Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness†
J Mallat, M Meddour, E Durville, M Lemyze, F Pepy, J Temime, N Vangrunderbeeck, L Tronchon, D Thevenin, B Tavernier, J Mallat, M Meddour, E Durville, M Lemyze, F Pepy, J Temime, N Vangrunderbeeck, L Tronchon, D Thevenin, B Tavernier
Abstract
Background: Dynamic indices, such as pulse pressure variation (PPV), are inaccurate predictors of fluid responsiveness in mechanically ventilated patients with low tidal volume. This study aimed to test whether changes in continuous cardiac index (CCI), PPV, and stroke volume variation (SVV) after a mini-fluid challenge (100 ml of fluid during 1 min) could predict fluid responsiveness in these patients.
Methods: We prospectively studied 49 critically ill, deeply sedated, and mechanically ventilated patients (tidal volume <8 ml kg(-1) of ideal body weight) without cardiac arrhythmias, in whom a fluid challenge was indicated because of circulatory failure. The CCI, SVV (PiCCO™; Pulsion), and PPV (MP70™; Philips) were measured before and after 100 ml of colloid infusion during 1 min, and then after the additional infusion of 400 ml during 14 min. Responders were defined as subjects with a ≥15% increase in cardiac index (transpulmonary thermodilution) after the full (500 ml) fluid challenge. Areas under the receiver operating characteristic curves (AUCs) and the grey zones were determined for changes in CCI (ΔCCI100), SVV (ΔSVV100), and PPV (ΔPPV100) after 100 ml fluid challenge.
Results: Twenty-two subjects were responders. The ΔCCI100 predicted fluid responsiveness with an AUC of 0.78. The grey zone was large and included 67% of subjects. The ΔSVV100 and ΔPPV100 predicted fluid responsiveness with AUCs of 0.91 and 0.92, respectively. Grey zones were small, including ≤12% of subjects for both indices.
Conclusions: The ΔSVV100 and ΔPPV100 predict fluid responsiveness accurately and better than ΔCCI100 (PiCCO™; Pulsion) in patients with circulatory failure and ventilated with low volumes.
Keywords: cardiac output; fluid therapy; goal-directed therapy; haemodynamics; monitoring; pulse pressure.
© The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Source: PubMed
Prossimi studi clinici
-
Magnus MedicalCongressionally Directed Medical Research ProgramsReclutamento
-
Nicholas ButowskiSiren BiotechnologyNon ancora reclutamentoGlioma | Neoplasia cerebrale | Gliomi ricorrenti di alto gradoStati Uniti
-
State University of New York at BuffaloNon ancora reclutamentoCoinvolgimento del pazienteStati Uniti
-
Poitiers University HospitalNon ancora reclutamento
-
Assistance Publique - Hôpitaux de ParisNon ancora reclutamentoAnemia falciforme | Crisi vaso-occlusiva
-
University of California, IrvineReclutamentoCancro al cervello | Cancro al SNC | Cancro del sistema nervoso | Metastasi del Cancro al CervelloStati Uniti
-
Qualia Life SciencesReclutamento
-
Guangdong Raynovent Biotech Co., LtdNon ancora reclutamento
-
The Hong Kong Polytechnic UniversityWu Jieh Yee Charitable FoundationReclutamentoAdulti | Assistenza digitale per ipovedenti | Deficit VisiviHong Kong
-
Shanghai General Hospital, Shanghai Jiao Tong University...Non ancora reclutamentoAdenocarcinoma duttale pancreatico (PDAC)
-
Sun Yat-sen UniversityNon ancora reclutamentoSmettere di fumare | Agente AI | Early-Stage Cancer
-
Affiliated Hospital of Nantong UniversityNon ancora reclutamento