このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Clinical Outcome of Birmingham Hip Resurfacing (BHR) Using VISIONAIRE Femoral Alignment Guide (BHR)

2018年3月21日 更新者:Smith & Nephew, Inc.

Prospective, Multi- Site, Clinical Study of Clinical Outcomes Following Hip Resurfacing Using VISIONAIRE Femoral Alignment Guide

The primary objective of this study is to investigate the accuracy of the femoral implant placement utilizing the VISIONAIRE Femoral Alignment Guide in Birmingham Hip Resurfacing (BHR) surgery postoperatively after total hip resurfacing using the BHR System.

調査の概要

状態

完了

詳細な説明

This is a prospective, multi- site, clinical study of clinical outcomes following hip resurfacing using VISIONAIRE Femoral Alignment Guide. The objective of this study is to evaluate the safety and efficacy of the blocks and to assess alignment of the BHR system when using VISIONAIRE Femoral Alignment Guide. This study will also document any device-related surgical complications or adverse radiographic observations.

研究の種類

観察的

入学 (実際)

25

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • Ontario
      • London、Ontario、カナダ、N6G 1G9
        • London Health Science Centers
      • Toronto、Ontario、カナダ、M5C 1R6
        • Sr. Michaels Hospital

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年~75年 (大人、高齢者)

健康ボランティアの受け入れ

はい

受講資格のある性別

全て

サンプリング方法

非確率サンプル

調査対象母集団

The patient population considered for this study is patients requiring total hip resurfacing. The following inclusion and exclusion criteria will be used to identify study candidates.

説明

Inclusion Criteria:

  1. Males or females, at least 21 years of age, inclusive, and skeletally mature.
  2. Patient diagnosed with osteoarthritis of the hip requiring primary total hip resurfacing due to:

    • Non-inflammatory arthritis (degenerative joint disease) such as osteoarthritis, traumatic arthritis, avascular necrosis, or dysplasia/DDH, or
    • Inflammatory arthritis such as rheumatoid arthritis.
  3. Patient is willing to consent to participate in the study
  4. Patient is in stable health and is free of or treated and stabilized for cardiac, pulmonary, hematological, or other conditions that would pose excessive operative risk.
  5. Patient meets medical clearance to have surgery required for this study

Exclusion Criteria:

  1. Patient with infection or sepsis.
  2. Patient with any vascular insufficiency, muscular atrophy, or neuromuscular disease severe enough to compromise implant stability or postoperative recovery.
  3. Patient is pregnant or plans to become pregnant during the course of the study.
  4. Patient known to have insufficient bone stock to support the BHR device including:

    • Subjects with severe osteopenia should not receive a BHR procedure. Patients with a family history of severe osteoporosis or severe osteopenia.
    • Subjects with osteonecrosis or avascular necrosis (AVN) with >50% involvement of the femoral head (regardless of FICAT Grade) should not receive a BHR.
    • Subjects with multiple cysts of the femoral head (>1cm) should not receive a BHR.
    • Note: In cases of questionable bone stock, a DEXA scan may be necessary to assess inadequate bone stock.
  5. Patient has known moderate to severe renal insufficiency. Subjects on medications (such as high-dose or chronic aminoglycoside treatment) or with co-morbidities (such as diabetes) that increase the risk of future, significant renal impairment should be advised of the possibility of increase in systemic metal ion concentration.
  6. Patient has a known sensitivity to materials in the device.
  7. Patient is immuno-suppressed.
  8. Patient has physical, emotional or neurological conditions that would compromise the patient's compliance with postoperative rehabilitation and follow-up.
  9. Patient has BMI >40.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Investigate the accuracy of the femoral implant placement utilizing the VISIONAIRE Femoral Alignment Guide in BHR surgery postoperatively after total hip resurfacing using the BHR System
時間枠:6 week
Radiographic evaluation of postoperative femoral stem angle.
6 week

二次結果の測定

結果測定
メジャーの説明
時間枠
Number of Participants with Adverse Events as a Measure of Safety and Tolerability
時間枠:6 week and 6 month
Surgical and device related adverse events or revision
6 week and 6 month

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始

2009年10月1日

一次修了 (実際)

2011年8月1日

研究の完了 (実際)

2011年8月1日

試験登録日

最初に提出

2010年8月6日

QC基準を満たした最初の提出物

2011年8月31日

最初の投稿 (見積もり)

2011年9月1日

学習記録の更新

投稿された最後の更新 (実際)

2018年3月22日

QC基準を満たした最後の更新が送信されました

2018年3月21日

最終確認日

2018年3月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • US-CR-135

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

3
購読する