The Effect of Varying Brightness on Palpebral Aperture
The Effect of Varying Brightness Levels on Palpebral Aperture and the Point of Orbicularis Engagement Using EEG Signalling.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Our study will aim to establish the point of orbicularis engagement based on luminous intensity Murray et al. created an Ocular Stress Monitor to see if the contracture of the muscles on the eyelid indicative of pain as a light source was increased in luminosity 8 Our study will go one step further by using video technology and a portable EEG machine to detect the pulses of lid contracture as luminosity of a ring light i s increased incrementally. An advanced calibrated datalogging LED light meter will simultaneously record the level of brightness to establish at which point the spike in EEG occurs. Screenshots from the video recording will be taken and accurate MRD1 measurements can be taken at the point of orbicular i s engagement.
The scientific justification for this research question is twofold We wish to establish the threshold at which orbicularis engages such that palpebral aperture and MRD measurements are altered. This is relevant to the technique of taking these measurements in the clinical environment and the light intensity at which these measurements are taken. We wish to establish the light intensity which should not be exceeded to take these measurements. As photography becomes increasingly used in oculoplastic s clinics we envisage palpebral aperture and MRD1 measurements being performed digitally rather than manually These measurements are relevant to pre operative and post operative imaging, and surgical planning. Furthermore, our results maybe applicable more widely to industry, for example vehicle headlights, bicycle lights, camera flash, workplace lighting.
Reference: Murray I, Plainis S, Carden D. The ocular stress monitor: a new device for measuring discomfort glare. Lighting Research Technology. 2002;34(3):231 239.
Tipo di studio
Iscrizione (Anticipato)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
London, Regno Unito, NW3 2QY
- Ophthalmology, Royal Free Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Aged between 18 and 65 years of age
- A member of the Royal Free NHS trust
Exclusion Criteria:
- No known ocular pathology
- No lid problems/ptosis or previous lid surgery
- No contact lenses in for duration of experiment
- No pseudophakia
- No neurological disease
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Scienza basilare
- Assegnazione: Non randomizzato
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: The observation of eyelid positioning and EEG pulses from the eyelid on increasing brightness
In a dimly lit room the participant will place their chin on the slit lamp We will use t he optimal background illumination used for Humphrey and Goldman visual fields which is 31.5 apostilbs (10Lux 9 They will look into the video camera placed 50cm away, which will have a dimmable remote control ring light fitted around it.
The part icipant will have a reference measure taped to the headrest and three electrodes placed around the right eye.
One active electrode place on the lower lid and one reference electrode towards the temporal margin and one earth electrode placed on the forehead The brightness of the ring light will be increased via the dimmer switch whilst simultaneously recording the lux with the LED light meter.
The participant will be advised t o close their eyes if the brightness becomes uncomfortable and this will be repea ted three times.
|
Up to 30 seconds, three times, looking into a video camera as glare is incrementally increased.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
The point at which the eyelid begins to contract under what brightness level
Lasso di tempo: All carried out within a 2 week period
|
Using a light meter, ring light, and EEG machine
|
All carried out within a 2 week period
|
Collaboratori e investigatori
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Anticipato)
Completamento dello studio (Anticipato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 1062/RD
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Descrizione del piano IPD
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .