Effect of Prone Position on Continuous Noninvasive Hemoglobin Measurement
Does the Prone Position Affect Continuous Noninvasive Hemoglobin Measurement?
This prospective observational study aims to evaluate whether the prone position affects the agreement between noninvasive hemoglobin (SpHb) measurements and laboratory hemoglobin values in patients undergoing lumbar stabilization surgery under general anesthesia.
SpHb provides continuous, noninvasive monitoring of hemoglobin using multi-wavelength pulse CO-oximetry. However, its accuracy may be affected by changes in peripheral perfusion, hemodynamic status, and patient position. The prone position used during spine surgery may alter cardiovascular function and peripheral perfusion and may therefore influence SpHb measurements.
In this study, SpHb values obtained in the supine and prone positions will be compared with simultaneously obtained laboratory hemoglobin values. The study will also evaluate the ability of SpHb to follow changes in hemoglobin during surgery. The results may help clarify the clinical usefulness of continuous noninvasive hemoglobin monitoring during surgery performed in the prone position.
Studienübersicht
Status
Intervention / Behandlung
Detaillierte Beschreibung
This is a prospective, single-center observational study involving adult patients undergoing lumbar stabilization surgery under general anesthesia. Eligible patients will be older than 18 years and classified as American Society of Anesthesiologists (ASA) physical status I-III.
During surgery, noninvasive hemoglobin concentration (SpHb) will be monitored using a pulse CO-oximetry sensor placed on the finger as part of intraoperative monitoring. SpHb measurements will be compared with laboratory hemoglobin values obtained from blood gas analysis. Measurements obtained during supine and prone positioning will be evaluated to determine whether prone positioning affects the agreement between noninvasive and laboratory hemoglobin measurements.
Demographic and clinical characteristics, intraoperative hemodynamic variables, laboratory and blood gas parameters, estimated intraoperative blood loss, amount of transfused blood products, postoperative intensive care unit stay, and total hospital length of stay will also be recorded. The study will additionally assess the potential of SpHb for following intraoperative hemoglobin trends.
Studientyp
Einschreibung (Geschätzt)
Kontakte und Standorte
Studienkontakt
- Name: Sule Altuncu, MD
- Telefonnummer: 02166063300
- E-Mail: sancaktepeetikkurul@gmail.com
Studienorte
-
-
Istanbul
-
Istanbul, Istanbul, Türkei (türkiye), 34000
- Rekrutierung
- Sancaktepe Sehit Prof. Dr. Ilhan Varank Training and Research Hospital
-
Kontakt:
- Sule Altuncu, MD
- Telefonnummer: 02166063300
- E-Mail: sancaktepeetikkurul@gmail.com
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Probenahmeverfahren
Studienpopulation
Beschreibung
Inclusion Criteria:
- Age 18 years or older
- American Society of Anesthesiologists (ASA) physical status I-III
- Scheduled to undergo lumbar stabilization surgery under general anesthesia
- Provision of written informed consent for participation in the study
Exclusion Criteria:
- Refusal to participate in the study
- ASA physical status IV-V
- Hemoglobin level <10 g/dL
- Presence of peripheral arterial disease
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
Kohorten und Interventionen
Gruppe / Kohorte |
Intervention / Behandlung |
|---|---|
|
Patients Undergoing Lumbar Stabilization Surgery
Adult patients undergoing lumbar stabilization surgery under general anesthesia.
Noninvasive hemoglobin (SpHb) and laboratory hemoglobin measurements will be obtained and compared during supine and prone positioning.
|
Prone positioning is performed as part of standard surgical care for lumbar stabilization surgery and is not assigned by the investigators.
The study will evaluate the association between prone positioning and the agreement between noninvasive hemoglobin (SpHb) measurements and simultaneously obtained laboratory hemoglobin values.
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Agreement Between Noninvasive Hemoglobin (SpHb) and Laboratory Hemoglobin Measurements
Zeitfenster: Intraoperative period, during supine and prone positioning on the day of surgery
|
Paired noninvasive hemoglobin (SpHb) and laboratory hemoglobin values will be obtained at corresponding intraoperative time points in the supine and prone positions.
The primary outcome is the agreement between SpHb and laboratory hemoglobin measurements and whether this agreement changes after positioning the patient prone.
|
Intraoperative period, during supine and prone positioning on the day of surgery
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Ability of SpHb to Track Intraoperative Hemoglobin Changes
Zeitfenster: Intraoperative period on the day of surgery
|
Changes in noninvasive hemoglobin (SpHb) measurements over the intraoperative period will be compared with corresponding changes in laboratory hemoglobin values to evaluate the ability of SpHb to track the direction and magnitude of hemoglobin changes during surgery.
|
Intraoperative period on the day of surgery
|
Mitarbeiter und Ermittler
Ermittler
- Hauptermittler: Altuncu, Şehit Prof. Dr. İlhan Varank Sancaktepe Training and Research Hospital
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- Tang B, Yu X, Xu L, Zhu A, Zhang Y, Huang Y. Continuous noninvasive hemoglobin monitoring estimates timing for detecting anemia better than clinicians: a randomized controlled trial. BMC Anesthesiol. 2019 May 17;19(1):80. doi: 10.1186/s12871-019-0755-1.
- Berkow L, Rotolo S, Mirski E. Continuous noninvasive hemoglobin monitoring during complex spine surgery. Anesth Analg. 2011 Dec;113(6):1396-402. doi: 10.1213/ANE.0b013e318230b425. Epub 2011 Sep 29.
- Park SK, Hur C, Kim YW, Yoo S, Lim YJ, Kim JT. Noninvasive hemoglobin monitoring for maintaining hemoglobin concentration within the target range during major noncardiac surgery: A randomized controlled trial. J Clin Anesth. 2024 May;93:111326. doi: 10.1016/j.jclinane.2023.111326. Epub 2023 Nov 20.
- Adel A, Awada W, Abdelhamid B, Omar H, Abd El Dayem O, Hasanin A, Rady A. Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses. J Clin Monit Comput. 2018 Dec;32(6):1025-1031. doi: 10.1007/s10877-018-0101-z. Epub 2018 Jan 15.
- Erdogan Kayhan G, Colak YZ, Sanli M, Ucar M, Toprak HI. Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during liver transplantation. Minerva Anestesiol. 2017 May;83(5):485-492. doi: 10.23736/S0375-9393.17.11652-4. Epub 2017 Jan 20.
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Geschätzt)
Studienabschluss (Geschätzt)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- PRONE-NIHb-2026-486
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .