Programming Cochlear Implant With Artificial Intelligence (CI_AI)

This thesis project proposes to investigate the "state of the art" of the programming of the cochlear implant. In the center of audiophonologie Brussels, the classic 'manual programming' has been in use over 20 years and also the new way 'Artificial Intelligence programming'. The investigators want to compare, objectify, and control this new mode of programming.

The study is planned over 4 years, in order to test, randomized, 15 subjects with manual programming and 15 other subjects with Artificial Intelligence programming. To test the performance of Cochlear Implant patients, audiological, language auditory perception and questionnaire tests will be presented.

This research aims to determine the contribution and results of Artificial Intelligence programming.

調査の概要

研究の種類

介入

入学 (予想される)

30

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • unilateral cochlear implant
  • post-lingual hearing loss
  • a good command of French.

Exclusion Criteria:

  • non deaf
  • bilateral cochlear implant
  • deaf without cochlear implant

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:クロスオーバー割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Manual fitting
The patient is receiving the classical treatment : 10 sessions of 1 hour during one year where the clinician programs manually the Cochlear implant.
The Clinician test the 22 electrodes so that the patient is able to hear the language
実験的:Artificial Intelligence
The patient is receiving the new treatment : 4 sessions of 1 hour during one year where the clinician programs the Cochlear implant with the FOX (Fitting to Outcome eXpert) software using artificial intelligence.
The Clinician test the 22 electrodes so that the patient is able to hear the language

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Evaluate Fox software efficiency
時間枠:1 year

Evaluate Fox software efficiency for the programming of Cochlear implants used to facilitate hearing of deaf patients. This research aims to determine the contribution (time, results,…) of Artificial intelligence to program cochlear implants. The investigator will compare the results of hearing tests of newly programmed patients with FOX to those of newly programmed patients with a manual fitting.

The outcomes used by software FOX are pure tone audiometry thresholds from 250 to 6000Hz, speech audiometry scores at 40, 55, 70 and 85 dB SPL, spectral discrimination scores using an oddity test in which 2 speech sounds are presented and where the aim is to react to the odd speech sound (Govaerts et al. 2006), and loudness growth curves determined with narrow band noises centered at 250, 1000 and 4000 Hz using an A§E® test battery (Meeuws et al., 2017).

1 year

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2017年9月4日

一次修了 (予想される)

2020年9月1日

研究の完了 (予想される)

2021年9月1日

試験登録日

最初に提出

2018年10月4日

QC基準を満たした最初の提出物

2018年10月8日

最初の投稿 (実際)

2018年10月9日

学習記録の更新

投稿された最後の更新 (実際)

2018年10月9日

QC基準を満たした最後の更新が送信されました

2018年10月8日

最終確認日

2018年10月1日

詳しくは

本研究に関する用語

キーワード

その他の研究ID番号

  • 2017/04SEP/427
  • 2017/13OCT/480 (その他の識別子:CEHF of Cliniques Universitaires Saint Luc)

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。