このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Wand STA vs SleeperOne for Pediatric Local Anesthesia (WASO-Kids) (WASO-Kids)

2026年8月4日 更新者:Victoria Katechi、National and Kapodistrian University of Athens

A Randomized Controlled Trial of the Acceptance of Two Computer-controlled Anaesthetic Delivery Systems in Paediatric Patients

This randomized, single-blind, split-mouth trial compares the acceptance of two computer-controlled local anaesthetic delivery (CCLAD) systems - Wand® STA and SleeperOne⑤ - in children aged 4-9 years undergoing comparable bilateral dental treatment. Each child receives local anaesthesia via both devices at separate visits, with pain, behaviour, heart rate, and oxygen saturation recorded at each session, to determine whether the two systems differ in child acceptance and physiological response.

調査の概要

研究の種類

介入

入学 (実際)

72

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 子

健康ボランティアの受け入れ

はい

説明

Inclusion Criteria:

  • Non-contributory medical history
  • At least one tooth requiring the same treatment on each side of the same jaw
  • Teeth on both sides with normal periodontium and no periapical pathology (confirmed radiographically)

Exclusion Criteria:

  • Age outside 4-9 years
  • History of psychiatric or developmental illness, or allergies
  • Use of analgesic medication in the preceding 12 hours
  • History of unpleasant dental treatment experiences

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:支持療法
  • 割り当て:ランダム化
  • 介入モデル:クロスオーバー割り当て
  • マスキング:独身

武器と介入

参加者グループ / アーム
介入・治療
実験的:Wand STA → SleeperOne
Participants received local anaesthesia using the Wand® STA computer-controlled delivery system at the first treatment session, followed by the SleeperOne⑤ system at the second session, for comparable bilateral dental treatment (split-mouth design).
A computer-controlled device that delivers local anesthetic through a pen-like handpiece at a constant, programmable flow rate and pressure. Incorporates pressure sensing to enable single-tooth anesthesia via periodontal ligament or infiltration delivery with minimal soft-tissue numbness. Articaine 1:200,000 was administered via this system at one of the two study visits, according to randomized sequence assignment.
A corded, pen-style computer-controlled device that delivers local anesthetic at a programmable injection speed across conventional, intraligamentary, and, in suitable cases, intraosseous techniques. Articaine 1:200,000 was administered via this system at one of the two study visits, according to randomized sequence assignment.
実験的:SleeperOne → Wand STA
Participants received local anaesthesia using the SleeperOne⑤ computer-controlled delivery system at the first treatment session, followed by the Wand® STA system at the second session, for comparable bilateral dental treatment (split-mouth design).
A computer-controlled device that delivers local anesthetic through a pen-like handpiece at a constant, programmable flow rate and pressure. Incorporates pressure sensing to enable single-tooth anesthesia via periodontal ligament or infiltration delivery with minimal soft-tissue numbness. Articaine 1:200,000 was administered via this system at one of the two study visits, according to randomized sequence assignment.
A corded, pen-style computer-controlled device that delivers local anesthetic at a programmable injection speed across conventional, intraligamentary, and, in suitable cases, intraosseous techniques. Articaine 1:200,000 was administered via this system at one of the two study visits, according to randomized sequence assignment.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Assessed at the end of each anaesthesia session, at both the first and second study visits
時間枠:Periprocedural
After the second anaesthetic injection, children rated their pain or discomfort using the Wong-Baker FACES Pain Rating Scale, administered by a trained examiner blinded to which device had been used. The scale presents six faces corresponding to scores of 0, 2, 4, 6, 8, and 10, where 0 indicates "no hurt" and 10 indicates "hurts worst"; higher scores indicate greater pain (a worse outcome). Children selected the face that best matched how they felt immediately after the injection
Periprocedural
Wong-Baker FACES Pain Score During Local Anaesthesia Injection
時間枠:Immediately following completion of the first local anaesthesia injection, prior to the start of dental treatment
After each anaesthetic injection, children rated their pain or discomfort using the Wong-Baker FACES Pain Rating Scale, administered by a trained examiner blinded to which device had been used. The scale presents six faces ranging from 0 (no hurt) to 10 (hurts worst), with children selecting the face that best matched how they felt. Scores were recorded once per session, after the first (Wand® STA or SleeperOne⑤, per randomized sequence) and again after the second anaesthetic delivery visit, allowing comparison both between devices and between sessions.
Immediately following completion of the first local anaesthesia injection, prior to the start of dental treatment

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Katechi、NKUA

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2025年5月5日

一次修了 (実際)

2026年1月30日

研究の完了 (実際)

2026年1月30日

試験登録日

最初に提出

2026年7月16日

QC基準を満たした最初の提出物

2026年8月4日

最初の投稿 (実際)

2026年8月10日

学習記録の更新

投稿された最後の更新 (実際)

2026年8月10日

QC基準を満たした最後の更新が送信されました

2026年8月4日

最終確認日

2026年7月1日

詳しくは

本研究に関する用語

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

米国で製造され、米国から輸出された製品。

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する