The Comparative Study of OCT,Gemstone CT and 320-detector Row Spiral CT for Evaluating Restenosis of Coronary Artery Stent
In-stent restenosis is a major reason of coronary heart disease recurrence .Even in drug eluting stent(DES), Restenosis rate could be up to 10% in diabetes and complex lesions though it was about 3-5% in general. It is particularly important that in-stent restenosis after implantation was early diagnosed and detected. The evaluation of OCT imaging is more accurate for narrow area calculation, more clear for narrow organization structure and more specific for detecting tissue types.It is currently the best way for restenosis histologic diagnosis.But it has many weakness such as the higher cost,an invasive test, expensive instrument, relatively complicated to operate,and etc.In this study, OCT image was regard as the "gold standard" of stent restenosis.
The improvement of spatial resolution of Gemstone CT can effectively improve the imaging quality and the measurement's accuracy of coronary artery stents.The diagnostic value of in-stent restenosis of Gemstone CT is higher than of the 320-detector row spiral CT. To a certain extent, the gemstone CT can replace OCT for examining the in-stent restenosis.
This study will examine the degree of in-stent restenosis by the gemstone CT and the 320-detector row spiral CT and compare the two ways on the basis of the result of OCT.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Tipo de estudio
Inscripción (Anticipado)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Jiangsu
-
Xuzhou, Jiangsu, Porcelana, 221000
- Reclutamiento
- Xuzhou Central Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- Age 20-80, All genders
- Unlimited time of implantation of coronary artery stents
- Myocardial ischemia symptoms such as Chest tightness and/or chest pain in patients after stent implantation
- No clinical symptoms, but myocardial ischemia suggested by other noninvasive tests
- Routine re-testing 9-12 months after stent implantation.
Exclusion Criteria:
- Renal insufficiency (serum creatinine > 120 umol/L)
- Allergy of contrast
- Severe heart failure
- Uncontrollable heart rate or contraindication of taking metoprolol
- Unstable condition
- the ventricular rate beyond 70 beats / min and irregular rhythm after adjusting.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Diagnóstico
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
---|---|
Experimental: Gemstone CT
Gemstone CT :Discovery CT750 HD(high definition) ,GE(General Electric Co.) Healthcare, Milwaukee; CT image for patient with suspected in-stent restenosis which Gemstone CT or 320-detector row spiral CT was assigned randomly to patient
|
Gemstone CT or 320-detector row spiral CT was assigned randomly to patient who was suspected in-stent restenosis.About after 10 days,they would accept the check of OCT which wold be the "gold standard" of in-stent restenosis.
Otros nombres:
|
Comparador activo: 320-detector row spiral CT
320-detector row spiral CT:Aquilion One, Toshiba, Nasu, Japan.
CT image for patient with suspected in-stent restenosis which Gemstone CT or 320-detector row spiral CT was assigned randomly to patient .
|
Gemstone CT or 320-detector row spiral CT was assigned randomly to patient who was suspected in-stent restenosis.About after 10 days,they would accept the check of OCT which wold be the "gold standard" of in-stent restenosis.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Accuracy of detection of in-stent restenosis with the gemstone CT as compared to the 320-detector row spiral CT will be investigated
Periodo de tiempo: On the day in which a patient receives the gemstone CT and the 320-detector row spiral CT, estimated to take 10 mins
|
Masked examiners (CT specialists) will evaluate and compare the degree of in-stent restenosis of the gemstone CT and the 320-detector row spiral CT images for the presence and features of in-stent restenosis.
