubation success and procedural performance compared with the other two commonly used visualized intubation devices.

Tanulmány típusa

Beavatkozó

Beiratkozás (Becsült)

549

Fázis

  • Nem alkalmazható

Kapcsolatok és helyek

Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.

Tanulmányi kapcsolat

Tanulmányi helyek

    • Guangdong
      • Guangzhou, Guangdong, Kína, 510405
        • Toborzás
        • The First Affiliated Hospital of Guangzhou University of Chinese Medicine
        • Kapcsolatba lépni:
        • Kutatásvezető:
          • Jiacheng Fu, MD

Részvételi kritériumok

A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.

Jogosultsági kritériumok

Tanulmányozható életkorok

  • Felnőtt
  • Idősebb felnőtt

Egészséges önkénteseket fogad

Nem

Leírás

Inclusion Criteria:

  • Age 18 to 65 years, inclusive. American Society of Anesthesiologists (ASA) physical status I to III. Scheduled for surgery under general anesthesia requiring endotracheal intubation.

The participant or legally authorized representative is fully informed of the purpose, methods, potential risks, and possible benefits of the study and provides written informed consent.

Exclusion Criteria:

  • Anticipated severe difficulty with mask ventilation, such as severe obesity (BMI > 35 kg/m²) with obstructive sleep apnea syndrome, history of neck radiotherapy, craniofacial malformation, or other conditions judged by the attending anesthesiologist to confer high risk for mask ventilation, and patients requiring awake tracheal intubation.

Cervical spine instability, cervical trauma, rheumatoid arthritis involving the cervical spine, ankylosing spondylitis, or any condition requiring absolute cervical immobilization during the procedure.

Significant airway involvement identified preoperatively, including imaging evidence of tracheal narrowing with minimal diameter < 5 mm, severe tracheal compression, displacement or collapse, stridor at rest or after activity, vocal cord paralysis with dyspnea, giant thyroid mass with orthopnea, or other oral, pharyngeal, or laryngeal tumor, edema, stenosis, abscess, or severe upper airway anatomical abnormality affecting glottic exposure or endotracheal tube passage.

High risk of reflux and aspiration. Severe cardiovascular disease, severe respiratory disease, severe hepatic or renal dysfunction, severe coagulation disorder, frailty, pregnancy or breastfeeding, or known allergy.

Any other condition making the patient unsuitable for participation in the study, such as psychiatric illness, communication disorder, or poor compliance.

Tanulási terv

Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.

Hogyan készül a tanulmány?

Tervezési részletek

  • Elsődleges cél: Kezelés
  • Kiosztás: Véletlenszerűsített
  • Beavatkozó modell: Párhuzamos hozzárendelés
  • Maszkolás: Kettős

Fegyverek és beavatkozások

Résztvevő csoport / kar
Beavatkozás / kezelés
Kísérleti: SPHJ-II group
Participants randomized to this arm will undergo tracheal intubation using the SPHJ-II visual adjustable red-light tracheal intubation device after induction of general anesthesia.
The SPHJ-II is a visual adjustable red-light tracheal intubation device used to facilitate endotracheal intubation after induction of general anesthesia.
Aktív összehasonlító: Video lighted stylet group
Participants randomized to this arm will undergo tracheal intubation using a video lighted stylet after induction of general anesthesia.
A video lighted stylet used to facilitate endotracheal intubation after induction of general anesthesia.
Aktív összehasonlító: Visual intubation fiberscope group
Participants randomized to this arm will undergo tracheal intubation using a visual intubation fiberscope after induction of general anesthesia.
A visual intubation fiberscope used to facilitate endotracheal intubation after induction of general anesthesia.

Mit mér a tanulmány?

