The Comparative Study of OCT,Gemstone CT and 320-detector Row Spiral CT for Evaluating Restenosis of Coronary Artery Stent

18 août 2014 mis à jour par: Xuzhou Central Hospital

In-stent restenosis is a major reason of coronary heart disease recurrence .Even in drug eluting stent(DES), Restenosis rate could be up to 10% in diabetes and complex lesions though it was about 3-5% in general. It is particularly important that in-stent restenosis after implantation was early diagnosed and detected. The evaluation of OCT imaging is more accurate for narrow area calculation, more clear for narrow organization structure and more specific for detecting tissue types.It is currently the best way for restenosis histologic diagnosis.But it has many weakness such as the higher cost,an invasive test, expensive instrument, relatively complicated to operate,and etc.In this study, OCT image was regard as the "gold standard" of stent restenosis.

The improvement of spatial resolution of Gemstone CT can effectively improve the imaging quality and the measurement's accuracy of coronary artery stents.The diagnostic value of in-stent restenosis of Gemstone CT is higher than of the 320-detector row spiral CT. To a certain extent, the gemstone CT can replace OCT for examining the in-stent restenosis.

This study will examine the degree of in-stent restenosis by the gemstone CT and the 320-detector row spiral CT and compare the two ways on the basis of the result of OCT.

Aperçu de l'étude

Type d'étude

Interventionnel

Inscription (Anticipé)

150

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Jiangsu
      • Xuzhou, Jiangsu, Chine, 221000
        • Recrutement
        • Xuzhou Central Hospital

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

20 ans à 80 ans (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  1. Age 20-80, All genders
  2. Unlimited time of implantation of coronary artery stents
  3. Myocardial ischemia symptoms such as Chest tightness and/or chest pain in patients after stent implantation
  4. No clinical symptoms, but myocardial ischemia suggested by other noninvasive tests
  5. Routine re-testing 9-12 months after stent implantation.

Exclusion Criteria:

  1. Renal insufficiency (serum creatinine > 120 umol/L)
  2. Allergy of contrast
  3. Severe heart failure
  4. Uncontrollable heart rate or contraindication of taking metoprolol
  5. Unstable condition
  6. the ventricular rate beyond 70 beats / min and irregular rhythm after adjusting.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Diagnostique
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Gemstone CT
Gemstone CT :Discovery CT750 HD(high definition) ,GE(General Electric Co.) Healthcare, Milwaukee; CT image for patient with suspected in-stent restenosis which Gemstone CT or 320-detector row spiral CT was assigned randomly to patient
Gemstone CT or 320-detector row spiral CT was assigned randomly to patient who was suspected in-stent restenosis.About after 10 days,they would accept the check of OCT which wold be the "gold standard" of in-stent restenosis.
Autres noms:
  • OCT
  • Gemstone CT
  • 320-detector row spiral CT
Comparateur actif: 320-detector row spiral CT
320-detector row spiral CT:Aquilion One, Toshiba, Nasu, Japan. CT image for patient with suspected in-stent restenosis which Gemstone CT or 320-detector row spiral CT was assigned randomly to patient .
Gemstone CT or 320-detector row spiral CT was assigned randomly to patient who was suspected in-stent restenosis.About after 10 days,they would accept the check of OCT which wold be the "gold standard" of in-stent restenosis.
Autres noms:
  • OCT
  • Gemstone CT
  • 320-detector row spiral CT

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Accuracy of detection of in-stent restenosis with the gemstone CT as compared to the 320-detector row spiral CT will be investigated
Délai: On the day in which a patient receives the gemstone CT and the 320-detector row spiral CT, estimated to take 10 mins
Masked examiners (CT specialists) will evaluate and compare the degree of in-stent restenosis of the gemstone CT and the 320-detector row spiral CT images for the presence and features of in-stent restenosis. In this study, OCT image was regard as the "gold standard" of in-stent restenosis.
On the day in which a patient receives the gemstone CT and the 320-detector row spiral CT, estimated to take 10 mins

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Radiation burden of the the gemstone CT or the 320-detector row spiral CT and OCT
Délai: one month
In a relatively short time,the patient will accept the two checks of CT and OCT(Interval period about 10 days).So,it is necessary to clear the reacts of these patients
one month

Autres mesures de résultats

Mesure des résultats
Délai
Measurement of the physical characteristics of in-stent restenosis structures seen on OCT
Délai: On the day in which a patient receives the check of OCT
On the day in which a patient receives the check of OCT

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 juin 2014

Achèvement primaire (Anticipé)

1 décembre 2016

Achèvement de l'étude (Anticipé)

1 décembre 2016

Dates d'inscription aux études

Première soumission

10 août 2014

Première soumission répondant aux critères de contrôle qualité

18 août 2014

Première publication (Estimation)

19 août 2014

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Estimation)

19 août 2014

Dernière mise à jour soumise répondant aux critères de contrôle qualité

18 août 2014

Dernière vérification

1 août 2014

Plus d'information

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

Essais cliniques sur Maladie coronarienne

3
S'abonner