Decrease in pulse pressure and stroke volume variations after mini-fluid challenge accurately predicts fluid responsiveness†
J Mallat, M Meddour, E Durville, M Lemyze, F Pepy, J Temime, N Vangrunderbeeck, L Tronchon, D Thevenin, B Tavernier, J Mallat, M Meddour, E Durville, M Lemyze, F Pepy, J Temime, N Vangrunderbeeck, L Tronchon, D Thevenin, B Tavernier
Abstract
Background: Dynamic indices, such as pulse pressure variation (PPV), are inaccurate predictors of fluid responsiveness in mechanically ventilated patients with low tidal volume. This study aimed to test whether changes in continuous cardiac index (CCI), PPV, and stroke volume variation (SVV) after a mini-fluid challenge (100 ml of fluid during 1 min) could predict fluid responsiveness in these patients.
Methods: We prospectively studied 49 critically ill, deeply sedated, and mechanically ventilated patients (tidal volume <8 ml kg(-1) of ideal body weight) without cardiac arrhythmias, in whom a fluid challenge was indicated because of circulatory failure. The CCI, SVV (PiCCO™; Pulsion), and PPV (MP70™; Philips) were measured before and after 100 ml of colloid infusion during 1 min, and then after the additional infusion of 400 ml during 14 min. Responders were defined as subjects with a ≥15% increase in cardiac index (transpulmonary thermodilution) after the full (500 ml) fluid challenge. Areas under the receiver operating characteristic curves (AUCs) and the grey zones were determined for changes in CCI (ΔCCI100), SVV (ΔSVV100), and PPV (ΔPPV100) after 100 ml fluid challenge.
Results: Twenty-two subjects were responders. The ΔCCI100 predicted fluid responsiveness with an AUC of 0.78. The grey zone was large and included 67% of subjects. The ΔSVV100 and ΔPPV100 predicted fluid responsiveness with AUCs of 0.91 and 0.92, respectively. Grey zones were small, including ≤12% of subjects for both indices.
Conclusions: The ΔSVV100 and ΔPPV100 predict fluid responsiveness accurately and better than ΔCCI100 (PiCCO™; Pulsion) in patients with circulatory failure and ventilated with low volumes.
Keywords: cardiac output; fluid therapy; goal-directed therapy; haemodynamics; monitoring; pulse pressure.
© The Author 2015. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Source: PubMed
Предстоящие клинические испытания
-
Magnus MedicalCongressionally Directed Medical Research ProgramsРекрутинг
-
Nicholas ButowskiSiren BiotechnologyЕще не набираютГлиома | Новообразование головного мозга | Рецидивирующие глиомы высокой степени злокачественностиСоединенные Штаты
-
State University of New York at BuffaloЕще не набираютВовлечение пациентовСоединенные Штаты
-
Poitiers University HospitalЕще не набирают
-
Assistance Publique - Hôpitaux de ParisЕще не набираютСерповидно-клеточная анемия | Вазоокклюзионный кризис
-
University of California, IrvineРекрутингРак мозга | Рак ЦНС | Рак нервной системы | Метастатический рак головного мозгаСоединенные Штаты
-
Qualia Life SciencesРекрутинг
-
Guangdong Raynovent Biotech Co., LtdЕще не набираютФундаментальная наука
-
The Hong Kong Polytechnic UniversityWu Jieh Yee Charitable FoundationРекрутингВзрослые люди | Цифровая помощь для слабовидящих | Нарушения зренияГонконг
-
Shanghai General Hospital, Shanghai Jiao Tong University...Еще не набираютАденокарцинома протоков поджелудочной железы (PDAC)
-
Sun Yat-sen UniversityЕще не набираютОтказ от курения | ИИ-агент | Early-Stage Cancer
-
Affiliated Hospital of Nantong UniversityЕще не набирают