Evaluation of the Accuracy and Precision of the Masimo Labs Pulse-Hemoglobin-Meter Monitor in Surgical Patients
調査の概要
状態
詳細な説明
Blood hemoglobin concentration is a very common and essential test to assess patient well being and the need for blood transfusion. In the perioperative period this measurement is further more critical mainly due to the acute nature of blood loss and the need for an immediate response. Currently, hemoglobin concentration is determined by analyzing a blood sample. It requires venipuncture or arterial puncture (via an arterial line). Besides the patient discomfort there are additional disadvantages such as infection, dealing with blood product, delay with diagnosis, low update rate and cost. Masimo Labs is in the process of developing a noninvasive monitor to detect hemoglobin concentrations in real time. The monitor uses a probe placed on the patient finger that gives hemoglobin concentration continuously and noninvasively. Masimo Labs is using a technology that resembles the well accepted and clinically proven pulse-oxymeter.
The study will include surgical patients at the UCI Medical Center, preferably in cases that are known to involve major blood loss. For these cases, the anesthesia team places an arterial line for anesthesia purposes. The arterial line is used for continuous blood pressure measurements and blood draw for the assessment of several indices. We plan to compare the hemoglobin concentrations measured from blood samples to the Masimo Labs pulse-hemoglobin level readings.
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
California
-
Orange、California、アメリカ、92868
- Univeristy of California Irvine Medical Center
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- Adult having surgery with arterial line
Exclusion Criteria:
- Upper extremities surgery
- Pregnant women
- Children
研究計画
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
介入・治療 |
|---|---|
|
Adult patient undergoing a surgery
Adult patient undergoing a surgery in the supine position and require an arterial line for anesthesia/surgery purposes
|
Placing a probe on the finger
drawing a blood sample less that 0.5 mL each time, for around 10-12 times along the surgery (depends on surgical time)
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
corrlation of up to +/-0.1 gr% of the blood analysis to the monitor reading
時間枠:1 year
|
1 year
|
協力者と研究者
協力者
捜査官
- 主任研究者:Abraham Rosenbaum, MD、University of California, Irvine
研究記録日
主要日程の研究
研究開始
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- 2008-6221
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。