A Double Balloon Endoscopic Platform for ESD
Single Center Prospective Evaluation Utilizing a Double Balloon Accessory Device to Facilitate Complex Endoscopic Polypectomy in Large Intestine
調査の概要
詳細な説明
Endoscopic removal of Complex colon polyps (benign polyps >=2cm) is a technically challenging procedure. Complex benign polyps have a greater chance of becoming cancerous if not removed.
The DiLumen™ Endolumenal Interventional Platform is a non-sterile, single-use, close-fitting sleeve that fits securely over a standard endoscope to stabilize it in the large intestine, and facilitates use of the endoscope for optical visualization, diagnosis, and treatment. The device is indicated to ensure complete positioning of an endoscope in the large intestine and assist with optical visualization, diagnosis, and endoscopic treatment.
The device received 510k clearance on Dec 6, 2016. The study will evaluate performance of the device during routine, scheduled, endoscopic polyp removal for these large polyps.
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
New York
-
Mineola、New York、アメリカ、11501
- Winthrop-NYU Langone
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- Subjects > 18 years of age
- Subjects scheduled for endoscopic removal of suspected complex adenomatous polyps in the large intestine which are sessile or polypoid lesions ≥ 2cm, near the ileocecal valve, dentate line, over a fold, or at a flexure; and or lesions tethered to the colon wall due to previous incomplete resection
- Subjects willing and able to give informed consent
- Subjects who in the opinion of the Principal Investigator have no medical contraindication to endoscopic mucosal resection (EMR) or endoscopic submucosal dissection (ESD)
Exclusion Criteria:
- Subjects with a contraindication to colonoscopy, including but not limited to active colitis, perforation, or stricture.
- Subjects with a history of open or laparoscopic colorectal surgery
- Subjects with a history of Inflammatory Bowel Disease (IBD)
- Subjects with a suspected malignancy on polyp assessment
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:コホート
- 時間の展望:見込みのある
コホートと介入
グループ/コホート |
介入・治療 |
|---|---|
|
Endoscopic procedure
A double balloon endoscopic platform will be used during an ESD procedure
|
A DBA platform will be use din this registry study to facilitate ESD
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Ability to remove the complex polyp endoscopically
時間枠:Duration of Procedure
|
Was the lesion(s) able to be removed using the DiLumen Endolumenal Interventional Platform Device [Yes/No]
|
Duration of Procedure
|
|
Time taken for lesion removal
時間枠:Intervention start time until Lesion removal
|
Time for lesion(s) removal with the double balloon device after intervention begins
|
Intervention start time until Lesion removal
|
|
Device or Procedural Adverse Events
時間枠:Up to 72 hours
|
Colon perforation, colon mucosal injury, excess bleeding will be recorded
|
Up to 72 hours
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Stavros Stavropoulos, MD、Winthrop-NYU Langone Mineola, NY
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。