Wireless MicroPremVitals Button Sensor in the NICU

Miniaturized Vital Sign Monitoring for Preterm Infants in the Neonatal Intensive Care Unit

A wireless and miniaturized vital sign (ECG, SpO2, Skin Temperature) sensor system, MicroPremVitals Button Sensors was developed by the Dr. John Rogers Laboratory (QSIB- Northwestern University, Chicago, USA) to facilitate vital sign monitoring in extremely preterm neonates.

調査の概要

詳細な説明

Building on prior collaborative work between the Smart Hospital Project and the Dr. John Rogers Laboratory (QSIB- Northwestern University, Chicago, USA) in skin-integrated, soft, flexible electronics for premature infants, these button-sized sensors are designed to provide continuous ECG, oxygen saturation (SpO₂), and skin temperature monitoring without the bulky wires and large adhesives that impact the most fragile infants. By miniaturizing the hardware and tailoring form factor, weight, and interface materials for fragile neonatal skin, the system aims to extend wireless, clinical-grade monitoring down to the smallest, sickest babies.

In the NICU, the possible use of wireless sensors has received positive feedback from parents and HCPs. Overall, the perception is that eliminating the wires and cables will facilitate sensors application and monitoring, improve patient comfort, and skin-to-skin contact between infants and parents.

This proposal aims to:

  1. Investigate the feasibility, safety, and accuracy of the Wireless MicroPremVitals Button Sensors monitoring system specifically developed for use in extremely preterm neonates.
  2. Assess parents and HCPs perspectives on standard and wireless vital sign monitoring systems in extremely preterm infants.

研究の種類

介入

入学 (推定)

10

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究場所

    • Quebec
      • Montreal、Quebec、カナダ、H4A 3H9
        • 募集
        • Montreal Children's Hospital
        • コンタクト:
        • 主任研究者:
          • Guilherme Sant'Anna, MD, PhD

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 子
  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

説明

Inclusion Criteria:

  • Infants admitted to the NICU with a gestational age of ≥ 22+0 weeks and ≤ 29+6 weeks at birth,
  • AND >72h of age at time of study,
  • AND clinically stable,
  • AND with the Neonatal Nurse Practitioner (i.e., NNP) and Healthcare Team in agreement for the patient to participate in the study.

Exclusion Criteria:

  • Infants with a skin abnormality that would potentially increase the risk of injury,
  • patient too unstable or family experiencing too much stress as determined by an attending physician or bedside care team to not be approached for recruitment.
  • Infants admitted to the NICU with a gestational age of < 22+0 weeks or > 29+6 weeks at birth,
  • and/or ≤ 72h of age at time of study,
  • and/or not meeting all requirements of clinical stability,
  • and/or with the Neonatal Nurse Practitioner (i.e., NNP)/Healthcare Team in disagreement for the patient to participate in the study.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:デバイスの実現可能性
  • 割り当て:非ランダム化
  • 介入モデル:並列代入
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Extremely Preterm Infant

The Wireless MicroPremVitals Button Sensor System consists of three (3) sensors: a chest unit, a forehead unit, and a limb unit.

In this study, the MicroPremVitals Button forehead sensor will be mounted on the cerebral area of neonates at the level of the forehead. The chest unit will be mounted on the chest, between the nipples, or slightly below the nipple-line as placement allows. The limb unit will be mounted on the outer surface of the hand, wrist, or ankle of any limbs, as placement with standard wired equipment allows.

These button-sized sensors are designed to provide continuous ECG, oxygen saturation (SpO₂), and skin temperature monitoring without the bulky wires and large adhesives that impact the most fragile infants.
実験的:Micro Preterm Infant

The Wireless MicroPremVitals Button Sensor System consists of three (3) sensors: a chest unit, a forehead unit, and a limb unit.

In this study, the MicroPremVitals Button forehead sensor will be mounted on the cerebral area of neonates at the level of the forehead. The chest unit will be mounted on the chest, between the nipples, or slightly below the nipple-line as placement allows. The limb unit will be mounted on the outer surface of the hand, wrist, or ankle of any limbs, as placement with standard wired equipment allows.

These button-sized sensors are designed to provide continuous ECG, oxygen saturation (SpO₂), and skin temperature monitoring without the bulky wires and large adhesives that impact the most fragile infants.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
HR Accuracy
時間枠:6 months
Comparison of heart rate measured by the Wireless MicroPremVitals Button Sensor System and the Philips IntelliVue MX800.
6 months
Oxygen Saturation Accuracy
時間枠:6 months
Comparison of SpO₂ measured by the Wireless MicroPremVitals Button Sensor System and the Philips IntelliVue MX800.
6 months
Skin Temperature Accuracy
時間枠:6 months
Comparison of skin temperature measured by the Wireless MicroPremVitals Button Sensor System and the Philips IntelliVue MX800.
6 months

二次結果の測定

結果測定
メジャーの説明
時間枠
Perspectives
時間枠:6 months
Clinician and parent/guardian perspectives on both the Wireless MicroPremVitals Button Sensor System and the wired vital sign monitoring system, will be assessed using a custom study questionnaire. The questionnaire includes Likert-scale items, multiple-choice questions, and open-ended responses evaluating usability, perceived safety, accuracy, comfort, and acceptability. Responses will be summarized descriptively by questionnaire item.
6 months

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Guilherme Sant'Anna, MD, PhD、The Research Institute of the McGill University Health Center

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2026年6月19日

一次修了 (推定)

2027年1月30日

研究の完了 (推定)

2027年3月30日

試験登録日

最初に提出

2026年5月5日

QC基準を満たした最初の提出物

2026年7月27日

最初の投稿 (実際)

2026年7月28日

学習記録の更新

投稿された最後の更新 (実際)

2026年7月28日

QC基準を満たした最後の更新が送信されました

2026年7月27日

最終確認日

2026年7月1日

詳しくは

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する