Rotational Stability of the Acunex Vario Toric

2026. november 3. frissítette: Prim. Prof. Dr. Oliver Findl, MBA

Evaluation of the Rotational Stability of the Acunex Vario Toric Intraocular Lens

Efficacy of the rotational stability and astigmatism correction of a toric EDOF IOL, the Acunex Vario toric.

A tanulmány áttekintése

Állapot

Toborzás

Körülmények

Beavatkozás / kezelés

Részletes leírás

Recent advances in cataract surgery technology have transformed the procedure from a purely vision-restoring approach into a procedure for correcting presbyopia. Patients' resulting higher expectations regarding freedom from spectacles have led to advances in intraocular lens (IOL) technology in recent years. The implantation of a standard monofocal IOL designed to achieve emmetropia results in a high level of patient satisfaction with regard to distance vision. However, spectacles are still required for intermediate and near vision.

One approach to achieving freedom from spectacles at all distances is the use of multifocal IOLs. Compared with monofocal IOLs, however, these lenses are more frequently associated with photic phenomena such as glare and halos, as well as reduced contrast sensitivity. Another approach to minimize the need for spectacles is the use of IOLs with extended depth of focus (EDOF). These lenses feature an extended distance focus range that extends into the intermediate range, thereby offering high visual quality across a continuous focus range. Unlike trifocal IOLs, which split the light into different focal points, the extended focus of these IOLs is designed to improve contrast perception in the intermediate range and reduce light-related phenomena.

Furthermore, residual corneal astigmatism is an important factor in achieving post-operative freedom from spectacles, and its correction is necessary to achieve the best possible visual performance. The most widely used and effective approach to correcting corneal astigmatism is the implantation of a toric IOL. To ensure that these lenses achieve the desired effect, they must be positioned precisely along the intended axis, as any rotation of a toric IOL can reduce its ability to correct astigmatism.

Particularly in the case of IOLs designed to correct presbyopia, such as trifocal or EDOF lenses, it is therefore important to correct corneal astigmatism in order to achieve the best possible post-operative visual outcome. The aim of this study is therefore to analyze the efficacy and rotational stability of a toric EDOF IOL (Acunex Vario toric, AN6VT).

38 eyes from 38 patients will be included into the study, into each eye an AN6VT IOL will be implanted. Follow-up examinations will take place 1 hour, 1 week after surgery on the first eye and 1 week after surgery on the second eye, and 4-6 months post-operatively.

Tanulmány típusa

Beavatkozó

Beiratkozás (Becsült)

38

Fázis

  • Nem alkalmazható

Kapcsolatok és helyek

Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.

Tanulmányi kapcsolat

  • Név: Johannes Zeilinger, MD
  • Telefonszám: 57564 +43 1 91021
  • E-mail: office@viros.at

Tanulmányozza a kapcsolattartók biztonsági mentését

  • Név: Oliver Findl, Prim. Prof. Dr.
  • Telefonszám: 57564 +43 1 91021
  • E-mail: office@viros.at

Tanulmányi helyek

      • Vienna, Ausztria, 1140
        • Toborzás
        • Vienna Institute for Research in Ocular Surgery
        • Kapcsolatba lépni:
          • Johannes Zeilinger, MD
          • Telefonszám: 57564 +43 1 91021
          • E-mail: office@viros.at
        • Kapcsolatba lépni:
          • Oliver Findl, Prim. Prof. Dr.
          • Telefonszám: 57564 +43 1 91021
          • E-mail: office@viros.at

Részvételi kritériumok

A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.

Jogosultsági kritériumok

Tanulmányozható életkorok

21 év (Felnőtt, Idősebb felnőtt)

Egészséges önkénteseket fogad

Nem

Tanulmányozható nemek

Összes

Leírás

Inclusion Criteria:

  • Bilateral age-related cataract scheduled for cataract surgery
  • Age 21 or older
  • Predefined postoperative residual astigmatism to be < 0.5 D (calculated with Barrett total K toric calculator)
  • Calculated IOL power within the range of the investigated IOL
  • Pupil size ≥ 5 mm (in mydriasis)
  • Willingness to comply with the postoperative follow-up examination schedule
  • Written informed consent prior to surgery

Exclusion Criteria:

  • Previous ocular surgery or trauma
  • Extreme shallow anterior chamber
  • Uncontrolled systemic or ocular disease
  • Associated corneal pathologies (e.g., edema, scarring) or relevant other ophthalmic diseases that may result in altered visual outcome or lens stability (e.g., pseudoexfoliation syndrome, floppy iris syndrome, glaucoma, retinal disease)
  • Concurrent participation in another clinical investigation
  • Pregnancy or lactation (pregnancy test will be performed in women of reproductive age)

Tanulási terv

Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.

Hogyan készül a tanulmány?

Tervezési részletek

  • Elsődleges cél: Kezelés
  • Kiosztás: N/A
  • Beavatkozó modell: Egyetlen csoportos hozzárendelés
  • Maszkolás: Nincs (Open Label)

Fegyverek és beavatkozások

Résztvevő csoport / kar
Beavatkozás / kezelés
Kísérleti: Acunex Vario toric

Patient will recieve the Acunex Vario IOL during cataract surgery

The Acunex Vario toric IOL, toric EDOF IOL, will be implanted

Mit mér a tanulmány?

Elsődleges eredményintézkedések

Eredménymérő
Intézkedés leírása
Időkeret
IOL axis rotation
Időkeret: 12 monthes

The IOL axis rotation before and after cataract surgery will be analyzed with retroillumination photographs

12 monthes

Másodlagos eredményintézkedések

Eredménymérő
Intézkedés leírása
Időkeret
Distance visual acuity
Időkeret: 12 months

Uncorrected and corrected distance visual acuity before and after cataract surgery will be determined using ETDRS-charts in a distance of 4 metres

12 months
Intermediate visual acuity
Időkeret: 12 months

Uncorrected and corrected intermediate visual acuity before and after cataract surgery will be determined using ETDRS-charts in a distance of 66 centimetres

12 months
Refraction
Időkeret: 12 months

Refraction before and after cataract surgery will be determined using trial frame glasses and Jackson cross cylinders

12 months

Együttműködők és nyomozók

Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.

Nyomozók

  • Kutatásvezető: Oliver Findl, Prim. Prof. Dr., Vienna Institute for Research in Ocular Surgery

Tanulmányi rekorddátumok

Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.

Tanulmány főbb dátumok

Tanulmány kezdete (Tényleges)

2026. március 27.

Elsődleges befejezés (Becsült)

2027. december 1.

A tanulmány befejezése (Becsült)

2028. július 1.

Tanulmányi regisztráció dátumai

Először benyújtva

2026. november 3.

Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak

2026. november 3.

Első közzététel (Tényleges)

2026. november 9.

Tanulmányi rekordok frissítései

Utolsó frissítés közzétéve (Tényleges)

2026. november 9.

Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak

2026. november 3.

Utolsó ellenőrzés

2026. november 1.

Több információ

A tanulmányhoz kapcsolódó kifejezések

További vonatkozó MeSH feltételek

Egyéb vizsgálati azonosító számok

  • Acunex Vario toric

Terv az egyéni résztvevői adatokhoz (IPD)

Tervezi megosztani az egyéni résztvevői adatokat (IPD)?

ELDÖNTETLEN

Gyógyszer- és eszközinformációk, tanulmányi dokumentumok

Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz

Nem

Egy amerikai FDA által szabályozott eszközterméket tanulmányoz

Nem

Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .