Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

LBBAP vs. CS Pacing for CRT in Permanent Atrial Fibrillation and Heart Failure (SYNC-AF) (SYNC-AF)

23 апреля 2026 г. обновлено: Yonsei University

Left Bundle Branch Area Pacing Versus Coronary Sinus Pacing for Cardiac Resynchronization Therapy for Patients With Permanent Atrial Fibrillation and Heart Failure: The SYNC-AF Trial

This is a prospective, multicenter, randomized controlled trial comparing Left Bundle Branch Area Pacing (LBBAP)-based cardiac resynchronization therapy (CRT) with conventional coronary sinus (CS) lead-based CRT in patients with permanent atrial fibrillation (AF) and heart failure (HF) who meet indications for CRT device implantation.

Atrial fibrillation and heart failure frequently coexist, and both rapid heart rate and its irregularity contribute to worsening cardiac function. Atrioventricular junction (AVJ) ablation combined with CRT (biventricular pacing) has been established as an effective strategy for rate control and cardiac resynchronization in this population, supported by Class I recommendation in the 2021 ESC guidelines. However, conventional biventricular CRT via the CS lead can induce artificial electrical dyssynchrony, particularly in patients with a narrow QRS complex, potentially limiting its benefit.

Conduction system pacing (CSP), including LBBAP, has emerged as a physiologic alternative that directly stimulates the native conduction system, preserving synchronous ventricular activation. Recent evidence (ALTERNATIVE-AF trial) suggests CSP may be superior to biventricular CRT in permanent AF patients undergoing AVJ ablation. However, no randomized controlled trial has directly compared LBBAP-based CRT with CS lead-based CRT in this specific population.

The SYNC-AF trial will randomize 44 patients (22 per arm) to either LBBAP or CS pacing for CRT. The primary endpoint is change in left ventricular ejection fraction (LVEF) at 12 months as assessed by echocardiography in a blinded core laboratory. Secondary endpoints include changes in QRS duration, major adverse clinical events, device/procedure-related complications, and ventricular arrhythmia burden.

Обзор исследования

Подробное описание

ECHOCARDIOGRAPHIC CORE LAB:

All echocardiographic assessments (LVEF, LVESV, LVEDV, etc.) are performed and interpreted by a blinded independent core laboratory at Severance Hospital to ensure objective and consistent measurement.

FOLLOW-UP SCHEDULE:

Screening (implant day) → Visit 1 (2 weeks-1 month) → Visit 2 (3 months ±3 months) → Visit 3 (6 months ±3 months) → Visit 4 (12 months ±3 months).

STATISTICAL ANALYSIS:

Primary analysis follows the Intention-To-Treat (ITT) principle. Per-Protocol (PP) analysis will be performed as sensitivity analysis. The primary endpoint (LVEF change at 12 months) will be compared using Student's t-test or Wilcoxon rank-sum test. Time-to-event analyses will use Kaplan-Meier survival curves with log-rank test and Cox proportional hazards model.

SAMPLE SIZE:

44 patients total (22 per arm). Based on the assumption of an absolute 10% greater improvement in LVEF with LBBAP-CRT vs. BiV-CRT, with 80% power and 5% two-sided alpha, with 10% dropout allowance.

PARTICIPATING CENTERS:

Multiple centers in the Republic of Korea (at least 4 centers), led by Severance Hospital, Yonsei University College of Medicine.

Тип исследования

Интервенционный

Регистрация (Оцененный)

44

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Контакты исследования

  • Имя: Tae-Hoon Kim, Professor
  • Номер телефона: +82-2-2228-8467
  • Электронная почта: thkimcardio@yuhs.ac

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

  • Взрослый
  • Пожилой взрослый

Принимает здоровых добровольцев

Нет

Описание

Inclusion Criteria:

  1. Age ≥19 years
  2. Indication for CRT (CRT-P or CRT-D) device implantation per current guidelines
  3. Permanent atrial fibrillation (with or without planned AVJ ablation)
  4. Ability to understand the purpose of the study and provide written informed consent

Exclusion Criteria:

  1. Prosthetic tricuspid valve
  2. Prior myocardial infarction involving the interventricular septal area
  3. Life expectancy less than 12 months
  4. Unable to comply with planned 12-month follow-up for any reason
  5. Pregnancy
  6. History of heart transplantation
  7. Persistent left superior vena cava (PLSVC)

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Уход
  • Распределение: Рандомизированный
  • Интервенционная модель: Параллельное назначение
  • Маскировка: Одинокий

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: LBBAP Group
Participants undergo CRT device implantation (CRT-P or CRT-D) with Left Bundle Branch Area Pacing (LBBAP) as the left ventricular lead strategy. LBBAP is attempted first; if not feasible, crossover to CS lead is permitted. AVJ ablation is performed per clinical indication.
CRT device (CRT-P or CRT-D) implantation using LBBAP as the left ventricular pacing lead. A pacing lead is advanced through the interventricular septum to achieve left bundle branch area capture, confirmed by pacing parameters and electrocardiographic criteria (RBBB-like pattern with short R-peak latency in V5/V6). RV lead is implanted in standard fashion. AVJ ablation may be performed per clinical indication.
Активный компаратор: CS Pacing Group
Participants undergo CRT device implantation (CRT-P or CRT-D) with conventional Coronary Sinus (CS) lead-based pacing as the left ventricular lead strategy. AVJ ablation is performed per clinical indication.
CRT device (CRT-P or CRT-D) implantation using a conventional coronary sinus (CS) lead as the left ventricular pacing lead. The CS lead is advanced via the coronary sinus into a lateral or posterolateral cardiac vein to achieve biventricular pacing. RV lead is implanted in standard fashion. AVJ ablation may be performed per clinical indication.

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Change from Baseline Left Ventricular Ejection Fraction (LVEF) at 12 Months
Временное ограничение: Baseline (at the time of device implantation) and 12 months post-implantation
Change in left ventricular ejection fraction (LVEF) from baseline to 12 months post-implantation, as measured by transthoracic echocardiography performed and interpreted by a blinded independent central core laboratory. LVEF is assessed using the biplane Simpson method.
Baseline (at the time of device implantation) and 12 months post-implantation

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Proportion of patients with absolute LVEF increase ≥5% at 12 months
Временное ограничение: 12 months post-implantation
Echocardiographic CRT response defined as absolute improvement in LVEF of ≥5% or ≥10% from baseline at 12 months, assessed by blinded core lab.
12 months post-implantation
Proportion of patients with absolute LVEF increase ≥10% at 12 months
Временное ограничение: 12 months post-implantation
Echocardiographic CRT response defined as absolute improvement in LVEF of ≥5% or ≥10% from baseline at 12 months, assessed by blinded core lab.
12 months post-implantation
Change in QRS Duration From Baseline
Временное ограничение: Immediately post-implant and at 12 months
QRS duration measured from surface ECG in milliseconds.
Immediately post-implant and at 12 months
Time to First Treated Ventricular Arrhythmia
Временное ограничение: Up to 12 months
Time from randomization to first detection of treated ventricular arrhythmia (VT/VF) recorded by the implanted device within 12 months.
Up to 12 months
Composite of All-Cause Death and Heart Failure Hospitalization
Временное ограничение: Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
All-cause mortality
Временное ограничение: Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
Heart failure hospitalization
Временное ограничение: Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
Cardiovascular death
Временное ограничение: Up to 12 months (first occurrence)
Clinical events adjudicated by an independent committee. Heart failure hospitalization defined as unplanned outpatient/ED visit or inpatient admission with HF signs/symptoms requiring intravenous therapy.
Up to 12 months (first occurrence)
Immediate procedural success rate of LBBAP lead implantation
Временное ограничение: Immediately after the implantation procedure
Successful LBBAP lead placement defined by achievement of left bundle branch capture with acceptable pacing threshold (≤1.5V/0.5ms), impedance (300-1200Ω), and electrocardiographic criteria (RBBB pattern, short R-peak latency in V5/V6).
Immediately after the implantation procedure
Lead capture loss rate at 12 months
Временное ограничение: 12 months post-implantation
Loss of left bundle branch capture or inability to maintain pacing threshold <2.5V/0.5ms at 12 months.
12 months post-implantation
Composite Rate of Worsening Heart Failure by Echocardiographic Criteria
Временное ограничение: Up to 12 months
Composite endpoint defined as ≥5% absolute decrease in LVEF from baseline or ≥15% increase in LVESV from baseline during follow-up.
Up to 12 months
Device and Procedure-Related Complications
Временное ограничение: Up to 12 months (device/procedure-related complications within 7 days for acute; up to 12 months for chronic)
All device/procedure-related complications and reinterventions occurring up to 12 months, adjudicated by an independent events committee.
Up to 12 months (device/procedure-related complications within 7 days for acute; up to 12 months for chronic)
Reintervention Rate
Временное ограничение: Up to 12 months
All device/procedure-related complications and reinterventions occurring up to 12 months, adjudicated by an independent events committee.
Up to 12 months

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Оцененный)

30 июня 2026 г.

Первичное завершение (Оцененный)

30 июня 2029 г.

Завершение исследования (Оцененный)

31 декабря 2029 г.

Даты регистрации исследования

Первый отправленный

23 апреля 2026 г.

Впервые представлено, что соответствует критериям контроля качества

23 апреля 2026 г.

Первый опубликованный (Действительный)

1 мая 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

1 мая 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

23 апреля 2026 г.

Последняя проверка

1 апреля 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕТ

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться