The Comparative Study of OCT,Gemstone CT and 320-detector Row Spiral CT for Evaluating Restenosis of Coronary Artery Stent

2014年8月18日 更新者:Xuzhou Central Hospital

In-stent restenosis is a major reason of coronary heart disease recurrence .Even in drug eluting stent(DES), Restenosis rate could be up to 10% in diabetes and complex lesions though it was about 3-5% in general. It is particularly important that in-stent restenosis after implantation was early diagnosed and detected. The evaluation of OCT imaging is more accurate for narrow area calculation, more clear for narrow organization structure and more specific for detecting tissue types.It is currently the best way for restenosis histologic diagnosis.But it has many weakness such as the higher cost,an invasive test, expensive instrument, relatively complicated to operate,and etc.In this study, OCT image was regard as the "gold standard" of stent restenosis.

The improvement of spatial resolution of Gemstone CT can effectively improve the imaging quality and the measurement's accuracy of coronary artery stents.The diagnostic value of in-stent restenosis of Gemstone CT is higher than of the 320-detector row spiral CT. To a certain extent, the gemstone CT can replace OCT for examining the in-stent restenosis.

This study will examine the degree of in-stent restenosis by the gemstone CT and the 320-detector row spiral CT and compare the two ways on the basis of the result of OCT.

調査の概要

研究の種類

介入

入学 (予想される)

150

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • Jiangsu
      • Xuzhou、Jiangsu、中国、221000
        • 募集
        • Xuzhou Central Hospital

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

20年~80年 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  1. Age 20-80, All genders
  2. Unlimited time of implantation of coronary artery stents
  3. Myocardial ischemia symptoms such as Chest tightness and/or chest pain in patients after stent implantation
  4. No clinical symptoms, but myocardial ischemia suggested by other noninvasive tests
  5. Routine re-testing 9-12 months after stent implantation.

Exclusion Criteria:

  1. Renal insufficiency (serum creatinine > 120 umol/L)
  2. Allergy of contrast
  3. Severe heart failure
  4. Uncontrollable heart rate or contraindication of taking metoprolol
  5. Unstable condition
  6. the ventricular rate beyond 70 beats / min and irregular rhythm after adjusting.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:診断
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Gemstone CT
Gemstone CT :Discovery CT750 HD(high definition) ,GE(General Electric Co.) Healthcare, Milwaukee; CT image for patient with suspected in-stent restenosis which Gemstone CT or 320-detector row spiral CT was assigned randomly to patient
Gemstone CT or 320-detector row spiral CT was assigned randomly to patient who was suspected in-stent restenosis.About after 10 days,they would accept the check of OCT which wold be the "gold standard" of in-stent restenosis.
他の名前:
  • 10月
  • Gemstone CT
  • 320-detector row spiral CT
アクティブコンパレータ:320-detector row spiral CT
320-detector row spiral CT:Aquilion One, Toshiba, Nasu, Japan. CT image for patient with suspected in-stent restenosis which Gemstone CT or 320-detector row spiral CT was assigned randomly to patient .
Gemstone CT or 320-detector row spiral CT was assigned randomly to patient who was suspected in-stent restenosis.About after 10 days,they would accept the check of OCT which wold be the "gold standard" of in-stent restenosis.
他の名前:
  • 10月
  • Gemstone CT
  • 320-detector row spiral CT

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Accuracy of detection of in-stent restenosis with the gemstone CT as compared to the 320-detector row spiral CT will be investigated
時間枠:On the day in which a patient receives the gemstone CT and the 320-detector row spiral CT, estimated to take 10 mins
Masked examiners (CT specialists) will evaluate and compare the degree of in-stent restenosis of the gemstone CT and the 320-detector row spiral CT images for the presence and features of in-stent restenosis. In this study, OCT image was regard as the "gold standard" of in-stent restenosis.
On the day in which a patient receives the gemstone CT and the 320-detector row spiral CT, estimated to take 10 mins

二次結果の測定

結果測定
メジャーの説明
時間枠
Radiation burden of the the gemstone CT or the 320-detector row spiral CT and OCT
時間枠:one month
In a relatively short time,the patient will accept the two checks of CT and OCT(Interval period about 10 days).So,it is necessary to clear the reacts of these patients
one month

その他の成果指標

結果測定
時間枠
Measurement of the physical characteristics of in-stent restenosis structures seen on OCT
時間枠:On the day in which a patient receives the check of OCT
On the day in which a patient receives the check of OCT

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始

2014年6月1日

一次修了 (予想される)

2016年12月1日

研究の完了 (予想される)

2016年12月1日

試験登録日

最初に提出

2014年8月10日

QC基準を満たした最初の提出物

2014年8月18日

最初の投稿 (見積もり)

2014年8月19日

学習記録の更新

投稿された最後の更新 (見積もり)

2014年8月19日

QC基準を満たした最後の更新が送信されました

2014年8月18日

最終確認日

2014年8月1日

詳しくは

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。