Elsődleges eredményintézkedések

Eredménymérő
Intézkedés leírása
Időkeret
First-attempt intubation success rate
Időkeret: During the intubation procedure
First-attempt intubation success is defined as successful tracheal intubation using the randomly assigned study device on the first attempt, with successful placement confirmed by the appearance of a sustained and regular end-tidal carbon dioxide waveform within 60 seconds of intubation attempt initiation.
During the intubation procedure

Másodlagos eredményintézkedések

Eredménymérő
Intézkedés leírása
Időkeret
Intubation time
Időkeret: During the intubation procedure
Intubation time is defined as the time from first insertion of the assigned intubation device into the oral cavity until successful tracheal intubation is confirmed by at least 3 consecutive end-tidal carbon dioxide waveforms.
During the intubation procedure
Number of intubation attempts
Időkeret: During the intubation procedure
Total number of attempts required to achieve successful tracheal intubation.
During the intubation procedure
Incidence of hypoxemia
Időkeret: During the intubation procedure
Occurrence of oxygen desaturation during tracheal intubation according to the study safety criteria.
During the intubation procedure
Incidence of airway-related complications
Időkeret: During and immediately after the intubation procedure
Occurrence of airway-related complications during or immediately after intubation, including oral or pharyngeal mucosal injury, bleeding, and dental injury.
During and immediately after the intubation procedure
Peri-intubation heart rate
Időkeret: From baseline before induction to 2 minutes after successful tracheal intubation
Heart rate (HR) measured at predefined peri-intubation time points: baseline after approximately 10 minutes in the operating room before induction (T0), 2 minutes before intubation after induction (T1), within 1 minute after successful tracheal intubation (T2), and 2 minutes after successful tracheal intubation (T3).
From baseline before induction to 2 minutes after successful tracheal intubation
Peri-intubation oxygen saturation
Időkeret: From baseline before induction to 2 minutes after successful tracheal intubation
Peripheral oxygen saturation (SpO₂) measured at predefined peri-intubation time points: baseline after approximately 10 minutes in the operating room before induction (T0), 2 minutes before intubation after induction (T1), within 1 minute after successful tracheal intubation (T2), and 2 minutes after successful tracheal intubation (T3).
From baseline before induction to 2 minutes after successful tracheal intubation
Peri-intubation systolic blood pressure
Időkeret: From baseline before induction to 2 minutes after successful tracheal intubation
Systolic blood pressure (SBP) measured at predefined peri-intubation time points: baseline after approximately 10 minutes in the operating room before induction (T0), 2 minutes before intubation after induction (T1), within 1 minute after successful tracheal intubation (T2), and 2 minutes after successful tracheal intubation (T3).
From baseline before induction to 2 minutes after successful tracheal intubation
Peri-intubation diastolic blood pressure
Időkeret: From baseline before induction to 2 minutes after successful tracheal intubation
Diastolic blood pressure (DBP) measured at predefined peri-intubation time points: baseline after approximately 10 minutes in the operating room before induction (T0), 2 minutes before intubation after induction (T1), within 1 minute after successful tracheal intubation (T2), and 2 minutes after successful tracheal intubation (T3).
From baseline before induction to 2 minutes after successful tracheal intubation

Együttműködők és nyomozók

Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.

Nyomozók

  • Kutatásvezető: Wuhua Ma, MD, The First Affiliated Hospital, Guangzhou University of Traditional Chinese Medicine

Tanulmányi rekorddátumok

Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.

Tanulmány főbb dátumok

Tanulmány kezdete (Tényleges)

2026. július 10.

Elsődleges befejezés (Becsült)

2026. október 31.

A tanulmány befejezése (Becsült)

2026. december 31.

Tanulmányi regisztráció dátumai

Először benyújtva

2026. június 30.

Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak

2026. július 8.

Első közzététel (Tényleges)

2026. július 13.

Tanulmányi rekordok frissítései

Utolsó frissítés közzétéve (Tényleges)

2026. szeptember 9.

Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak

2026. szeptember 5.

Utolsó ellenőrzés

2026. szeptember 1.

Több információ

A tanulmányhoz kapcsolódó kifejezések

Egyéb vizsgálati azonosító számok

  • GZUCM1-2026-06
  • K-2025-214 (Egyéb azonosító: Ethics Committee of the First Affiliated Hospital of Guangzhou University of Chinese Medicine)

Terv az egyéni résztvevői adatokhoz (IPD)

Tervezi megosztani az egyéni résztvevői adatokat (IPD)?

NEM

IPD terv leírása

Individual participant data will not be shared because the study involves patient-level clinical data and no formal data-sharing plan has been established.

Gyógyszer- és eszközinformációk, tanulmányi dokumentumok

Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz

Nem

Egy amerikai FDA által szabályozott eszközterméket tanulmányoz

Nem

Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .

Iratkozz fel