In this study, OCT image was regard as the "gold standard" of in-stent restenosis.
|
On the day in which a patient receives the gemstone CT and the 320-detector row spiral CT, estimated to take 10 mins
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Radiation burden of the the gemstone CT or the 320-detector row spiral CT and OCT
Periodo de tiempo: one month
|
In a relatively short time,the patient will accept the two checks of CT and OCT(Interval period about 10 days).So,it is necessary to clear the reacts of these patients
|
one month
|
Otras medidas de resultado
Medida de resultado |
Periodo de tiempo |
---|---|
Measurement of the physical characteristics of in-stent restenosis structures seen on OCT
Periodo de tiempo: On the day in which a patient receives the check of OCT
|
On the day in which a patient receives the check of OCT
|
Colaboradores e Investigadores
Patrocinador
Publicaciones y enlaces útiles
Publicaciones Generales
- Dewey M, Zimmermann E, Deissenrieder F, Laule M, Dubel HP, Schlattmann P, Knebel F, Rutsch W, Hamm B. Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation. 2009 Sep 8;120(10):867-75. doi: 10.1161/CIRCULATIONAHA.109.859280. Epub 2009 Aug 24.
- Windecker S, Serruys PW, Wandel S, Buszman P, Trznadel S, Linke A, Lenk K, Ischinger T, Klauss V, Eberli F, Corti R, Wijns W, Morice MC, di Mario C, Davies S, van Geuns RJ, Eerdmans P, van Es GA, Meier B, Juni P. Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial. Lancet. 2008 Sep 27;372(9644):1163-73. doi: 10.1016/S0140-6736(08)61244-1. Epub 2008 Aug 31.
- Colombo A, Latib A. [Treatment of drug-eluting stent restenosis with another drug-eluting stent: do not fail the second time!]. Rev Esp Cardiol. 2008 Nov;61(11):1120-2. No abstract available. Spanish.
- Pasterkamp G, Falk E, Woutman H, Borst C. Techniques characterizing the coronary atherosclerotic plaque: influence on clinical decision making? J Am Coll Cardiol. 2000 Jul;36(1):13-21. doi: 10.1016/s0735-1097(00)00677-x.
- Chau AH, Chan RC, Shishkov M, MacNeill B, Iftimia N, Tearney GJ, Kamm RD, Bouma BE, Kaazempur-Mofrad MR. Mechanical analysis of atherosclerotic plaques based on optical coherence tomography. Ann Biomed Eng. 2004 Nov;32(11):1494-503. doi: 10.1114/b:abme.0000049034.75368.4a.
- Manfrini O, Slucca M, Bugiardini R. [Optical coherence tomography]. G Ital Cardiol (Rome). 2007 Jan;8(1):28-33. Italian.
- Andreini D, Pontone G, Mushtaq S, Pepi M, Bartorelli AL. Multidetector computed tomography coronary angiography for the assessment of coronary in-stent restenosis. Am J Cardiol. 2010 Mar 1;105(5):645-55. doi: 10.1016/j.amjcard.2009.10.046.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Anticipado)
Finalización del estudio (Anticipado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- W201310
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .
Ensayos clínicos sobre Enfermedad coronaria
-
Region SkaneInscripción por invitaciónInsuficiencia cardíaca New York Heart Association (NYHA) Clase II | Insuficiencia cardíaca New York Heart Association (NYHA) Clase IIISuecia
-
Medical University of BialystokInstitute of Cardiology, Warsaw, Poland; Medical University of Lodz; Poznan University... y otros colaboradoresAún no reclutandoInsuficiencia Cardíaca Sistólica | Insuficiencia cardíaca con fracción de eyección reducida | Insuficiencia cardíaca Clase IV de la New York Heart Association | Insuficiencia cardíaca Clase III de la New York Heart AssociationPolonia
-
Novartis PharmaceuticalsTerminadoPacientes que completaron con éxito el período de tratamiento de 12 meses del estudio principal (receptores de Novo Heart) que estaban interesados en recibir tratamiento con EC-MPS
-
University of WashingtonAmerican Heart AssociationTerminadoInsuficiencia cardíaca, congestiva | Alteración mitocondrial | Insuficiencia cardíaca Clase IV de la New York Heart AssociationEstados Unidos