이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Ultrasound-guided Catheterization of the Axillary Vein

2016년 5월 8일 업데이트: Tomasz Czarnik, MD PhD, Uniwersytecki Szpital Kliniczny w Opolu

Real-time Ultrasound-guided Catheterization of the Axillary Vein in the Intensive Care Unit

The central venous catheterization (central line placement) is the common procedure performed in the intensive care unit. This procedure is performed by percutaneous puncture of so called 'the central vein' and than advancement of the catheter over the guidewire (Seldinger technique). The tip of the catheter is left in the superior vena cava in the vicinity of the right atrium of the heart. Central veins are large veins in the human body passing the blood into the heart.

Typical, clinical indications for the central line placement in the intensive care unit are hemodynamic monitoring, volume monitoring, administration of medications, long-term total parenteral nutrition, access for renal replacement therapy, difficult peripheral catheterization.

There are two methods of the central venous catheterization in terms of visualization. First and older is the blind technique. The operator is locating the anatomical landmarks and then performing the entire procedure blindly by percutaneous puncture. This is called the landmark technique. Second and new is the ultrasound-guided technique. The operator is locating the vein using ultrasonography and then performing the entire procedure under ultrasonographic visualization. The real time ultrasound-guided central venous catheterization became the standard of care in recent years mainly because of safety issues (is regarded as safer than landmark technique)

The catheterization of the axillary vein is not popular procedure in daily clinical practice. But it can be reasonable and safe alternative to others, typically performed central venous catheterizations like the internal jugular vein and the subclavian vein catheterizations.

The main intention of this study is to assess usefulness and safety of the real time ultrasound guided axillary vein catheterization in mechanically ventilated patients admitted to the intensive care unit.

연구 개요

상태

완전한

정황

개입 / 치료

연구 유형

중재적

등록 (실제)

202

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

      • Opole, 폴란드, 45-418
        • Department of Anesthesiology and Intensive Care, Publiczny Samodzielny Zaklad Opieki Zdrowotnej Wojewodzkie Centrum Medyczne w Opolu

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 이상 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • mechanically ventilated intensive care patients with clinical indications for central venous line placement

Exclusion Criteria:

  • trauma and hematoma at the catheterization site
  • history of multiple central venous catheterizations (three or more)
  • chest wall deformities
  • major blood coagulation disorders
  • history of thoracic surgery
  • anatomical abnormalities at the catheterization site
  • infection at the catheterization site
  • age less than 18 years
  • lack of patients or closest relatives consent

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 지지 요법
  • 할당: 해당 없음
  • 중재 모델: 단일 그룹 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: axillary vein catheterization
central venous catheter placement into the axillary vein under ultrasound guidance
catheterization of the axillary vein under ultrasound guidance

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
to define venipuncture, catheterization and entire procedure success rates
기간: 24 hours
the venipuncture is defined as perforation of the axillary vein by the needle, the catheterization is defined as the placement of catheter in the final position, the entire procedure success rate is defined as the placement of catheter in the final position without early complications (assessed within 24 hours time frame)
24 hours
to assess the erly complication rate of ultrasound-guided axillary vein catheterization
기간: 24 hours
pneumothorax, puncture of the axillary artery, hemothorax, heart perforation, catheter malposition, significant arrhythmias, air embolism
24 hours

2차 결과 측정

결과 측정
측정값 설명
기간
to assess the correlation between entire procedure success rate and the side of catheterization
기간: 2 years
the left axillary vein or the right axillary vein
2 years
to assess the correlation between patients weight, height and depth, diameter of the axillary vein
기간: 2 years
the depth and diameter of the axillary vein is measured by ultrasonography
2 years

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 수석 연구원: Tomasz Czarnik, MD, Department of Anesthesiology and Intensive Care, Publiczny Samodzielny Zaklad Opieki Zdrowotnej Wojewodzkie Centrum Medyczne w Opolu

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작

2012년 12월 1일

기본 완료 (실제)

2015년 6월 1일

연구 완료 (실제)

2015년 6월 1일

연구 등록 날짜

최초 제출

2013년 8월 4일

QC 기준을 충족하는 최초 제출

2013년 8월 6일

처음 게시됨 (추정)

2013년 8월 9일

연구 기록 업데이트

마지막 업데이트 게시됨 (추정)

2016년 5월 10일

QC 기준을 충족하는 마지막 업데이트 제출

2016년 5월 8일

마지막으로 확인됨

2016년 5월 1일

추가 정보

이 연구와 관련된 용어

추가 관련 MeSH 약관

기타 연구 ID 번호

  • Axillary-US-guided-1
  • Axillary-1 (기타 식별자: PS ZOZ Wojewodzkie Centrum Medyczne w Opolu)

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

ultrasound에 대한 임상 시험

구독하다