- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT07768072
A Comparison Between Ischial-Containment and Sub-Ischial Prosthetic Sockets to Determine Their Effects on Secondary Health Conditions
Panoramica dello studio
Stato
Condizioni
Descrizione dettagliata
The purpose of this study is to investigate and compare the effects of the standard ischial containment (IC) socket to a sub-ischial (SI) socket design on the spinal and pelvic motions and leg length (LLD) discrepancies of transfemoral prosthesis users. Data will be collected from 2 groups of transfemoral prosthesis users (15 SI socket wearers and 15 IC socket wearers) and a group of 15 able-bodied (AB) control participants. Gait and standing analyses will be conducted on each participant using a marker based motion capture system. Prosthesis users will wear their own conventional sockets for the gait and standing analyses. Kinematic and kinetic data will be analyzed for differences between the 2 groups of socket wearers and will also be compared to the control group.
The specific aims and hypotheses of this project are:
Aim 1: To measure dynamic leg length and kinematics of the pelvis and spinal segments in unilateral, transfemoral prosthesis users during gait. Quantitative motion analyses will be performed on two groups of 15 research participants with lower limb amputation using 2 different socket designs (IC and SI) walking over level ground at three self-selected walking speeds (normal, moderately fast, fastest). Data will be compared between socket type and to an AB control group. Hypothesis 1a-IC socket wearers will have a greater anterior pelvic tilt compared to SI socket wearers and AB controls, and they will exhibit considerably greater rotations of the pelvis and spinal segments during walking. Hypothesis 1b-The EMG activity of the lumbar erector spinae for SI socket users will better approximate the patterns of AB controls as compared to IC socket wearers. Hypothesis 1c-The dynamic LLD will be greater for IC socket users compared to SI socket wearers and AB controls.
Aim 2: To measure pelvic orientation and static leg length in unilateral, transfemoral prosthesis users during standing. A multi-segment model of the spine and pelvis will be used to determine neutral spinal, pelvis, and prosthetic alignment during standing for the research and AB control participants. Hypothesis 2a-IC socket wearers will demonstrate greater anterior pelvic tilt during standing compared to SI socket wearers and control participants. Hypothesis 2b-The prosthetic and sound leg lengths for both prosthesis user groups will be within 1.0 cm of each other during standing.
Aim 3: To estimate joint contact forces in the legs and lower back of unilateral, transfemoral prosthesis users and controls during gait. Computational musculoskeletal simulations will be used to comprehensively evaluate the data from Aim 1 to compare the lumbar joint loads between IC and SI socket wearers. Hypothesis 3-IC socket wearers will exhibit greater lumbar joint loads than SI socket wearers.
Tipo di studio
Iscrizione (Stimato)
Contatti e Sedi
Contatto studio
- Nome: Rebecca Stine, MS
- Numero di telefono: (312) 503-5726
- Email: rebecca.stine@va.gov
Backup dei contatti dello studio
- Nome: Steven A Gard, PhD
- Numero di telefono: (312) 503-5718
- Email: steven.gard@va.gov
Luoghi di studio
-
-
Illinois
-
Chicago, Illinois, Stati Uniti, 60612
- Jesse Brown VA Medical Center, Chicago, IL
-
Contatto:
- Rebecca Stine, MS
- Numero di telefono: (312) 503-5726
- Email: rebecca.stine@va.gov
-
Contatto:
- Steven A Gard, PhD
- Numero di telefono: (312) 503-5718
- Email: steven.gard@va.gov
-
Investigatore principale:
- Rebecca Stine, MS
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
For all participants:
- Ability to complete the experimental protocol without undue fatigue or health risks
- Low Back Pain scale assessment (0-10) less than 4 (activities of daily living or quality of life not impacted)
In addition for persons with lower limb amputation:
- Prosthesis user for a minimum of 2 years with their current socket design
- Good fit with either an ischial containment (IC) or sub-ischial (SI) socket
- Good skin integrity on their residual limb upon visual inspection
- Does not require the use of assistive devices to walk
Exclusion Criteria:
- Previously diagnosed with a spine condition (e.g., pinched nerve, bulging disc, etc.)
- Previously diagnosed with an orthopedic or neuromuscular condition that may affect walking or balance (e.g., ankle fusion, Parkinson's disease, stroke, etc.)
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Coorti e interventi
Gruppo / Coorte |
|---|
|
Ischial Containment Socket user
Person with unilateral transfemoral amputation wearing an ischial containment socket
|
|
Sub-Ischial Socket user
Person with unilateral transfemoral amputation wearing a sub-ischial socket
|
|
Able-bodied control
Person without an amputation
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Anterior Pelvic Tilt Angle Between the IC Socket wearers and the SI Socket wearers/Able-Bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
Anterior Pelvic Tilt will be calculated for all participants during the walking and standing trials.
Participants will walk along a 10 meter walkway at varying speeds.
Quantitative motion analysis using a marker based motion measurement system will be used to calculate anterior pelvic tilt.
|
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Electromyography (EMG) Activity of the Lumbar Erector Spinae Between the IC Socket wearers and the SI Socket wearers/Able-bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
EMG activity will be assessed using surface electrodes attached bilaterally to the erector spinae at and below T12/L1 and on the external oblique muscle.
Data will be collected during the quantitative motion analysis.
|
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
|
Lumbar Flexion Between the IC Socket wearers and the SI Socket wearers/Able-bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
Lumbar flexion will be calculated for all participants during the walking and standing trials.
Participants will walk along a 10 meter walkway at varying speeds.
Quantitative motion analysis using a marker based motion measurement system will be used to calculate anterior pelvic tilt.
|
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
|
Hip Joint Range of Motion (ROM) between the IC Socket wearers and the SI Socket wearers/Able-bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
Hip Joint ROM will be calculated for all participants during the walking trials.
Participants will walk along a 10 meter walkway at varying speeds.
Quantitative motion analysis using a marker based motion measurement system will be used to calculate hip joint ROM.
|
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
|
Dynamic Leg Length Discrepancy (LLD) Between the IC Socket wearers and the SI Socket wearers/Able-bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
Dynamic LLD will be calculated for all participants during the walking trials.
Participants will walk along a 10 meter walkway at varying speeds.
Quantitative motion analysis using a marker based motion measurement system will be used to calculated dynamic LLD.
|
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
|
Peak Lumbar Joint Loading Between the IC Socket wearers and the SI Socket wearers/Able-bodied Controls
Lasso di tempo: To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
Lumbar joint loading during walking will be analyzed by performing musculoskeletal modeling simulations using data collected during the quantitative motion analysis.
|
To be measured on day 1 of the single study visit, within an estimated 3-hour timeframe
|
Collaboratori e investigatori
Investigatori
- Investigatore principale: Rebecca Stine, MS, Jesse Brown VA Medical Center, Chicago, IL
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- RRD2-014-25W
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .