このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

LBBAP vs. CS Pacing for CRT in Permanent Atrial Fibrillation and Heart Failure (SYNC-AF) (SYNC-AF)

2026年4月23日 更新者:Yonsei University

Left Bundle Branch Area Pacing Versus Coronary Sinus Pacing for Cardiac Resynchronization Therapy for Patients With Permanent Atrial Fibrillation and Heart Failure: The SYNC-AF Trial

This is a prospective, multicenter, randomized controlled trial comparing Left Bundle Branch Area Pacing (LBBAP)-based cardiac resynchronization therapy (CRT) with conventional coronary sinus (CS) lead-based CRT in patients with permanent atrial fibrillation (AF) and heart failure (HF) who meet indications for CRT device implantation.

Atrial fibrillation and heart failure frequently coexist, and both rapid heart rate and its irregularity contribute to worsening cardiac function. Atrioventricular junction (AVJ) ablation combined with CRT (biventricular pacing) has been established as an effective strategy for rate control and cardiac resynchronization in this population, supported by Class I recommendation in the 2021 ESC guidelines. However, conventional biventricular CRT via the CS lead can induce artificial electrical dyssynchrony, particularly in patients with a narrow QRS complex, potentially limiting its benefit.

Conduction system pacing (CSP), including LBBAP, has emerged as a physiologic alternative that directly stimulates the native conduction system, preserving synchronous ventricular activation. Recent evidence (ALTERNATIVE-AF trial) suggests CSP may be superior to biventricular CRT in permanent AF patients undergoing AVJ ablation. However, no randomized controlled trial has directly compared LBBAP-based CRT with CS lead-based CRT in this specific population.

The SYNC-AF trial will randomize 44 patients (22 per arm) to either LBBAP or CS pacing for CRT. The primary endpoint is change in left ventricular ejection fraction (LVEF) at 12 months as assessed by echocardiography in a blinded core laboratory. Secondary endpoints include changes in QRS duration, major adverse clinical events, device/procedure-related complications, and ventricular arrhythmia burden.

調査の概要

詳細な説明

ECHOCARDIOGRAPHIC CORE LAB:

All echocardiographic assessments (LVEF, LVESV, LVEDV, etc.) are performed and interpreted by a blinded independent core laboratory at Severance Hospital to ensure objective and consistent measurement.

FOLLOW-UP SCHEDULE:

Screening (implant day) → Visit 1 (2 weeks-1 month) → Visit 2 (3 months ±3 months) → Visit 3 (6 months ±3 months) → Visit 4 (12 months ±3 months).

STATISTICAL ANALYSIS:

Primary analysis follows the Intention-To-Treat (ITT) principle. Per-Protocol (PP) analysis will be performed as sensitivity analysis. The primary endpoint (LVEF change at 12 months) will be compared using Student's t-test or Wilcoxon rank-sum test. Time-to-event analyses will use Kaplan-Meier survival curves with log-rank test and Cox proportional hazards model.

SAMPLE SIZE:

44 patients total (22 per arm). Based on the assumption of an absolute 10% greater improvement in LVEF with LBBAP-CRT vs. BiV-CRT, with 80% power and 5% two-sided alpha, with 10% dropout allowance.

PARTICIPATING CENTERS:

Multiple centers in the Republic of Korea (at least 4 centers), led by Severance Hospital, Yonsei University College of Medicine.

研究の種類

介入

入学 (推定)

44

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

  • 名前:Tae-Hoon Kim, Professor
  • 電話番号:+82-2-2228-8467
  • メール:thkimcardio@yuhs.ac

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

説明

Inclusion Criteria:

  1. Age ≥19 years
  2. Indication for CRT (CRT-P or CRT-D) device implantation per current guidelines
  3. Permanent atrial fibrillation (with or without planned AVJ ablation)
  4. Ability to understand the purpose of the study and provide written informed consent

Exclusion Criteria:

  1. Prosthetic tricuspid valve
  2. Prior myocardial infarction involving the interventricular septal area
  3. Life expectancy less than 12 months
  4. Unable to comply with planned 12-month follow-up for any reason
  5. Pregnancy
  6. History of heart transplantation
  7. Persistent left superior vena cava (PLSVC)

