The Comparative Study of OCT,Gemstone CT and 320-detector Row Spiral CT for Evaluating Restenosis of Coronary Artery Stent
In-stent restenosis is a major reason of coronary heart disease recurrence .Even in drug eluting stent(DES), Restenosis rate could be up to 10% in diabetes and complex lesions though it was about 3-5% in general. It is particularly important that in-stent restenosis after implantation was early diagnosed and detected. The evaluation of OCT imaging is more accurate for narrow area calculation, more clear for narrow organization structure and more specific for detecting tissue types.It is currently the best way for restenosis histologic diagnosis.But it has many weakness such as the higher cost,an invasive test, expensive instrument, relatively complicated to operate,and etc.In this study, OCT image was regard as the "gold standard" of stent restenosis.
The improvement of spatial resolution of Gemstone CT can effectively improve the imaging quality and the measurement's accuracy of coronary artery stents.The diagnostic value of in-stent restenosis of Gemstone CT is higher than of the 320-detector row spiral CT. To a certain extent, the gemstone CT can replace OCT for examining the in-stent restenosis.
This study will examine the degree of in-stent restenosis by the gemstone CT and the 320-detector row spiral CT and compare the two ways on the basis of the result of OCT.
Přehled studie
Postavení
Podmínky
Intervence / Léčba
Typ studie
Zápis (Očekávaný)
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
Jiangsu
-
Xuzhou, Jiangsu, Čína, 221000
- Nábor
- Xuzhou Central Hospital
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Age 20-80, All genders
- Unlimited time of implantation of coronary artery stents
- Myocardial ischemia symptoms such as Chest tightness and/or chest pain in patients after stent implantation
- No clinical symptoms, but myocardial ischemia suggested by other noninvasive tests
- Routine re-testing 9-12 months after stent implantation.
Exclusion Criteria:
- Renal insufficiency (serum creatinine > 120 umol/L)
- Allergy of contrast
- Severe heart failure
- Uncontrollable heart rate or contraindication of taking metoprolol
- Unstable condition
- the ventricular rate beyond 70 beats / min and irregular rhythm after adjusting.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Diagnostický
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
---|---|
Experimentální: Gemstone CT
Gemstone CT :Discovery CT750 HD(high definition) ,GE(General Electric Co.) Healthcare, Milwaukee; CT image for patient with suspected in-stent restenosis which Gemstone CT or 320-detector row spiral CT was assigned randomly to patient
|
Gemstone CT or 320-detector row spiral CT was assigned randomly to patient who was suspected in-stent restenosis.About after 10 days,they would accept the check of OCT which wold be the "gold standard" of in-stent restenosis.
Ostatní jména:
|
Aktivní komparátor: 320-detector row spiral CT
320-detector row spiral CT:Aquilion One, Toshiba, Nasu, Japan.
CT image for patient with suspected in-stent restenosis which Gemstone CT or 320-detector row spiral CT was assigned randomly to patient .
|
Gemstone CT or 320-detector row spiral CT was assigned randomly to patient who was suspected in-stent restenosis.About after 10 days,they would accept the check of OCT which wold be the "gold standard" of in-stent restenosis.
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
---|---|---|
Accuracy of detection of in-stent restenosis with the gemstone CT as compared to the 320-detector row spiral CT will be investigated
Časové okno: On the day in which a patient receives the gemstone CT and the 320-detector row spiral CT, estimated to take 10 mins
|
Masked examiners (CT specialists) will evaluate and compare the degree of in-stent restenosis of the gemstone CT and the 320-detector row spiral CT images for the presence and features of in-stent restenosis.
In this study, OCT image was regard as the "gold standard" of in-stent restenosis.
|
On the day in which a patient receives the gemstone CT and the 320-detector row spiral CT, estimated to take 10 mins
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
---|---|---|
Radiation burden of the the gemstone CT or the 320-detector row spiral CT and OCT
Časové okno: one month
|
In a relatively short time,the patient will accept the two checks of CT and OCT(Interval period about 10 days).So,it is necessary to clear the reacts of these patients
|
one month
|
Další výstupní opatření
Měření výsledku |
Časové okno |
---|---|
Measurement of the physical characteristics of in-stent restenosis structures seen on OCT
Časové okno: On the day in which a patient receives the check of OCT
|
On the day in which a patient receives the check of OCT
|
Spolupracovníci a vyšetřovatelé
Sponzor
Publikace a užitečné odkazy
Obecné publikace
- Dewey M, Zimmermann E, Deissenrieder F, Laule M, Dubel HP, Schlattmann P, Knebel F, Rutsch W, Hamm B. Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation. 2009 Sep 8;120(10):867-75. doi: 10.1161/CIRCULATIONAHA.109.859280. Epub 2009 Aug 24.
- Windecker S, Serruys PW, Wandel S, Buszman P, Trznadel S, Linke A, Lenk K, Ischinger T, Klauss V, Eberli F, Corti R, Wijns W, Morice MC, di Mario C, Davies S, van Geuns RJ, Eerdmans P, van Es GA, Meier B, Juni P. Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial. Lancet. 2008 Sep 27;372(9644):1163-73. doi: 10.1016/S0140-6736(08)61244-1. Epub 2008 Aug 31.
- Colombo A, Latib A. [Treatment of drug-eluting stent restenosis with another drug-eluting stent: do not fail the second time!]. Rev Esp Cardiol. 2008 Nov;61(11):1120-2. No abstract available. Spanish.
- Pasterkamp G, Falk E, Woutman H, Borst C. Techniques characterizing the coronary atherosclerotic plaque: influence on clinical decision making? J Am Coll Cardiol. 2000 Jul;36(1):13-21. doi: 10.1016/s0735-1097(00)00677-x.
- Chau AH, Chan RC, Shishkov M, MacNeill B, Iftimia N, Tearney GJ, Kamm RD, Bouma BE, Kaazempur-Mofrad MR. Mechanical analysis of atherosclerotic plaques based on optical coherence tomography. Ann Biomed Eng. 2004 Nov;32(11):1494-503. doi: 10.1114/b:abme.0000049034.75368.4a.
- Manfrini O, Slucca M, Bugiardini R. [Optical coherence tomography]. G Ital Cardiol (Rome). 2007 Jan;8(1):28-33. Italian.
- Andreini D, Pontone G, Mushtaq S, Pepi M, Bartorelli AL. Multidetector computed tomography coronary angiography for the assessment of coronary in-stent restenosis. Am J Cardiol. 2010 Mar 1;105(5):645-55. doi: 10.1016/j.amjcard.2009.10.046.
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Očekávaný)
Dokončení studie (Očekávaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- W201310
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Ischemická choroba srdeční
-
Region SkaneZápis na pozvánkuSrdeční selhání New York Heart Association (NYHA) třída II | Srdeční selhání New York Heart Association (NYHA) třída IIIŠvédsko
-
Medical University of BialystokInstitute of Cardiology, Warsaw, Poland; Medical University of Lodz; Poznan University... a další spolupracovníciZatím nenabírámeSrdeční selhání, systolické | Srdeční Selhání Se Sníženou Ejekční frakcí | Srdeční selhání New York Heart Association Třída IV | Srdeční selhání New York Heart Association Třída IIIPolsko
-
Novartis PharmaceuticalsDokončenoPacienti, kteří úspěšně dokončili 12měsíční léčebné období základní studie (de Novo Heart Recipients), kteří měli zájem o léčbu EC-MPS
-
University of WashingtonAmerican Heart AssociationDokončenoSrdeční selhání, městnavé | Mitochondriální alterace | Srdeční selhání New York Heart Association Třída IVSpojené státy