Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Clinical Evaluation of NIRSense Tissue Oximetry Sensor Monitoring to Early Detect Cardiogenic Shock

13 settembre 2026 aggiornato da: NIRSense Inc.

Clinical Evaluation of Using NIRSense Sensor Patch to Measure Microvascular Perfusion Responses and Predict Decompensation in Cardiogenic Shock Patients

This is a prospective, single-center, observational pilot study of the investigational NIRSense Tissue Oximetry Sensor System (Envello Core), a noninvasive wearable sensor patch that uses near-infrared spectroscopy (NIRS) and photoplethysmography (PPG), combined with an electrocardiography/impedance cardiography (ECG/ICG) sensor, to continuously monitor tissue oxygen saturation (StO2), peripheral oxygen saturation (SpO2), pulse rate, respiratory rate, stroke volume, and related metrics. Up to 20 adults admitted to the Cleveland Clinic Florida cardiac intensive care unit with acute myocardial infarction or acute decompensated heart failure and in Society for Cardiovascular Angiography and Interventions (SCAI) shock stage B, C, or D will wear the sensors on the sternum, forearm, and other locations for approximately 24 to 72 hours during standard care. Sensor data will be compared with standard-of-care hemodynamic and laboratory measurements and with the patient's clinical course to evaluate the feasibility of the device, the correlation of its measurements with established clinical parameters, and its potential to detect deterioration in SCAI shock stage earlier. No treatment decisions are made based on the study device.

Panoramica dello studio

Descrizione dettagliata

Background: Cardiogenic shock (CS) carries a poor prognosis and is the leading cause of death in patients with acute myocardial infarction. When decompensation occurs there is an imperative to institute treatment rapidly. Standard intensive care unit monitoring relies on intermittent hemodynamic and laboratory measures. Continuous, noninvasive measurement of tissue perfusion and oxygenation could allow earlier recognition of deterioration and earlier intervention.

Device: The NIRSense Tissue Oximetry Sensor System is an investigational, non-significant-risk, noninvasive wearable optical physiological monitoring system. It consists of a sensor patch with multiple red and near-infrared light sources and detectors (NIRS and PPG), a pre-applied medical-grade adhesive, an ECG/ICG sensor patch, and a display unit (tablet running the NIRSense application) that receives data over Bluetooth and stores it. The sensor estimates StO2 in microvascular tissue up to about 2.5 cm below the skin and derives PPG-based metrics including pulse rate, respiratory rate, and perfusion index. The device has not been cleared or approved by the U.S. FDA.

Design: Prospective data collection, single-center observational study. Two populations are targeted: (1) patients with acute myocardial infarction, with or without shock (SCAI B to D), admitted for coronary angiography and subsequent interventions, and (2) patients with acute decompensated heart failure admitted for pulmonary artery catheter insertion and subsequent interventions. Participants are enrolled from the existing Cleveland Clinic Florida patient population in a way that avoids disruption of clinical workflow. After informed consent, sensors are placed on the sternum, forearm, and other locations according to manufacturer specifications and remain in place while the patient is in the cardiac intensive care unit, for approximately 24 to 72 hours. Sensors may be repositioned during catheterization or imaging at the investigator's discretion. Participation is limited to the single standard-of-care admission; there is no study follow-up visit or call.

Data collected: Continuous sensor data (StO2, SpO2, pulse rate, respiratory rate, ECG/ICG-derived stroke volume, PPG-derived metrics) and sensor placement images. Data collected during standard-of-care treatment and shared with the sponsor: demographics, Fitzpatrick skin type, medical history, concomitant medications, physical examination, vital signs, a single 12-lead ECG, blood pressure, heart rate, cardiac output (thermodilution) where obtained, clinically ordered lactate values, SCAI stage, and clinical course. Adverse events and device deficiencies are recorded from enrollment through sensor removal. Clinical staff complete a usability survey after using the device on 5 patients.

Analysis: Descriptive statistics for demographics and baseline characteristics; adverse events summarized by frequency and percentage, severity, and device relatedness. Effectiveness analyses use all evaluable data and compare device measurements with standard-of-care hemodynamic parameters and with SCAI stage trajectory, as specified in the Statistical Analysis Plan. Following an interim analysis of the 20-patient pilot, enrollment may be expanded to 200 patients under a protocol amendment; that expansion is not part of this record.

Tipo di studio

Osservativo

Iscrizione (Stimato)

20

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Contatto studio

Luoghi di studio

    • Florida
      • Weston, Florida, Stati Uniti, 33331
        • Reclutamento
        • Cleveland Clinic Florida, Weston Hospital
        • Contatto:
          • David A. Baran, MD
          • Numero di telefono: 954-659-5290
          • Email: barand@ccf.org
        • Contatto:
        • Investigatore principale:
          • David A. Baran, MD

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto
  • Adulto più anziano

Accetta volontari sani

No

Metodo di campionamento

Campione non probabilistico

Popolazione di studio

Adults admitted to the Cleveland Clinic Florida cardiac intensive care unit with acute myocardial infarction undergoing coronary angiography, or with acutely decompensated heart failure, who are in SCAI shock stage B, C, or D. Participants are recruited from the existing patient population of the recruitment site.

