Assessment Polyether Ether Ketone (PEEK) Custom Made Plates Versuscustom Made Titanium Plates in Treatment of Mandibular Body Fractures
Radiographic Assessment of Accuracy of Computer-assisted Polyether Ether Ketone (PEEK) Custom Made Plates Versus Computer-assisted Custom Made Titanium Plates in Treatment of Mandibular Body Fractures (A Randomized Clinical Trial)
The design of the custom made Plates is customized to meet the individual needs of each patient and surgeon. By selecting plate design features, surgeons can customize the plate to create a patient specific solution. The Patient Specific Plates are manufactured to the planned patient anatomy, eliminating the time needed for intraoperative adaption and creating a stronger plate with a lower overall profile.
But Custom made plates were made in many materials such as titanium, Vitalium, PEEK, etc In this study we will compare the PEEK one with the titanium one to know which one is better in all aspects and if the PEEK one can overcome the shortcoming of the titanium one or not.
調査の概要
詳細な説明
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Cairo Governorate
-
Giza、Cairo Governorate、エジプト、12515
- Cairo University
-
-
参加基準
適格基準
就学可能な年齢
- 子
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
Patients with at least a unilateral body fracture indicated for Open reduction internal fixation.
--Dentate adult patients.
- All ages and both sexes were included in this study.
Exclusion Criteria:
- Patients with systemic disease (may affect normal healing).
- Patients with old and/or mal united fractures (affect accuracy of re-reduced the fractured segments).
- Patients whom cannot tolerate follow up intervals (affect accuracy of study results).
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:PEEK
computer-assisted Polyether ether ketone (PEEK) custom made plates
|
computer-assisted Polyether ether ketone (PEEK) custom made plates in mandibular body fractures management
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
radiographic assessment of accuracy in mandibular body fractures management
時間枠:3 months
|
using Mimics software
|
3 months
|
協力者と研究者
スポンサー
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- cairo uniiversity
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。