Denna sida har översatts automatiskt och översättningens korrekthet kan inte garanteras. Vänligen se engelsk version för en källtext.

LBBAP vs. CS Pacing for CRT in Permanent Atrial Fibrillation and Heart Failure (SYNC-AF) (SYNC-AF)

23 april 2026 uppdaterad av: Yonsei University

Left Bundle Branch Area Pacing Versus Coronary Sinus Pacing for Cardiac Resynchronization Therapy for Patients With Permanent Atrial Fibrillation and Heart Failure: The SYNC-AF Trial

This is a prospective, multicenter, randomized controlled trial comparing Left Bundle Branch Area Pacing (LBBAP)-based cardiac resynchronization therapy (CRT) with conventional coronary sinus (CS) lead-based CRT in patients with permanent atrial fibrillation (AF) and heart failure (HF) who meet indications for CRT device implantation.

Atrial fibrillation and heart failure frequently coexist, and both rapid heart rate and its irregularity contribute to worsening cardiac function. Atrioventricular junction (AVJ) ablation combined with CRT (biventricular pacing) has been established as an effective strategy for rate control and cardiac resynchronization in this population, supported by Class I recommendation in the 2021 ESC guidelines. However, conventional biventricular CRT via the CS lead can induce artificial electrical dyssynchrony, particularly in patients with a narrow QRS complex, potentially limiting its benefit.

Conduction system pacing (CSP), including LBBAP, has emerged as a physiologic alternative that directly stimulates the native conduction system, preserving synchronous ventricular activation. Recent evidence (ALTERNATIVE-AF trial) suggests CSP may be superior to biventricular CRT in permanent AF patients undergoing AVJ ablation. However, no randomized controlled trial has directly compared LBBAP-based CRT with CS lead-based CRT in this specific population.

The SYNC-AF trial will randomize 44 patients (22 per arm) to either LBBAP or CS pacing for CRT. The primary endpoint is change in left ventricular ejection fraction (LVEF) at 12 months as assessed by echocardiography in a blinded core laboratory. Secondary endpoints include changes in QRS duration, major adverse clinical events, device/procedure-related complications, and ventricular arrhythmia burden.

Studieöversikt

Detaljerad beskrivning

ECHOCARDIOGRAPHIC CORE LAB:

All echocardiographic assessments (LVEF, LVESV, LVEDV, etc.) are performed and interpreted by a blinded independent core laboratory at Severance Hospital to ensure objective and consistent measurement.

FOLLOW-UP SCHEDULE:

Screening (implant day) → Visit 1 (2 weeks-1 month) → Visit 2 (3 months ±3 months) → Visit 3 (6 months ±3 months) → Visit 4 (12 months ±3 months).

STATISTICAL ANALYSIS:

Primary analysis follows the Intention-To-Treat (ITT) principle. Per-Protocol (PP) analysis will be performed as sensitivity analysis. The primary endpoint (LVEF change at 12 months) will be compared using Student's t-test or Wilcoxon rank-sum test. Time-to-event analyses will use Kaplan-Meier survival curves with log-rank test and Cox proportional hazards model.

SAMPLE SIZE:

44 patients total (22 per arm). Based on the assumption of an absolute 10% greater improvement in LVEF with LBBAP-CRT vs. BiV-CRT, with 80% power and 5% two-sided alpha, with 10% dropout allowance.

PARTICIPATING CENTERS:

Multiple centers in the Republic of Korea (at least 4 centers), led by Severance Hospital, Yonsei University College of Medicine.

Studietyp

Interventionell

Inskrivning (Beräknad)

44

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studiekontakt

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

  • Vuxen
  • Äldre vuxen

Tar emot friska volontärer

Nej

Beskrivning

Inclusion Criteria:

  1. Age ≥19 years
  2. Indication for CRT (CRT-P or CRT-D) device implantation per current guidelines
  3. Permanent atrial fibrillation (with or without planned AVJ ablation)
  4. Ability to understand the purpose of the study and provide written informed consent

Exclusion Criteria:

  1. Prosthetic tricuspid valve
  2. Prior myocardial infarction involving the interventricular septal area
  3. Life expectancy less than 12 months
  4. Unable to comply with planned 12-month follow-up for any reason
  5. Pregnancy
  6. History of heart transplantation
  7. Persistent left superior vena cava (PLSVC)

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Behandling
  • Tilldelning: Randomiserad
  • Interventionsmodell: Parallellt uppdrag
  • Maskning: Enda

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Experimentell: LBBAP Group
Participants undergo CRT device implantation (CRT-P or CRT-D) with Left Bundle Branch Area Pacing (LBBAP) as the left ventricular lead strategy. LBBAP is attempted first; if not feasible, crossover to CS lead is permitted. AVJ ablation is performed per clinical indication.
CRT device (CRT-P or CRT-D) implantation using LBBAP as the left ventricular pacing lead. A pacing lead is advanced through the interventricular septum to achieve left bundle branch area capture, confirmed by pacing parameters and electrocardiographic criteria (RBBB-like pattern with short R-peak latency in V5/V6). RV lead is implanted in standard fashion. AVJ ablation may be performed per clinical indication.
Aktiv komparator: CS Pacing Group
Participants undergo CRT device implantation (CRT-P or CRT-D) with conventional Coronary Sinus (CS) lead-based pacing as the left ventricular lead strategy. AVJ ablation is performed per clinical indication.
CRT device (CRT-P or CRT-D) implantation using a conventional coronary sinus (CS) lead as the left ventricular pacing lead. The CS lead is advanced via the coronary sinus into a lateral or posterolateral cardiac vein to achieve biventricular pacing. RV lead is implanted in standard fashion. AVJ ablation may be performed per clinical indication.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Change from Baseline Left Ventricular Ejection Fraction (LVEF) at 12 Months
Tidsram: Baseline (at the time of device implantation) and 12 months post-implantation
Change in left ventricular ejection fraction (LVEF) from baseline to 12 months post-implantation, as measured by transthoracic echocardiography performed and interpreted by a blinded independent central core laboratory. LVEF is assessed using the biplane Simpson method.
Baseline (at the time of device implantation) and 12 months post-implantation

Sekundära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Proportion of patients with absolute LVEF increase ≥5% at 12 months
Tidsram: 12 months post-implantation
Echocardiographic CRT response defined as absolute improvement in LVEF of ≥5% or ≥10% from baseline at 12 months, assessed by blinded core lab.
12 months post-implantation
Proportion of patients with absolute LVEF increase ≥10% at 12 months
Tidsram: 12 months post-implantation
Echocardiographic CRT response defined as absolute improvement in LVEF of ≥5% or ≥10% from baseline at 12 months, assessed by blinded core lab.
12 months post-implantation
Change in QRS Duration From Baseline
Tidsram: Immediately post-implant and at 12 months
QRS duration measured from surface ECG in milliseconds.
Immediately post-implant and at 12 months
Time to First Treated Ventricular Arrhythmia
Tidsram: Up to 12 months
Time from randomization to first detection of treated ventricular arrhythmia (VT/VF) recorded by the implanted device within 12 months.
Up to 12 months
Composite of All-Cause Death and Heart Failure Hospitalization
Tidsram: Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
All-cause mortality
Tidsram: Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
Heart failure hospitalization
Tidsram: Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
Cardiovascular death
Tidsram: Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
Immediate procedural success rate of LBBAP lead implantation
Tidsram: Immediately after the implantation procedure
Successful LBBAP lead placement defined by achievement of left bundle branch capture with acceptable pacing threshold (≤1.5V/0.5ms), impedance (300-1200Ω), and electrocardiographic criteria (RBBB pattern, short R-peak latency in V5/V6).
Immediately after the implantation procedure
Lead capture loss rate at 12 months
Tidsram: 12 months post-implantation
Loss of left bundle branch capture or inability to maintain pacing threshold <2.5V/0.5ms at 12 months.
12 months post-implantation
Composite Rate of Worsening Heart Failure by Echocardiographic Criteria
Tidsram: Up to 12 months
Composite endpoint defined as ≥5% absolute decrease in LVEF from baseline or ≥15% increase in LVESV from baseline during follow-up.
Up to 12 months
Device and Procedure-Related Complications
Tidsram: Up to 12 months (device/procedure-related complications within 7 days for acute; up to 12 months for chronic)
All device/procedure-related complications and reinterventions occurring up to 12 months, adjudicated by an independent events committee.
Up to 12 months (device/procedure-related complications within 7 days for acute; up to 12 months for chronic)
Reintervention Rate
Tidsram: Up to 12 months
All device/procedure-related complications and reinterventions occurring up to 12 months, adjudicated by an independent events committee.
Up to 12 months

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Beräknad)

30 juni 2026

Primärt slutförande (Beräknad)

30 juni 2029

Avslutad studie (Beräknad)

31 december 2029

Studieregistreringsdatum

Först inskickad

23 april 2026

Först inskickad som uppfyllde QC-kriterierna

23 april 2026

Första postat (Faktisk)

1 maj 2026

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

1 maj 2026

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

23 april 2026

Senast verifierad

1 april 2026

Mer information

Termer relaterade till denna studie

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

NEJ

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .

Prenumerera