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:独身

武器と介入

参加者グループ / アーム
介入・治療
実験的:LBBAP Group
Participants undergo CRT device implantation (CRT-P or CRT-D) with Left Bundle Branch Area Pacing (LBBAP) as the left ventricular lead strategy. LBBAP is attempted first; if not feasible, crossover to CS lead is permitted. AVJ ablation is performed per clinical indication.
CRT device (CRT-P or CRT-D) implantation using LBBAP as the left ventricular pacing lead. A pacing lead is advanced through the interventricular septum to achieve left bundle branch area capture, confirmed by pacing parameters and electrocardiographic criteria (RBBB-like pattern with short R-peak latency in V5/V6). RV lead is implanted in standard fashion. AVJ ablation may be performed per clinical indication.
アクティブコンパレータ:CS Pacing Group
Participants undergo CRT device implantation (CRT-P or CRT-D) with conventional Coronary Sinus (CS) lead-based pacing as the left ventricular lead strategy. AVJ ablation is performed per clinical indication.
CRT device (CRT-P or CRT-D) implantation using a conventional coronary sinus (CS) lead as the left ventricular pacing lead. The CS lead is advanced via the coronary sinus into a lateral or posterolateral cardiac vein to achieve biventricular pacing. RV lead is implanted in standard fashion. AVJ ablation may be performed per clinical indication.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Change from Baseline Left Ventricular Ejection Fraction (LVEF) at 12 Months
時間枠:Baseline (at the time of device implantation) and 12 months post-implantation
Change in left ventricular ejection fraction (LVEF) from baseline to 12 months post-implantation, as measured by transthoracic echocardiography performed and interpreted by a blinded independent central core laboratory. LVEF is assessed using the biplane Simpson method.
Baseline (at the time of device implantation) and 12 months post-implantation

二次結果の測定

結果測定
メジャーの説明
時間枠
Proportion of patients with absolute LVEF increase ≥5% at 12 months
時間枠:12 months post-implantation
Echocardiographic CRT response defined as absolute improvement in LVEF of ≥5% or ≥10% from baseline at 12 months, assessed by blinded core lab.
12 months post-implantation
Proportion of patients with absolute LVEF increase ≥10% at 12 months
時間枠:12 months post-implantation
Echocardiographic CRT response defined as absolute improvement in LVEF of ≥5% or ≥10% from baseline at 12 months, assessed by blinded core lab.
12 months post-implantation
Change in QRS Duration From Baseline
時間枠:Immediately post-implant and at 12 months
QRS duration measured from surface ECG in milliseconds.
Immediately post-implant and at 12 months
Time to First Treated Ventricular Arrhythmia
時間枠:Up to 12 months
Time from randomization to first detection of treated ventricular arrhythmia (VT/VF) recorded by the implanted device within 12 months.
Up to 12 months
Composite of All-Cause Death and Heart Failure Hospitalization
時間枠:Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
All-cause mortality
時間枠:Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
Heart failure hospitalization
時間枠:Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
Cardiovascular death
時間枠:Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
Immediate procedural success rate of LBBAP lead implantation
時間枠:Immediately after the implantation procedure
Successful LBBAP lead placement defined by achievement of left bundle branch capture with acceptable pacing threshold (≤1.5V/0.5ms), impedance (300-1200Ω), and electrocardiographic criteria (RBBB pattern, short R-peak latency in V5/V6).
Immediately after the implantation procedure
Lead capture loss rate at 12 months
時間枠:12 months post-implantation
Loss of left bundle branch capture or inability to maintain pacing threshold <2.5V/0.5ms at 12 months.
12 months post-implantation
Composite Rate of Worsening Heart Failure by Echocardiographic Criteria
時間枠:Up to 12 months
Composite endpoint defined as ≥5% absolute decrease in LVEF from baseline or ≥15% increase in LVESV from baseline during follow-up.
Up to 12 months
Device and Procedure-Related Complications
時間枠:Up to 12 months (device/procedure-related complications within 7 days for acute; up to 12 months for chronic)
All device/procedure-related complications and reinterventions occurring up to 12 months, adjudicated by an independent events committee.
Up to 12 months (device/procedure-related complications within 7 days for acute; up to 12 months for chronic)
Reintervention Rate
時間枠:Up to 12 months
All device/procedure-related complications and reinterventions occurring up to 12 months, adjudicated by an independent events committee.
Up to 12 months

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年6月30日

一次修了 (推定)

2029年6月30日

研究の完了 (推定)

2029年12月31日

試験登録日

最初に提出

2026年4月23日

QC基準を満たした最初の提出物

2026年4月23日

最初の投稿 (実際)

2026年5月1日

学習記録の更新

投稿された最後の更新 (実際)

2026年5月1日

QC基準を満たした最後の更新が送信されました

2026年4月23日

最終確認日

2026年4月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する