Effect of Prone Position on Continuous Noninvasive Hemoglobin Measurement
Does the Prone Position Affect Continuous Noninvasive Hemoglobin Measurement?
This prospective observational study aims to evaluate whether the prone position affects the agreement between noninvasive hemoglobin (SpHb) measurements and laboratory hemoglobin values in patients undergoing lumbar stabilization surgery under general anesthesia.
SpHb provides continuous, noninvasive monitoring of hemoglobin using multi-wavelength pulse CO-oximetry. However, its accuracy may be affected by changes in peripheral perfusion, hemodynamic status, and patient position. The prone position used during spine surgery may alter cardiovascular function and peripheral perfusion and may therefore influence SpHb measurements.
In this study, SpHb values obtained in the supine and prone positions will be compared with simultaneously obtained laboratory hemoglobin values. The study will also evaluate the ability of SpHb to follow changes in hemoglobin during surgery. The results may help clarify the clinical usefulness of continuous noninvasive hemoglobin monitoring during surgery performed in the prone position.
調査の概要
詳細な説明
This is a prospective, single-center observational study involving adult patients undergoing lumbar stabilization surgery under general anesthesia. Eligible patients will be older than 18 years and classified as American Society of Anesthesiologists (ASA) physical status I-III.
During surgery, noninvasive hemoglobin concentration (SpHb) will be monitored using a pulse CO-oximetry sensor placed on the finger as part of intraoperative monitoring. SpHb measurements will be compared with laboratory hemoglobin values obtained from blood gas analysis. Measurements obtained during supine and prone positioning will be evaluated to determine whether prone positioning affects the agreement between noninvasive and laboratory hemoglobin measurements.
Demographic and clinical characteristics, intraoperative hemodynamic variables, laboratory and blood gas parameters, estimated intraoperative blood loss, amount of transfused blood products, postoperative intensive care unit stay, and total hospital length of stay will also be recorded. The study will additionally assess the potential of SpHb for following intraoperative hemoglobin trends.
研究の種類
入学 (推定)
連絡先と場所
研究連絡先
- 名前:Sule Altuncu, MD
- 電話番号:02166063300
- メール:sancaktepeetikkurul@gmail.com
研究場所
-
-
Istanbul
-
Istanbul、Istanbul、トルコ(Türkiye)、34000
- 募集
- Sancaktepe Sehit Prof. Dr. Ilhan Varank Training and Research Hospital
-
コンタクト:
- Sule Altuncu, MD
- 電話番号:02166063300
- メール:sancaktepeetikkurul@gmail.com
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- Age 18 years or older
- American Society of Anesthesiologists (ASA) physical status I-III
- Scheduled to undergo lumbar stabilization surgery under general anesthesia
- Provision of written informed consent for participation in the study
Exclusion Criteria:
- Refusal to participate in the study
- ASA physical status IV-V
- Hemoglobin level <10 g/dL
- Presence of peripheral arterial disease
研究計画
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
介入・治療 |
|---|---|
|
Patients Undergoing Lumbar Stabilization Surgery
Adult patients undergoing lumbar stabilization surgery under general anesthesia.
Noninvasive hemoglobin (SpHb) and laboratory hemoglobin measurements will be obtained and compared during supine and prone positioning.
|
Prone positioning is performed as part of standard surgical care for lumbar stabilization surgery and is not assigned by the investigators.
The study will evaluate the association between prone positioning and the agreement between noninvasive hemoglobin (SpHb) measurements and simultaneously obtained laboratory hemoglobin values.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Agreement Between Noninvasive Hemoglobin (SpHb) and Laboratory Hemoglobin Measurements
時間枠:Intraoperative period, during supine and prone positioning on the day of surgery
|
Paired noninvasive hemoglobin (SpHb) and laboratory hemoglobin values will be obtained at corresponding intraoperative time points in the supine and prone positions.
The primary outcome is the agreement between SpHb and laboratory hemoglobin measurements and whether this agreement changes after positioning the patient prone.
|
Intraoperative period, during supine and prone positioning on the day of surgery
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Ability of SpHb to Track Intraoperative Hemoglobin Changes
時間枠:Intraoperative period on the day of surgery
|
Changes in noninvasive hemoglobin (SpHb) measurements over the intraoperative period will be compared with corresponding changes in laboratory hemoglobin values to evaluate the ability of SpHb to track the direction and magnitude of hemoglobin changes during surgery.
|
Intraoperative period on the day of surgery
|
協力者と研究者
捜査官
- 主任研究者:Altuncu、Şehit Prof. Dr. İlhan Varank Sancaktepe Training and Research Hospital
出版物と役立つリンク
一般刊行物
- Tang B, Yu X, Xu L, Zhu A, Zhang Y, Huang Y. Continuous noninvasive hemoglobin monitoring estimates timing for detecting anemia better than clinicians: a randomized controlled trial. BMC Anesthesiol. 2019 May 17;19(1):80. doi: 10.1186/s12871-019-0755-1.
- Berkow L, Rotolo S, Mirski E. Continuous noninvasive hemoglobin monitoring during complex spine surgery. Anesth Analg. 2011 Dec;113(6):1396-402. doi: 10.1213/ANE.0b013e318230b425. Epub 2011 Sep 29.
- Park SK, Hur C, Kim YW, Yoo S, Lim YJ, Kim JT. Noninvasive hemoglobin monitoring for maintaining hemoglobin concentration within the target range during major noncardiac surgery: A randomized controlled trial. J Clin Anesth. 2024 May;93:111326. doi: 10.1016/j.jclinane.2023.111326. Epub 2023 Nov 20.
- Adel A, Awada W, Abdelhamid B, Omar H, Abd El Dayem O, Hasanin A, Rady A. Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses. J Clin Monit Comput. 2018 Dec;32(6):1025-1031. doi: 10.1007/s10877-018-0101-z. Epub 2018 Jan 15.
- Erdogan Kayhan G, Colak YZ, Sanli M, Ucar M, Toprak HI. Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during liver transplantation. Minerva Anestesiol. 2017 May;83(5):485-492. doi: 10.23736/S0375-9393.17.11652-4. Epub 2017 Jan 20.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
追加の関連 MeSH 用語
その他の研究ID番号
- PRONE-NIHb-2026-486
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。