Descrizione

Inclusion Criteria:

  • Acutely decompensated symptomatic heart failure (HF) documented by: (a) symptoms of HF requiring current treatment; (b) Society for Cardiovascular Angiography and Interventions (SCAI) stage B, C, or D; and (c) hospital admission with HF as the primary or secondary diagnosis; OR acute myocardial infarction (MI) patient undergoing coronary angiography
  • Admitted to the intensive care unit and currently in SCAI stage B, C, or D
  • Age 18 years or older
  • Weight greater than 40 kg

Exclusion Criteria:

  • Prior known severe allergy to medical-grade adhesive or tape (self-reported)
  • Currently participating in an investigational drug or device study that would interfere with the conduct or results of this study. Trials requiring extended follow-up for products that were investigational but have since become commercially available are not considered investigational.
  • The investigator believes the participant is not an appropriate candidate for the study

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

Coorti e interventi

Gruppo / Coorte
Intervento / Trattamento
Acute myocardial infarction
Patients with acute myocardial infarction, with or without shock (SCAI stage B to D), admitted for coronary angiography and subsequent interventions. Enrolled at the time of consent for coronary angiography.
Investigational noninvasive wearable sensor patches using near-infrared spectroscopy and photoplethysmography to continuously measure tissue oxygen saturation, SpO2, pulse rate, respiratory rate, and perfusion index, plus an ECG/ICG sensor patch for stroke volume, with a tablet display and recording application. Sensors are applied to the sternum, forearm, and other locations with a medical-grade adhesive and worn for approximately 24 to 72 hours during standard cardiac ICU care. Sensor data are collected for research only and are not used for treatment decisions.
Altri nomi:
  • Envello Core
  • NIRSense Sensor Oximetry System patch
Acute decompensated heart failure
Patients with acute decompensated heart failure (SCAI stage B to D) admitted for pulmonary artery catheter insertion and subsequent interventions. Consented before or after catheterization.
Investigational noninvasive wearable sensor patches using near-infrared spectroscopy and photoplethysmography to continuously measure tissue oxygen saturation, SpO2, pulse rate, respiratory rate, and perfusion index, plus an ECG/ICG sensor patch for stroke volume, with a tablet display and recording application. Sensors are applied to the sternum, forearm, and other locations with a medical-grade adhesive and worn for approximately 24 to 72 hours during standard cardiac ICU care. Sensor data are collected for research only and are not used for treatment decisions.
Altri nomi:
  • Envello Core
  • NIRSense Sensor Oximetry System patch

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Correlation between NIRSense sensor measurements and standard-of-care hemodynamic parameters
Lasso di tempo: Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application
Correlation coefficients (Pearson and Spearman) between time-matched NIRSense measurements (tissue oxygen saturation, perfusion index, SpO2, pulse rate, respiratory rate, ICG-derived stroke volume) and standard-of-care clinical measurements (arterial blood pressure, heart rate, pulmonary artery and central venous pressures where a pulmonary artery catheter is present, cardiac output by thermodilution, and lactate).
Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Feasibility: proportion of intended monitoring time with valid sensor data
Lasso di tempo: Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application
Percentage of the intended monitoring period during which each sensor provided valid StO2 and PPG data, per sensor site, including data recovered from onboard memory after wireless transmission gaps.
Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application
Patient tolerance: device-related adverse events and device deficiencies
Lasso di tempo: From enrollment through sensor removal, approximately 24 to 72 hours
Number and percentage of participants with adverse events, adverse device effects (including skin irritation or redness at the adhesive site), and device deficiencies, and number of participants requesting early sensor removal.
From enrollment through sensor removal, approximately 24 to 72 hours
Association between NIRSense measurement trends and change in SCAI shock stage
Lasso di tempo: Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application
Change in NIRSense measurements (StO2, StO2 variability, perfusion index, stroke volume) relative to the time of clinically documented change in SCAI shock stage, including the lead time between the first sustained change in device metrics and the clinically recognized deterioration.
Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application
Distribution of NIRSense measurements by SCAI shock stage
Lasso di tempo: Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application
Summary statistics of StO2, perfusion index, and ICG-derived stroke volume at each sensor site by SCAI shock stage (B, C, D, E), to inform development of a predictive model of shock status.
Continuous monitoring during the cardiac ICU stay, approximately 24 to 72 hours from sensor application

Altre misure di risultato

Misura del risultato
Misura Descrizione
Lasso di tempo
Clinical staff usability feedback
Lasso di tempo: After the device has been used on 5 patients (approximately 1 to 6 months after first enrollment)
Responses to a paper survey completed by study staff (principal investigator, nurses, residents, and others involved in the study) on their experience using the sensor system.
After the device has been used on 5 patients (approximately 1 to 6 months after first enrollment)

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Sponsor

Collaboratori

Investigatori

  • Investigatore principale: David A. Baran, MD, Cleveland Clinic Florida
  • Direttore dello studio: Thibault Roumengous, PhD, NIRSense Inc.

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

17 giugno 2025

Completamento primario (Stimato)

1 gennaio 2027

Completamento dello studio (Stimato)

1 agosto 2027

Date di iscrizione allo studio

Primo inviato

13 settembre 2026

Primo inviato che soddisfa i criteri di controllo qualità

13 settembre 2026

Primo Inserito (Effettivo)

17 settembre 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

17 settembre 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

13 settembre 2026

Ultimo verificato

1 settembre 2026

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

INDECISO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

Sì

prodotto fabbricato ed esportato dagli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi