- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT07823569
Effect of Prone Position on Continuous Noninvasive Hemoglobin Measurement
Does the Prone Position Affect Continuous Noninvasive Hemoglobin Measurement?
This prospective observational study aims to evaluate whether the prone position affects the agreement between noninvasive hemoglobin (SpHb) measurements and laboratory hemoglobin values in patients undergoing lumbar stabilization surgery under general anesthesia.
SpHb provides continuous, noninvasive monitoring of hemoglobin using multi-wavelength pulse CO-oximetry. However, its accuracy may be affected by changes in peripheral perfusion, hemodynamic status, and patient position. The prone position used during spine surgery may alter cardiovascular function and peripheral perfusion and may therefore influence SpHb measurements.
In this study, SpHb values obtained in the supine and prone positions will be compared with simultaneously obtained laboratory hemoglobin values. The study will also evaluate the ability of SpHb to follow changes in hemoglobin during surgery. The results may help clarify the clinical usefulness of continuous noninvasive hemoglobin monitoring during surgery performed in the prone position.
Studieoversigt
Status
Intervention / Behandling
Detaljeret beskrivelse
This is a prospective, single-center observational study involving adult patients undergoing lumbar stabilization surgery under general anesthesia. Eligible patients will be older than 18 years and classified as American Society of Anesthesiologists (ASA) physical status I-III.
During surgery, noninvasive hemoglobin concentration (SpHb) will be monitored using a pulse CO-oximetry sensor placed on the finger as part of intraoperative monitoring. SpHb measurements will be compared with laboratory hemoglobin values obtained from blood gas analysis. Measurements obtained during supine and prone positioning will be evaluated to determine whether prone positioning affects the agreement between noninvasive and laboratory hemoglobin measurements.
Demographic and clinical characteristics, intraoperative hemodynamic variables, laboratory and blood gas parameters, estimated intraoperative blood loss, amount of transfused blood products, postoperative intensive care unit stay, and total hospital length of stay will also be recorded. The study will additionally assess the potential of SpHb for following intraoperative hemoglobin trends.
Undersøgelsestype
Tilmelding (Anslået)
Kontakter og lokationer
Studiekontakt
- Navn: Sule Altuncu, MD
- Telefonnummer: 02166063300
- E-mail: sancaktepeetikkurul@gmail.com
Studiesteder
-
-
Istanbul
-
Istanbul, Istanbul, Tyrkiet (Türkiye), 34000
- Rekruttering
- Sancaktepe Sehit Prof. Dr. Ilhan Varank Training and Research Hospital
-
Kontakt:
- Sule Altuncu, MD
- Telefonnummer: 02166063300
- E-mail: sancaktepeetikkurul@gmail.com
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Prøveudtagningsmetode
Studiebefolkning
Beskrivelse
Inclusion Criteria:
- Age 18 years or older
- American Society of Anesthesiologists (ASA) physical status I-III
- Scheduled to undergo lumbar stabilization surgery under general anesthesia
- Provision of written informed consent for participation in the study
Exclusion Criteria:
- Refusal to participate in the study
- ASA physical status IV-V
- Hemoglobin level <10 g/dL
- Presence of peripheral arterial disease
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
Kohorter og interventioner
Gruppe / kohorte |
Intervention / Behandling |
|---|---|
|
Patients Undergoing Lumbar Stabilization Surgery
Adult patients undergoing lumbar stabilization surgery under general anesthesia.
Noninvasive hemoglobin (SpHb) and laboratory hemoglobin measurements will be obtained and compared during supine and prone positioning.
|
Prone positioning is performed as part of standard surgical care for lumbar stabilization surgery and is not assigned by the investigators.
The study will evaluate the association between prone positioning and the agreement between noninvasive hemoglobin (SpHb) measurements and simultaneously obtained laboratory hemoglobin values.
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Agreement Between Noninvasive Hemoglobin (SpHb) and Laboratory Hemoglobin Measurements
Tidsramme: Intraoperative period, during supine and prone positioning on the day of surgery
|
Paired noninvasive hemoglobin (SpHb) and laboratory hemoglobin values will be obtained at corresponding intraoperative time points in the supine and prone positions.
The primary outcome is the agreement between SpHb and laboratory hemoglobin measurements and whether this agreement changes after positioning the patient prone.
|
Intraoperative period, during supine and prone positioning on the day of surgery
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Ability of SpHb to Track Intraoperative Hemoglobin Changes
Tidsramme: Intraoperative period on the day of surgery
|
Changes in noninvasive hemoglobin (SpHb) measurements over the intraoperative period will be compared with corresponding changes in laboratory hemoglobin values to evaluate the ability of SpHb to track the direction and magnitude of hemoglobin changes during surgery.
|
Intraoperative period on the day of surgery
|
Samarbejdspartnere og efterforskere
Efterforskere
- Ledende efterforsker: Altuncu, Şehit Prof. Dr. İlhan Varank Sancaktepe Training and Research Hospital
Publikationer og nyttige links
Generelle publikationer
- Tang B, Yu X, Xu L, Zhu A, Zhang Y, Huang Y. Continuous noninvasive hemoglobin monitoring estimates timing for detecting anemia better than clinicians: a randomized controlled trial. BMC Anesthesiol. 2019 May 17;19(1):80. doi: 10.1186/s12871-019-0755-1.
- Berkow L, Rotolo S, Mirski E. Continuous noninvasive hemoglobin monitoring during complex spine surgery. Anesth Analg. 2011 Dec;113(6):1396-402. doi: 10.1213/ANE.0b013e318230b425. Epub 2011 Sep 29.
- Park SK, Hur C, Kim YW, Yoo S, Lim YJ, Kim JT. Noninvasive hemoglobin monitoring for maintaining hemoglobin concentration within the target range during major noncardiac surgery: A randomized controlled trial. J Clin Anesth. 2024 May;93:111326. doi: 10.1016/j.jclinane.2023.111326. Epub 2023 Nov 20.
- Adel A, Awada W, Abdelhamid B, Omar H, Abd El Dayem O, Hasanin A, Rady A. Accuracy and trending of non-invasive hemoglobin measurement during different volume and perfusion statuses. J Clin Monit Comput. 2018 Dec;32(6):1025-1031. doi: 10.1007/s10877-018-0101-z. Epub 2018 Jan 15.
- Erdogan Kayhan G, Colak YZ, Sanli M, Ucar M, Toprak HI. Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during liver transplantation. Minerva Anestesiol. 2017 May;83(5):485-492. doi: 10.23736/S0375-9393.17.11652-4. Epub 2017 Jan 20.
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Anslået)
Studieafslutning (Anslået)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- PRONE-NIHb-2026-486
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .