Assessment Polyether Ether Ketone (PEEK) Custom Made Plates Versuscustom Made Titanium Plates in Treatment of Mandibular Body Fractures
Radiographic Assessment of Accuracy of Computer-assisted Polyether Ether Ketone (PEEK) Custom Made Plates Versus Computer-assisted Custom Made Titanium Plates in Treatment of Mandibular Body Fractures (A Randomized Clinical Trial)
The design of the custom made Plates is customized to meet the individual needs of each patient and surgeon. By selecting plate design features, surgeons can customize the plate to create a patient specific solution. The Patient Specific Plates are manufactured to the planned patient anatomy, eliminating the time needed for intraoperative adaption and creating a stronger plate with a lower overall profile.
But Custom made plates were made in many materials such as titanium, Vitalium, PEEK, etc In this study we will compare the PEEK one with the titanium one to know which one is better in all aspects and if the PEEK one can overcome the shortcoming of the titanium one or not.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
Cairo Governorate
-
Giza, Cairo Governorate, Egypte, 12515
- Cairo University
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
Patients with at least a unilateral body fracture indicated for Open reduction internal fixation.
--Dentate adult patients.
- All ages and both sexes were included in this study.
Exclusion Criteria:
- Patients with systemic disease (may affect normal healing).
- Patients with old and/or mal united fractures (affect accuracy of re-reduced the fractured segments).
- Patients whom cannot tolerate follow up intervals (affect accuracy of study results).
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: PEEK
computer-assisted Polyether ether ketone (PEEK) custom made plates
|
computer-assisted Polyether ether ketone (PEEK) custom made plates in mandibular body fractures management
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
radiographic assessment of accuracy in mandibular body fractures management
Délai: 3 months
|
using Mimics software
|
3 months
|
Collaborateurs et enquêteurs
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- cairo uniiversity
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .