Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Intraoperative Driving Pressure and Postoperative Lung Ultrasound Score in Robot-Assisted Radical Prostatectomy

9 giugno 2026 aggiornato da: Fehmi Güralp Güray, Ankara Etlik City Hospital

Evaluation of the Relationship Between Intraoperative Driving Pressure and Postoperative Lung Ultrasound Score in Patients Undergoing Robot-Assisted Laparoscopic Radical Prostatectomy

The primary objective of this study is to evaluate the relationship between intraoperative driving pressure and postoperative lung ultrasound scores in patients undergoing robot-assisted laparoscopic radical prostatectomy. During this specific surgery, factors such as pneumoperitoneum and patient positioning can significantly affect respiratory mechanics. Postoperative lung condition will be objectively assessed using the lung ultrasound score (LUS). The findings may provide valuable insights for optimizing intraoperative mechanical ventilation strategies.

Panoramica dello studio

Descrizione dettagliata

The primary objective of this study is to evaluate the relationship between intraoperative driving pressure and postoperative lung ultrasound scores in patients undergoing robot-assisted laparoscopic radical prostatectomy. During this specific surgery, factors such as pneumoperitoneum and patient positioning can significantly affect respiratory mechanics. By monitoring mechanical ventilation parameters, specifically driving pressure, this study aims to investigate its potential correlation with postoperative lung aeration changes. Postoperative lung condition will be objectively assessed using the lung ultrasound score (LUS). The findings may provide valuable insights for optimizing intraoperative mechanical ventilation strategies.

Tipo di studio

Osservativo

Iscrizione (Stimato)

76

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Backup dei contatti dello studio

Luoghi di studio

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto
  • Adulto più anziano

Accetta volontari sani

No

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

Adult male patients scheduled for elective robot-assisted laparoscopic radical prostatectomy at Etlik City Hospital.

Descrizione

Inclusion Criteria:

  • Male patients aged between 18 and 80 years.

Scheduled for elective robot-assisted laparoscopic radical prostatectomy.

American Society of Anesthesiologists (ASA) physical status I, II, or III.

Willingness to provide written informed consent.

Exclusion Criteria:

  • Patient refusal to participate.

Severe obstructive or restrictive pulmonary disease (e.g., severe COPD, uncontrolled asthma).

Body Mass Index (BMI) > 35 kg/m^2.

Pre-existing severe lung pathology or active pulmonary infection.

Hemodynamic instability or severe cardiovascular disease (e.g., severe heart failure, recent myocardial infarction).

Requirement for postoperative mechanical ventilation.

Emergency surgery.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Change in Lung Ultrasound Score (LUS) From Preoperative Baseline to 24 Hours Postoperatively
Lasso di tempo: Baseline LUS0 (T0: pre-induction) and 24 hours postoperatively (LUS 2).
The primary outcome is the difference in lung aeration between preoperative baseline (LUS 0, at T0: pre-induction, awake, supine) and 24 hours postoperatively (LUS 2). Lung aeration is evaluated via a 12-region ultrasound protocol; each quadrant is scored 0-3, yielding a total of 0-36 (higher scores indicate worse aeration). This change (LUS 0 to LUS 2) will be correlated with the mean intraoperative driving pressure (ΔP = Pplat - PEEP). Mean ΔP is calculated as the average of measurements obtained at predefined intraoperative milestones: T_basal (immediately post-intubation), T1 (1st hour, immediately post-establishment of pneumoperitoneum and deep Trendelenburg), T2, T3, T4, T5 (hourly intervals during pneumoperitoneum/Trendelenburg maintenance), and T_neutral (within 10 minutes post-desufflation, return to supine).
Baseline LUS0 (T0: pre-induction) and 24 hours postoperatively (LUS 2).

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Change in Lung Ultrasound Score (LUS) From Preoperative Baseline(LUS0) to 30 Minutes Postoperatively(LUS1)
Lasso di tempo: Baseline (T0: pre-induction) and 30 minutes postoperatively (LUS 1).
This outcome assesses early postoperative lung aeration changes between baseline (LUS 0, at T0: pre-induction, awake, supine) and 30 minutes postoperatively in the post-anesthesia care unit (LUS 1). Aeration is evaluated via a 12-region ultrasound protocol (each quadrant scored 0-3; total 0-36). This acute change (LUS 0 to LUS 1) will be correlated with mean intraoperative driving pressure (ΔP = Pplat - PEEP). Mean ΔP is the average of measurements at specific milestones: T_basal (immediately post-intubation), T1 (1st hour, post-establishment of pneumoperitoneum and deep Trendelenburg), T2, T3, T4, T5 (hourly maintenance), and T_neutral (within 10 minutes post-desufflation, return to supine).
Baseline (T0: pre-induction) and 30 minutes postoperatively (LUS 1).
Correlation Between Total Anesthesia Duration and Postoperative Changes in Lung Ultrasound Scores (LUS)
Lasso di tempo: From the start of anesthesia induction until extubation (for total duration, assessed up to 6 hours) and at specific assessment points: Baseline (T0), 30 minutes postoperatively (LUS 1), and 24 hours postoperatively (LUS 2).
This outcome investigates the correlation between total anesthesia/mechanical ventilation duration (measured in minutes from T0: pre-induction to extubation) and changes in lung aeration. The clinical impact of operative time on atelectasis will be evaluated by correlating this duration with early (LUS 0 at T0 to LUS 1 at postop 30 min) and persistent (LUS 0 to LUS 2 at postop 24 hours) LUS changes. The intraoperative timeline includes predefined milestones: T_basal (post-intubation), T1 (1st hour, post-pneumoperitoneum and deep Trendelenburg), T2, T3, T4, T5 (hourly maintenance), and T_neutral (post-desufflation, return to supine).
From the start of anesthesia induction until extubation (for total duration, assessed up to 6 hours) and at specific assessment points: Baseline (T0), 30 minutes postoperatively (LUS 1), and 24 hours postoperatively (LUS 2).
Correlation of Intraoperative Mechanical Power With Changes in Lung Ultrasound Scores (LUS)
Lasso di tempo: Intraoperatively from anesthesia induction to the end of surgery (for mechanical power data collection, assessed up to 6 hours) and at Baseline (T0), 30 minutes (LUS 1), and 24 hours postoperatively (LUS 2) for ultrasound scores.
This outcome evaluates cumulative energy delivered to the respiratory system (Mechanical Power, MP) during volume-controlled ventilation. Average (MP_mean) and maximum (MP_max) MP will be retrospectively calculated via the simplified Gattinoni formula using ventilator data at milestones: T_basal (immediately post-intubation), T1 (1st hour, post-pneumoperitoneum and deep Trendelenburg), T2, T3, T4, T5 (hourly maintenance), and T_neutral (post-desufflation). These intraoperative energy metrics will be correlated with early (LUS 0 to LUS 1 at 30 min) and persistent (LUS 0 to LUS 2 at 24 hours) postoperative changes in lung aeration.
Intraoperatively from anesthesia induction to the end of surgery (for mechanical power data collection, assessed up to 6 hours) and at Baseline (T0), 30 minutes (LUS 1), and 24 hours postoperatively (LUS 2) for ultrasound scores.
Correlation Between Intraoperative Driving Pressure and Arterial Blood Gas Parameters
Lasso di tempo: Intraoperatively, at specific predefined milestones: T_basal, T1 (1st hour, immediately post-pneumoperitoneum/Trendelenburg), T2, T3, T4, T5, and T_neutral (assessed up to 6 hours).
This outcome assesses immediate physiological impacts of driving pressure (ΔP) changes induced by pneumoperitoneum and deep Trendelenburg. Arterial blood gas (ABG) parameters, specifically pH, PaO2/FiO2 ratio (Horowitz index), PaCO2, and lactate, will be correlated with the ΔP (Pplat - PEEP) measured at exact corresponding milestones: T_basal (immediately post-intubation), T1 (1st hour, immediately post-establishment of pneumoperitoneum and deep Trendelenburg), T2, T3, T4, T5 (hourly maintenance), and T_neutral (within 10 minutes post-desufflation, return to supine).
Intraoperatively, at specific predefined milestones: T_basal, T1 (1st hour, immediately post-pneumoperitoneum/Trendelenburg), T2, T3, T4, T5, and T_neutral (assessed up to 6 hours).
Incidence of Postoperative Pulmonary Complications (PPCs) and Correlation With Intraoperative Driving Pressure
Lasso di tempo: From the end of surgery (extubation) up to 24 hours postoperatively.
This outcome tracks postoperative pulmonary complications (PPCs) to evaluate the clinical impact of intraoperative ventilation. PPCs are defined as transient or persistent desaturation (SpO2 < 92%), clinical need for supplemental oxygen, or tachypnea in the PACU. This incidence is correlated with the mean intraoperative driving pressure (ΔP) calculated as the average across milestones: T_basal (post-intubation), T1 (1st hour, post-pneumoperitoneum and deep Trendelenburg), T2, T3, T4, T5 (hourly maintenance), and T_neutral (post-desufflation, return to supine). Clinical follow-up extends up to 24 hours.
From the end of surgery (extubation) up to 24 hours postoperatively.

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Stimato)

30 maggio 2026

Completamento primario (Stimato)

20 agosto 2026

Completamento dello studio (Stimato)

15 settembre 2026

Date di iscrizione allo studio

Primo inviato

5 maggio 2026

Primo inviato che soddisfa i criteri di controllo qualità

20 maggio 2026

Primo Inserito (Effettivo)

28 maggio 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

11 giugno 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

9 giugno 2026

Ultimo verificato

1 giugno 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • AEŞH-EK-2026-018

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi